Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
York heat pump efficiency: 179 outdoor models compared
York has 179 heat pump outdoor models certified with this refrigerant group, in 65,299 AHRI-certified combinations. They are also sold as CHAMPION, CHAMPION HEATING AND COOLING, Coleman, EVCON, FRASER-JOHNSTON, GUARDIAN, JOHNSON CONTROLS, Luxaire and 2 more names. Each model is compared with models of the same size and duct type, so the scores below do not depend on which sizes York makes. Ranks are among manufacturers with a QMID on file and at least 10 scored models.
New to heat pump ratings? The Simple view explains them in plain words →
ManufacturerData as of updated · sources
- Outdoor models
- 179
- AHRI certifications
- 65,299
- Efficiency index
- 51%
- Typical model vs same-size, same-type peers (137 models)
- Meet CEE 2025
- 26.3%
- 47 models
How York compares with comparable models
- York
- Middle half of its models
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Beats comparable models | Rank | Raw median |
|---|---|---|---|
| Efficiency index137 models scored | 51% | 21st of 27 | — |
| COP at 5°F139 models scored | 69% | 5th of 27 | 2.20 |
| Capacity retention at 5°F139 models scored | 50% | 18th of 27 | 69% |
| HSPF2154 models scored | 37% | 23rd of 27 | 7.7 |
| SEER2154 models scored | 38% | 24th of 27 | 15.2 |
| EER2154 models scored | 57% | 9th of 27 | 11.0 |
| Heating capacity at 5°F139 models scored | 49% | 17th of 27 | 24,200 Btu/h |
Standards met
| Standard | Share | Models |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 26.3% | 47 |
| CEE 2026 Tier 1 (Split ASHP) | 26.3% | 47 |
| CEE Advanced Tier (Split ASHP) | 0.6% | 1 |
| Xcel Energy Colorado cold-climate ASHP (2025) | 25.7% | 46 |
| DOE Cold Climate Heat Pump Challenge | 0.6% | 1 |
| ENERGY STAR Cold Climate | 2.2% | 4 |
Sizes and duct types offered
- York (median, middle 50%, 10th–90th)
- All models of the group
Source: AHRI Directory · as of
| Size and duct type | Models | Index | COP@5°F | HSPF2 | SEER2 |
|---|---|---|---|---|---|
| Ducted, up to 1.5 tons | 8 | 42% | 86% | 14% | 19% |
| Ducted, 2 tons | 17 | 47% | 71% | 36% | 39% |
| Ducted, 2.5–3 tons | 53 | 51% | 76% | 31% | 36% |
| Ducted, 3.5–4.5 tons | 71 | 60% | 80% | 44% | 46% |
| Ducted, 5 tons and up | 19 | 50% | 59% | 33% | 40% |
| Non-ducted, up to 1.5 tons | 9 | 25% | 17% | 27% | 21% |
| Non-ducted, 2 tons | 2 | 41% | 34% | 56% | 37% |
| Non-ducted, 2.5–3 tons | 6 | 54% | 33% | 60% | 45% |
| Non-ducted, 3.5–4.5 tons | 5 | 46% | 43% | 43% | 31% |
| Non-ducted, 5 tons and up | 2 | 46% | 49% | 61% | 38% |
Every York model in the market
- York models
- Ducted median by size
- Non-ducted median by size
- Every model at each size (width = count)
- Standard threshold
Show the data as a table
| Duct type, size | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ducted, 0.5 tons | 175 | 1.70 | 1.85 | 1.90 | 2.10 | 2.26 |
