1HVAC vs Star Air Kontrol heat pumps
Measured against models of the same size and duct type, 1HVAC scores higher on 4 of the 6 ratings. 1HVAC has 87 outdoor models, Star Air Kontrol has 55 outdoor models. 1HVAC and Star Air Kontrol have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- 1HVAC
- Star Air Kontrol
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | 1HVAC | Star Air Kontrol |
|---|---|---|
| Efficiency index | 54% (higher)median — | 51% (higher)median — |
| COP at 5°F | 45%median 1.90 | 57%median 1.99 |
| Capacity retention at 5°F | 63% (higher)median 77% | 36% (higher)median 66% |
| HSPF2 | 61%median 9.2 | 61%median 9.2 |
| SEER2 | 59% (higher)median 18.0 | 57% (higher)median 19.2 |
| EER2 | 43% (higher)median 11.0 | 41% (higher)median 10.6 |
| Heating capacity at 5°F | 62% (higher)median 23,400 Btu/h | 45% (higher)median 17,700 Btu/h |
| Outdoor models | 87 | 55 |
| AHRI certifications | 1,190 | 70 |
Share of models meeting each standard
| Standard | 1HVAC | Star Air Kontrol |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 64.4%56 models | 50.9%28 models |
| CEE 2026 Tier 1 (Split ASHP) | 59.8%52 models | 43.6%24 models |
| CEE Advanced Tier (Split ASHP) | 1.1%1 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 55.2%48 models | 23.6%13 models |
| DOE Cold Climate Heat Pump Challenge | 1.1%1 models | 0%0 models |
| ENERGY STAR Cold Climate | 41.4%36 models | 20%11 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- 1HVAC
- Star Air Kontrol
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | 1HVAC | Star Air Kontrol |
|---|---|---|
| Ducted, up to 1.5 tons | 9 · index 57% | 4 · index 59% |
| Ducted, 2 tons | 10 · index 58% | 3 · index 68% |
| Ducted, 2.5 to 3 tons | 18 · index 54% | 6 · index 53% |
| Ducted, 3.5 to 4.5 tons | 22 · index 53% | 7 · index 53% |
| Ducted, 5 tons and up | None | 3 · index 51% |
| Non-ducted, up to 1.5 tons | 21 · index 56% | 18 · index 53% |
| Non-ducted, 2 tons | 6 · index 52% | 6 · index 52% |
| Non-ducted, 2.5 to 3 tons | 17 · index 54% | 7 · index 43% |
| Non-ducted, 3.5 to 4.5 tons | 8 · index 47% | 6 · index 41% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | 1HVACCold-climate score, best model | Star Air KontrolCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 87.0(50 is the typical model of its size class) (higher)ACIQ-18-HPBwith ducted air handler ACIQ-18W-WM8 of 9 models qualify · AHRI 213433229 | 68.2(50 is the typical model of its size class)SAK-12-DTMS/220Vwith ducted air handler SAK-12-DTMS/220V2 of 4 models qualify · AHRI 213081463 |
| Ducted, 2 tons | 79.6(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB9 of 9 models qualify · AHRI 207825522 | 80.6(50 is the typical model of its size class) (higher)SAK-24-DTMS/220Vwith ducted air handler SAK-24-DTMS/220V2 of 3 models qualify · AHRI 211726522 |
| Ducted, 2.5 to 3 tons | 80.0(50 is the typical model of its size class) (higher)ACIQ-36ZPL-HP230Bwith ducted air handler ACIQ-36CD-HH-MB14 of 19 models qualify · AHRI 210857301 | 57.6(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*1 of 6 models qualify · AHRI 211726669 |
| Ducted, 3.5 to 4.5 tons | 86.5(50 is the typical model of its size class)ACIQ-48ZPL-HP230Bwith ducted air handler ACIQ-48CD-HH-MB14 of 22 models qualify · AHRI 210857302 | None on this board (0 of 7 models qualify) |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 3 models qualify) |
| Non-ducted, up to 1.5 tons | 89.8(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC11 of 21 models qualify · AHRI 210857294 | 85.5(50 is the typical model of its size class)SAK-09-OC/220Vwith ductless indoor unit SAK-09-OC/220V4 of 18 models qualify · AHRI 213279897 |
| Non-ducted, 2 tons | 86.3(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24FM-HH-MB3 of 6 models qualify · AHRI 207825525 | 75.6(50 is the typical model of its size class)SAK-24CONS/220Vwith ductless indoor unit SAK-24CONS/220V3 of 6 models qualify · AHRI 213279887 |
| Non-ducted, 2.5 to 3 tons | 80.2(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M4B9 of 17 models qualify · AHRI 207825570 | 51.5(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*1 of 7 models qualify · AHRI 211726668 |
| Non-ducted, 3.5 to 4.5 tons | 76.8(50 is the typical model of its size class) (higher)ACIQ-60ZPL-HP230Bwith ductless indoor unit ACIQ-60FM-HH-MB5 of 8 models qualify · AHRI 210857306 | 56.3(50 is the typical model of its size class)SAK-48CONS/220Vwith ductless indoor unit SAK-48CONS/220V1 of 6 models qualify · AHRI 213279889 |
All-around best
