Skip to content

1HVAC vs Bosch heat pumps

Measured against models of the same size and duct type, Bosch scores higher on 4 of the 6 ratings. 1HVAC has 87 outdoor models, Bosch has 50 outdoor models. 1HVAC has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
1HVAC and Bosch on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Bosch scores higher on 4 of the 6 ratings.
  • 1HVAC
  • Bosch
  • Other ranked manufacturers
1HVACBosch

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
Rating1HVACBosch
Efficiency index54%median —65%median — · 3rd ranked
COP at 5°F45%median 1.9056%median 2.00 · 11th ranked
Capacity retention at 5°F63% (higher)median 77%61% (higher)median 73% · 6th ranked
HSPF261%median 9.269%median 9.3 · 4th ranked
SEER259%median 18.070%median 19.2 · 2nd ranked
EER243%median 11.058%median 11.7 · 8th ranked
Heating capacity at 5°F62% (higher)median 23,400 Btu/h56% (higher)median 20,000 Btu/h · 11th ranked
Outdoor models8750
AHRI certifications1,1901,560

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
Standard1HVACBosch
CEE 2025 Tier 1 (Split ASHP)64.4%56 models76%38 models
CEE 2026 Tier 1 (Split ASHP)59.8%52 models76%38 models
CEE Advanced Tier (Split ASHP)1.1%1 models2%1 models
Xcel Energy Colorado cold-climate ASHP (2025)55.2%48 models64%32 models
DOE Cold Climate Heat Pump Challenge1.1%1 models2%1 models
ENERGY STAR Cold Climate41.4%36 models30%15 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • 1HVAC
  • Bosch
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct type1HVACBosch
Ducted, up to 1.5 tons9 · index 57%11 · index 65%
Ducted, 2 tons10 · index 58%9 · index 72%
Ducted, 2.5 to 3 tons18 · index 54%12 · index 58%
Ducted, 3.5 to 4.5 tons22 · index 53%7 · index 69%
Ducted, 5 tons and upNone5 · index 60%
Non-ducted, up to 1.5 tons21 · index 56%11 · index 68%
Non-ducted, 2 tons6 · index 52%2 · index 82%
Non-ducted, 2.5 to 3 tons17 · index 54%10 · index 62%
Non-ducted, 3.5 to 4.5 tons8 · index 47%4 · index 58%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct type1HVACCold-climate score, best modelBoschCold-climate score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class) (higher)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM8 of 9 models qualify · AHRI 21343322975.7(50 is the typical model of its size class)BMS500-AAS009-1CSXHBwith ducted air handler BMS500-AAU009-1AHDXB10 of 11 models qualify · AHRI 204014467
Ducted, 2 tons79.6(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB9 of 9 models qualify · AHRI 20782552282.5(50 is the typical model of its size class) (higher)BMS500-AAS024-1CSXHBwith ducted air handler BMS500-AAU024-1AHDXB8 of 8 models qualify · AHRI 204014470
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB14 of 19 models qualify · AHRI 21085730189.0(50 is the typical model of its size class) (higher)BOVD-36HDN1-M20Gwith indoor coil D(A,C,E)36C44+TDR and furnace BGH96M100C5B5 of 12 models qualify · AHRI 215375438
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB14 of 22 models qualify · AHRI 21085730288.4(50 is the typical model of its size class) (higher)BOVA-60HDN1-M20Gwith ducted air handler L(E,G)M48G45 of 8 models qualify · AHRI 212675690
Ducted, 5 tons and upNo models in this size class70.2(50 is the typical model of its size class)BRB-60HWD1N1-M19Also listed as BRBA-60HWD1N1-M182 of 5 models qualify · AHRI 202680590
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC11 of 21 models qualify · AHRI 21085729489.8(50 is the typical model of its size class)BMS500-AAS009-1CSXRCwith ductless indoor unit BMS500-AAU006-1AHWXC7 of 11 models qualify · AHRI 207759993
Non-ducted, 2 tons86.3(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB3 of 6 models qualify · AHRI 20782552587.1(50 is the typical model of its size class) (higher)BMS500-AAS024-1CSXHCwith ductless indoor unit BMS500-AAU024-1AHCXC2 of 2 models qualify · AHRI 207760018
Non-ducted, 2.5 to 3 tons80.2(50 is the typical model of its size class)ACIQ-36Z-HH-M4B9 of 17 models qualify · AHRI 20782557080.2(50 is the typical model of its size class)BMS500-AAM036-1CSXHC3 of 10 models qualify · AHRI 207760039
Non-ducted, 3.5 to 4.5 tons76.8(50 is the typical model of its size class) (higher)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 8 models qualify · AHRI 21085730676.5(50 is the typical model of its size class)BMS500-AAM048-1CSXHC1 of 4 models qualify · AHRI 207760042