| Ducted, 1 ton | 340 | 1.85 | 1.90 | 2.00 | 2.40 | 2.65 |
| Ducted, 1.5 tons | 789 | 1.75 | 1.85 | 2.00 | 2.20 | 2.55 |
| Ducted, 2 tons | 782 | 1.73 | 1.80 | 2.00 | 2.10 | 2.33 |
| Ducted, 2.5 tons | 735 | 1.71 | 1.80 | 1.90 | 2.09 | 2.48 |
| Ducted, 3 tons | 652 | 1.68 | 1.70 | 1.90 | 2.06 | 2.36 |
| Ducted, 3.5 tons | 641 | 1.61 | 1.80 | 1.95 | 2.20 | 2.50 |
| Ducted, 4 tons | 367 | 1.70 | 1.80 | 1.91 | 2.02 | 2.52 |
| Ducted, 4.5 tons | 544 | 1.70 | 1.80 | 1.91 | 2.08 | 2.34 |
| Ducted, 5 tons | 25 | 1.80 | 1.80 | 1.90 | 1.90 | 2.15 |
| Non-ducted, 0.5 tons | 717 | 1.75 | 1.81 | 1.97 | 2.10 | 2.19 |
| Non-ducted, 1 ton | 1,064 | 1.75 | 1.80 | 1.90 | 2.07 | 2.25 |
| Non-ducted, 1.5 tons | 886 | 1.80 | 1.80 | 1.87 | 2.07 | 2.21 |
| Non-ducted, 2 tons | 564 | 1.80 | 1.80 | 1.83 | 2.04 | 2.21 |
| Non-ducted, 2.5 tons | 275 | 1.80 | 1.81 | 1.84 | 1.86 | 2.03 |
| Non-ducted, 3 tons | 502 | 1.80 | 1.80 | 1.90 | 2.00 | 2.09 |
| Non-ducted, 3.5 tons | 70 | 1.82 | 1.83 | 1.90 | 2.00 | 2.28 |
| Non-ducted, 4 tons | 263 | 1.80 | 1.80 | 1.98 | 2.00 | 2.10 |
| Non-ducted, 4.5 tons | 103 | 1.77 | 1.77 | 1.80 | 1.97 | 2.02 |
| Non-ducted, 5 tons | 29 | 1.98 | 2.00 | 2.10 | 2.30 | 2.47 |
Source: AHRI Directory · as of
Top York models
Cold-climate picks
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | Btu/h @5°F | SEER2 | Meets | Combos | AHRI ref. | Compared with | Score |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1HMH72B341YORKwith indoor coil CM36B36+TDR and furnace TM9V120D20MP12 | 2.5 tons31,600 Btu/h · Ducted | 100% | 2.94 | 8.5 | 25,400 | 17.0 | CEE 25CEE 26CEE AdvXcelDOEES CC | 13,786 | 211628039 | Ducted, 2.5–3 tons | 83.8 |
| 2RHP15048B21GUARDIANwith ducted air handler L(E,G)M60A4Also sold as Champion Heating and Cooling THF2B48T21 | 4 tons45,000 Btu/h · Ducted | 83% | 3.70 | 8.1 | 37,800 | 15.5 | CEE 25CEE 26Xcel | 117 | 213612208 | Ducted, 3.5–4.5 tons | 77.7 |
| 3RHP14348B21GUARDIANwith ducted air handler AEL+D(A,C,E)60B44+TDR | 3.5 tons42,000 Btu/h · Ducted | 87% | 3.49 | 7.8 | 38,000 | 14.3 | None | 569 | 212912442 | Ducted, 3.5–4.5 tons | 77.1 |
| 4YH2F48TB21YORKwith ducted air handler L(E,G)M48F4 | 3.5 tons44,500 Btu/h · Ducted | 82% | 3.63 | 8.1 | 37,400 | 15.2 | CEE 25CEE 26Xcel | 1,449 | 214442672 | Ducted, 3.5–4.5 tons | 76.9 |
| 5YZV48B21YORKwith indoor coil XAMC48HE3N1+CC and furnace TM9V100C16MP12 | 3.5 tons43,500 Btu/h · Ducted | 82% | 2.14 | 9.0 | 36,200 | 19.0 | CEE 25CEE 26Xcel | 54 | 211207031 | Ducted, 3.5–4.5 tons | 76.9 |
All-around best
| # · Outdoor model | Size · type | Cap. 5/47 | COP@5°F | HSPF2 | SEER2 | EER2 | Meets | Combos | AHRI ref. | Compared with | Score | Heating half | Cooling half | Cold-climate score |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1YZV48B21YORKwith indoor coil XAMC48HE3N1+CC and furnace TM9V100C16MP12 | 3.5 tons43,500 Btu/h · Ducted | 82% | 2.14 | 9.0 | 19.0 | 12.0 | CEE 25CEE 26Xcel | 54 | 211207031 | Ducted, 3.5–4.5 tons | 83.7 | 76.9 | 90.6 | 76.9 |
