1HVAC vs KADEN heat pumps

Measured against models of the same size and duct type, KADEN scores higher on 4 of the 6 ratings. 1HVAC has 87 outdoor models, KADEN has 24 outdoor models. 1HVAC and KADEN have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
1HVAC and KADEN on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, KADEN scores higher on 4 of the 6 ratings.
  • 1HVAC
  • KADEN
  • Other ranked manufacturers
1HVACKADEN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
Rating1HVACKADEN
Efficiency index54%median —58%median —
COP at 5°F45%median 1.9053%median 2.00
Capacity retention at 5°F63% (higher)median 77%41% (higher)median 65%
HSPF261%median 9.269%median 9.3
SEER259%median 18.074%median 19.3
EER243%median 11.049%median 10.9
Heating capacity at 5°F62% (higher)median 23,400 Btu/h45% (higher)median 18,250 Btu/h
Outdoor models8724
AHRI certifications1,19037

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
Standard1HVACKADEN
CEE 2025 Tier 1 (Split ASHP)64.4%56 models66.7%16 models
CEE 2026 Tier 1 (Split ASHP)59.8%52 models54.2%13 models
CEE Advanced Tier (Split ASHP)1.1%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)55.2%48 models25%6 models
DOE Cold Climate Heat Pump Challenge1.1%1 models0%0 models
ENERGY STAR Cold Climate41.4%36 models25%6 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • 1HVAC
  • KADEN
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct type1HVACKADEN
Ducted, up to 1.5 tons9 · index 57%3 · index 43%
Ducted, 2 tons10 · index 58%2 · index 52%
Ducted, 2.5 to 3 tons18 · index 54%6 · index 52%
Ducted, 3.5 to 4.5 tons22 · index 53%4 · index 55%
Ducted, 5 tons and upNone2 · index 42%
Non-ducted, up to 1.5 tons21 · index 56%7 · index 73%
Non-ducted, 2 tons6 · index 52%1 · index 79%
Non-ducted, 2.5 to 3 tons17 · index 54%2 · index 70%
Non-ducted, 3.5 to 4.5 tons8 · index 47%2 · index 48%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct type1HVACCold-climate score, best modelKADENCold-climate score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class) (higher)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM8 of 9 models qualify · AHRI 21343322952.6(50 is the typical model of its size class)KO-PS218HP-2AAMA1 of 3 models qualify · AHRI 211793561
Ducted, 2 tons79.6(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB9 of 9 models qualify · AHRI 20782552263.2(50 is the typical model of its size class)KO-UUS24HP-2AAMAwith ducted air handler KI-UUS24AHP-2AAMAAlso listed as KO-UUX24HP-2AAMA2 of 2 models qualify · AHRI 211793549
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB14 of 19 models qualify · AHRI 210857301None on this board (0 of 6 models qualify)
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB14 of 22 models qualify · AHRI 210857302None on this board (0 of 4 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 2 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC11 of 21 models qualify · AHRI 21085729489.8(50 is the typical model of its size class)KO-PSX06HP-2AAMAwith ductless indoor unit KI-PSX06WM-2AAMA2 of 7 models qualify · AHRI 213265556
Non-ducted, 2 tons86.3(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB3 of 6 models qualify · AHRI 20782552562.5(50 is the typical model of its size class)KO-PSX24HP-2AAMAwith ductless indoor unit KI-PSX24WM-2AAMA1 of 1 models qualify · AHRI 211793559
Non-ducted, 2.5 to 3 tons80.2(50 is the typical model of its size class)ACIQ-36Z-HH-M4B9 of 17 models qualify · AHRI 207825570None on this board (0 of 2 models qualify)
Non-ducted, 3.5 to 4.5 tons76.8(50 is the typical model of its size class)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 8 models qualify · AHRI 210857306None on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct type1HVACAll-around score, best modelKADENAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB9 of 9 models have all five ratings · AHRI 20782551959.8(50 is the typical model of its size class)KO-PS218HP-2AAMA3 of 3 models have all five ratings · AHRI 211793561
Ducted, 2 tons80.2(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB10 of 10 models have all five ratings · AHRI 20782552251.9(50 is the typical model of its size class)KO-UUS24HP-2AAMAwith ducted air handler KI-UUS24AHP-2AAMAAlso listed as KO-UUX24HP-2AAMA2 of 2 models have all five ratings · AHRI 211793549
Ducted, 2.5 to 3 tons75.5(50 is the typical model of its size class) (higher)HVH837GKA2*with indoor coil EN(A,D,W)4X60L24**+WALLCON and furnace *95CSU0802120A18 of 18 models have all five ratings · AHRI 21047087875.4(50 is the typical model of its size class)KO-PS327HP-2AAMA6 of 6 models have all five ratings · AHRI 211793564
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B21 of 21 models have all five ratings · AHRI 20782557463.5(50 is the typical model of its size class)KO-PS548HP-2AAMA4 of 4 models have all five ratings · AHRI 211793568
Ducted, 5 tons and up42.0(50 is the typical model of its size class) (higher)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 21343322341.9(50 is the typical model of its size class)KO-UUS60HP-2AAMAwith ducted air handler KI-UUS60AHU-2AAMAAlso listed as KO-UUX60HP-2AAMA2 of 2 models have all five ratings · AHRI 211793553
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC21 of 21 models have all five ratings · AHRI 21085729492.3(50 is the typical model of its size class)KO-PSX06HP-2AAMAwith ductless indoor unit KI-PSX06WM-2AAMA7 of 7 models have all five ratings · AHRI 213265556
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB6 of 6 models have all five ratings · AHRI 20782551578.6(50 is the typical model of its size class)KO-PSX24HP-2AAMAwith ductless indoor unit KI-PSX24WM-2AAMA1 of 1 models have all five ratings · AHRI 211793559
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M4B15 of 17 models have all five ratings · AHRI 20782557078.9(50 is the typical model of its size class)KO-PS327HP-2AAMA2 of 2 models have all five ratings · AHRI 211793563
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B8 of 8 models have all five ratings · AHRI 20782557356.0(50 is the typical model of its size class)KO-PS548HP-2AAMA2 of 2 models have all five ratings · AHRI 211793567