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct type1HVACAll-around score, best modelBoschAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB9 of 9 models have all five ratings · AHRI 20782551985.4(50 is the typical model of its size class)BMS500-AAS009-1CSXHCwith ducted air handler BMS500-AAU009-1AHDXB11 of 11 models have all five ratings · AHRI 207760001
Ducted, 2 tons80.2(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB10 of 10 models have all five ratings · AHRI 20782552287.9(50 is the typical model of its size class) (higher)BOVA-36HDN1-M20Gwith ducted air handler AE(D,N,U)+CM36B34+TDR9 of 9 models have all five ratings · AHRI 213885831
Ducted, 2.5 to 3 tons75.5(50 is the typical model of its size class)HVH837GKA2*with indoor coil EN(A,D,W)4X60L24**+WALLCON and furnace *95CSU0802120A18 of 18 models have all five ratings · AHRI 21047087885.6(50 is the typical model of its size class) (higher)BOVD-36HDN1-M20Gwith indoor coil D(A,C,E)36C44+TDR and furnace BGH96M100C5B11 of 12 models have all five ratings · AHRI 215375438
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)ACIQ-48Z-HH-M5B21 of 21 models have all five ratings · AHRI 20782557488.6(50 is the typical model of its size class) (higher)BOVA-60HDN1-M20Gwith ducted air handler L(E,G)M48G46 of 7 models have all five ratings · AHRI 212675690
Ducted, 5 tons and up42.0(50 is the typical model of its size class)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 21343322375.5(50 is the typical model of its size class) (higher)BRB-60HWD1N1-M19Also listed as BRBA-60HWD1N1-M185 of 5 models have all five ratings · AHRI 202680590
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC21 of 21 models have all five ratings · AHRI 21085729492.3(50 is the typical model of its size class)BMS500-AAS009-1CSXRCwith ductless indoor unit BMS500-AAU006-1AHWXC11 of 11 models have all five ratings · AHRI 207759993
Non-ducted, 2 tons84.9(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB6 of 6 models have all five ratings · AHRI 20782551584.9(50 is the typical model of its size class)BMS500-AAS024-1CSXHCwith ductless indoor unit BMS500-AAU024-1AHWXC2 of 2 models have all five ratings · AHRI 207759997
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class)ACIQ-36Z-HH-M4B15 of 17 models have all five ratings · AHRI 20782557083.4(50 is the typical model of its size class)BMS500-AAM036-1CSXHC8 of 10 models have all five ratings · AHRI 207760039
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class)ACIQ-48Z-HH-M5B8 of 8 models have all five ratings · AHRI 20782557378.0(50 is the typical model of its size class)BMS500-AAM048-1CSXHC3 of 4 models have all five ratings · AHRI 207760042

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
Rating1HVACBosch
COP at 5°Fbeats 92% · 2.21ACIQ-24ZPL-HP230BNon-ducted, 2 tonsbeats 99% · 3.03BOVD-36HDN1-M20GDucted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 99% · 144%SC-09ZPL-HP230Non-ducted, up to 1.5 tonsbeats 100% · 126%BOVD-36HDN1-M20GDucted, 2.5 to 3 tons
HSPF2beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5 to 4.5 tonsbeats 99% · 13.6BMS500-AAS009-1CSXRCNon-ducted, up to 1.5 tons
SEER2beats 99% · 20.9ACIQ-48Z-HH-M5BDucted, 3.5 to 4.5 tonsbeats 99% · 20.9BMS500-AAM048-1CSXHCDucted, 3.5 to 4.5 tons
EER2beats 99% · 16.6SC-09ZPL-HP230Non-ducted, up to 1.5 tonsbeats 98% · 16.2BMS500-AAS009-1CSXHCNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5 to 4.5 tonsbeats 96% · 20,000 Btu/hBMS500-AAM018-1CSXHCNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
1HVAC vs Bosch: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • 1HVAC (median, middle 50%)
  • Bosch (median, middle 50%)
Heating capacity, % of its 47°F maximum70%63%COP at maximum capacity1.902.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
1HVAC: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
1HVAC, 47°F58100%100%100%100%100%
1HVAC, 17°F5865%69%77%85%91%
1HVAC, 5°F5856%58%70%78%83%
1HVAC: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
1HVAC, 47°F582.792.953.183.353.48
1HVAC, 17°F582.022.092.222.32.42
1HVAC, 5°F581.81.811.922.06
Bosch: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Bosch, 47°F39100%100%100%100%100%
Bosch, 17°F3966%68%73%78%83%
Bosch, 5°F3955%57%63%69%80%
Bosch: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Bosch, 47°F392.852.923.243.433.56
Bosch, 17°F391.872.072.222.332.42
Bosch, 5°F391.821.8922.062.19

Source: NEEP ccASHP list · as of