| 2YZT48B21YORKwith ducted air handler AEL+D(A,C,E)60D44+TDR | 4 tons45,500 Btu/h · Ducted | 69% | 3.11 | 8.5 | 17.3 | 12.4 | CEE 25CEE 26Xcel | 947 | 212912471 | Ducted, 3.5–4.5 tons | 82.3 | 75.5 | 89.1 | 71.1 |
| 3YZV60B21YORKwith ducted air handler JHVVD60HE4C2N1+CC | 4.5 tons52,500 Btu/h · Ducted | 77% | 2.24 | 8.5 | 19.0 | 12.0 | CEE 25CEE 26Xcel | 22 | 211010174 | Ducted, 3.5–4.5 tons | 81.6 | 72.6 | 90.6 | 72.6 |
| 4YMSJYH036BAAND-1YORKwith ducted air handler YMSJXH036BAAN--5 | 4 tons47,000 Btu/h · Ducted | 70% | 2.00 | 9.5 | 18.5 | 12.0 | CEE 25CEE 26Xcel | 1 | 217734525 | Ducted, 3.5–4.5 tons | 81.4 | 74.0 | 88.7 | 74.0 |
| 5YMSJYH060BAAND-1YORKwith ducted air handler YMSJXH060BAAN--5 | 4.5 tons52,000 Btu/h · Ducted | 70% | 2.02 | 9.5 | 18.0 | 11.7 | CEE 25CEE 26Xcel | 1 | 217734527 | Ducted, 3.5–4.5 tons | 79.3 | 75.8 | 82.8 | 75.8 |
Best model on each rating
| Rating | Model | Value | Compared with | Beats | AHRI ref. |
|---|---|---|---|---|---|
| COP at 5°F | THE2B42T21 | 3.44 | Ducted, 2.5–3 tons | 100% | 214606372 |
| Capacity retention at 5°F | THE2B18S21 | 149% | Ducted, up to 1.5 tons | 100% | 210857054 |
| HSPF2 | YVAHP048B21S*Also sold as Coleman CVAHP048B21S | 10.0 | Ducted, 3.5–4.5 tons | 98% | 203994974 |
| SEER2 | YMKE60BNJMFMO-X | 18.0 | Ducted, 5 tons and up | 96% | 205739196 |
| EER2 | YVAHP048B21S*Also sold as Coleman CVAHP048B21S | 16.7 | Non-ducted, 3.5–4.5 tons | 100% | 203994968 |
| Heating capacity at 5°F | DHS18CMB22S | 21,800 Btu/h | Non-ducted, up to 1.5 tons | 99% | 207616532 |
York size class by size class: cold-climate and all-around
| Size and duct type | Cold-climate pickCold-climate score, best model | All-around bestAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 59.7(50 is the typical model of its size class)THF2B18S21with ducted air handler AE(D,N,U)+CM24D24+TDR7 of 8 models qualify · AHRI 214606310 | 57.1(50 is the typical model of its size class)YH2F18SB21with ducted air handler AE*S+CM24C24+TDR7 of 7 models have all five ratings · AHRI 216437405 |
| Ducted, 2 tons | 60.6(50 is the typical model of its size class)THE2B24T21with ducted air handler AX242BTA10 of 16 models qualify · AHRI 211634285 | 77.1(50 is the typical model of its size class)YMSJYH024BAAND-1with ducted air handler YMSJXH024BAAN--517 of 17 models have all five ratings · AHRI 217734524 |
| Ducted, 2.5–3 tons | 83.8(50 is the typical model of its size class)HMH72B341with indoor coil CM36B36+TDR and furnace TM9V120D20MP1222 of 53 models qualify · AHRI 211628039 | 76.1(50 is the typical model of its size class)YMSJYH048BAAND-1with ducted air handler YMSJXH048BAAN--534 of 51 models have all five ratings · AHRI 217734526 |