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
Rating1HVACKADEN
COP at 5°Fbeats 92% · 2.21ACIQ-24ZPL-HP230BNon-ducted, 2 tonsbeats 97% · 2.39KO-PSX12HP-2AAMANon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 144%SC-09ZPL-HP230Non-ducted, up to 1.5 tonsbeats 93% · 107%KO-PSX06HP-2AAMANon-ducted, up to 1.5 tons
HSPF2beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5 to 4.5 tonsbeats 99% · 13.6KO-PSX06HP-2AAMANon-ducted, up to 1.5 tons
SEER2beats 99% · 20.9ACIQ-48Z-HH-M5BDucted, 3.5 to 4.5 tonsbeats 99% · 24.6KO-PS327HP-2AAMANon-ducted, 2.5 to 3 tons
EER2beats 99% · 16.6SC-09ZPL-HP230Non-ducted, up to 1.5 tonsbeats 97% · 14.0KO-PSX24HP-2AAMANon-ducted, 2 tons
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5 to 4.5 tonsbeats 80% · 13,100 Btu/hKO-PSX18HP-2AAMANon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
1HVAC vs KADEN: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • 1HVAC (median, middle 50%)
  • KADEN (median, middle 50%)
Heating capacity, % of its 47°F maximum70%58%COP at maximum capacity1.902.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
1HVAC: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
1HVAC, 47°F58100%100%100%100%100%
1HVAC, 17°F5865%69%77%85%91%
1HVAC, 5°F5856%58%70%78%83%
1HVAC: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
1HVAC, 47°F582.792.953.183.353.48
1HVAC, 17°F582.022.092.222.32.42
1HVAC, 5°F581.81.811.922.06
KADEN: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
KADEN, 47°F22100%100%100%100%100%
KADEN, 17°F2262%64%68%72%74%
KADEN, 5°F2253%55%58%63%65%
KADEN: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
KADEN, 47°F223.043.063.243.513.57
KADEN, 17°F222.12.182.242.532.71
KADEN, 5°F221.811.922.12.29

Source: NEEP ccASHP list · as of