| Ducted, 3.5–4.5 tons | 77.7(50 is the typical model of its size class)RHP15048B21with ducted air handler L(E,G)M60A4Also sold as Champion Heating and Cooling THF2B48T2124 of 72 models qualify · AHRI 213612208 | 83.7(50 is the typical model of its size class)YZV48B21with indoor coil XAMC48HE3N1+CC and furnace TM9V100C16MP1248 of 73 models have all five ratings · AHRI 211207031 |
| Ducted, 5 tons and up | 70.2(50 is the typical model of its size class)YMKE60BNJMFMO-X1 of 19 models qualify · AHRI 205739196 | 75.1(50 is the typical model of its size class)YMKE60BNJMFMO-X12 of 20 models have all five ratings · AHRI 205739196 |
| Non-ducted, up to 1.5 tons | 64.2(50 is the typical model of its size class)DHS18CMB22S5 of 9 models qualify · AHRI 207616532 | 50.6(50 is the typical model of its size class)DHS18CMB22S9 of 9 models have all five ratings · AHRI 207616532 |
| Non-ducted, 2 tons | 66.1(50 is the typical model of its size class)DHS24CMB22S1 of 2 models qualify · AHRI 207616534 | 55.4(50 is the typical model of its size class)DHS24CMB22S2 of 2 models have all five ratings · AHRI 207616534 |
| Non-ducted, 2.5–3 tons | 60.8(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models qualify · AHRI 203994967 | 74.6(50 is the typical model of its size class)YVAHP036B21S*Also sold as Coleman CVAHP036B21S5 of 6 models have all five ratings · AHRI 203994967 |
| Non-ducted, 3.5–4.5 tons | 31.6(50 is the typical model of its size class)DHS42CMB22S1 of 5 models qualify · AHRI 207616540 | 67.0(50 is the typical model of its size class)YVAHP048B21S*Also sold as Coleman CVAHP048B21S3 of 5 models have all five ratings · AHRI 203994968 |
| Non-ducted, 5 tons and up | None on this board (0 of 2 models qualify) | 68.5(50 is the typical model of its size class)YVAHP060B21S*2 of 2 models have all five ratings · AHRI 203994964 |
Newest York certifications
| Outdoor model | Size · type | COP@5°F | Cap. 5/47 | HSPF2 | SEER2 | Meets | Combos | AHRI ref. |
|---|---|---|---|---|---|---|---|---|
| YMSJYH060BAAND-1YORKwith ducted air handler YMSJXH060BAAN--5 | 4.5 tons52,000 Btu/h · Ducted | 2.02 | 70% | 9.5 | 18.0 | CEE 25CEE 26Xcel | 1 | 217734527 |
| YMSJYH048BAAND-1YORKwith ducted air handler YMSJXH048BAAN--5 | 3 tons34,200 Btu/h · Ducted | 2.02 | 62% | 9.5 | 19.0 | CEE 25CEE 26 | 1 | 217734526 |
| YMSJYH036BAAND-1YORKwith ducted air handler YMSJXH036BAAN--5 | 4 tons47,000 Btu/h · Ducted | 2.00 | 70% | 9.5 | 18.5 | CEE 25CEE 26Xcel | 1 | 217734525 |
| YMSJYH024BAAND-1YORKwith ducted air handler YMSJXH024BAAN--5 | 2 tons24,000 Btu/h · Ducted | 2.00 | 73% | 9.5 | 20.0 | CEE 25CEE 26Xcel | 1 | 217734524 |
| YMKE60BNJMFMO-YYork | 5 tons57,000 Btu/h · Ducted | 1.40 | 38% | 6.7 | 13.4 | None | 1 | 217269219 |
Compare York
York includes these brand names as listed in AHRI: CHAMPION, CHAMPION HEATING AND COOLING, Coleman, EVCON, FRASER-JOHNSTON, GUARDIAN, JOHNSON CONTROLS, Luxaire, TEMPMASTER, YORK BY JOHNSON CONTROLS, York. Standards are checked against published thresholds; program rules beyond ratings are not checked.