| Size and duct type | 1HVACAll-around score, best model | Star Air KontrolAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.4(50 is the typical model of its size class) (higher)ACIQ-09ZPL-HP230Bwith ducted air handler ACIQ-09CD-HH-MB9 of 9 models have all five ratings · AHRI 207825519 | 78.8(50 is the typical model of its size class)SAK-18-DTMS/220Vwith ducted air handler SAK-18-DTMS/220V4 of 4 models have all five ratings · AHRI 211726521 |
| Ducted, 2 tons | 80.2(50 is the typical model of its size class)ACIQ-24ZPL-HP230Bwith ducted air handler ACIQ-24CD-HH-MB10 of 10 models have all five ratings · AHRI 207825522 | 84.0(50 is the typical model of its size class) (higher)SAK-24-DTMS/220Vwith ducted air handler SAK-24-DTMS/220V2 of 3 models have all five ratings · AHRI 211726522 |
| Ducted, 2.5 to 3 tons | 75.5(50 is the typical model of its size class) (higher)HVH837GKA2*with indoor coil EN(A,D,W)4X60L24**+WALLCON and furnace *95CSU0802120A18 of 18 models have all five ratings · AHRI 210470878 | 71.7(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*4 of 6 models have all five ratings · AHRI 211726669 |
| Ducted, 3.5 to 4.5 tons | 82.1(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B21 of 21 models have all five ratings · AHRI 207825574 | 63.5(50 is the typical model of its size class)SAK-48-21MUZ/220(OUT)*4 of 7 models have all five ratings · AHRI 211726673 |
| Ducted, 5 tons and up | 42.0(50 is the typical model of its size class)ACIQ-60-EHPBwith ducted air handler ACIQ-60AHB1 of 1 models have all five ratings · AHRI 213433223 | 57.2(50 is the typical model of its size class) (higher)SAK-60-DTMS/220V*with ducted air handler SAK-60-DTMS/220V3 of 3 models have all five ratings · AHRI 211726674 |
| Non-ducted, up to 1.5 tons | 92.3(50 is the typical model of its size class) (higher)ACIQ-06ZPL-HP230Bwith ductless indoor unit ACIQ-06W-HH-MC21 of 21 models have all five ratings · AHRI 210857294 | 77.7(50 is the typical model of its size class)SAK-09-OC/220Vwith ductless indoor unit SAK-09-OC/220V18 of 18 models have all five ratings · AHRI 213279897 |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class) (higher)ACIQ-24ZPL-HP230Bwith ductless indoor unit ACIQ-24W-HH-MB6 of 6 models have all five ratings · AHRI 207825515 | 72.9(50 is the typical model of its size class)SAK-24CONS/220Vwith ductless indoor unit SAK-24CONS/220V6 of 6 models have all five ratings · AHRI 213279887 |
| Non-ducted, 2.5 to 3 tons | 83.4(50 is the typical model of its size class) (higher)ACIQ-36Z-HH-M4B15 of 17 models have all five ratings · AHRI 207825570 | 68.0(50 is the typical model of its size class)SAK-27-22MUZ/220(OUT)*6 of 7 models have all five ratings · AHRI 211726668 |
| Non-ducted, 3.5 to 4.5 tons | 78.0(50 is the typical model of its size class) (higher)ACIQ-48Z-HH-M5B8 of 8 models have all five ratings · AHRI 207825573 | 48.3(50 is the typical model of its size class)SAK-48-21MUZ/220(OUT)*6 of 6 models have all five ratings · AHRI 211726672 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | 1HVAC | Star Air Kontrol |
|---|---|---|
| COP at 5°F | beats 92% · 2.21ACIQ-24ZPL-HP230BNon-ducted, 2 tons | beats 96% · 2.38SAK-18-24MS/220Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 99% · 144%SC-09ZPL-HP230Non-ducted, up to 1.5 tons | beats 72% · 59%SAK-60-DTMS/220VDucted, 5 tons and up |
| HSPF2 | beats 99% · 10.3ACIQ-48ZPL-HP230BDucted, 3.5 to 4.5 tons | beats 98% · 11.2SAK-24-DTMS/220VDucted, 2 tons |
| SEER2 | beats 99% · 20.9ACIQ-48Z-HH-M5BDucted, 3.5 to 4.5 tons | beats 98% · 21.0SAK-27-22MUZ/220(OUT)*Ducted, 2.5 to 3 tons |
| EER2 | beats 99% · 16.6SC-09ZPL-HP230Non-ducted, up to 1.5 tons | beats 85% · 12.5SAK-24-DTMS/220VDucted, 2 tons |
| Heating capacity at 5°F | beats 99% · 56,500 Btu/hACIQ-60ZPL-HP230BNon-ducted, 3.5 to 4.5 tons | beats 80% · 13,100 Btu/hSAK-18-OC/220VNon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- 1HVAC (median, middle 50%)
- Star Air Kontrol (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,710 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,710 | 55% | 58% | 66% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,710 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,710 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,710 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| 1HVAC, 47°F | 58 | 100% | 100% | 100% | 100% | 100% |
| 1HVAC, 17°F | 58 | 65% | 69% | 77% | 85% | 91% |
| 1HVAC, 5°F | 58 | 56% | 58% | 70% | 78% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| 1HVAC, 47°F | 58 | 2.79 | 2.95 | 3.18 | 3.35 | 3.48 |
| 1HVAC, 17°F | 58 | 2.02 | 2.09 | 2.22 | 2.3 | 2.42 |
| 1HVAC, 5°F | 58 | 1.8 | 1.81 | 1.9 | 2 | 2.06 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Star Air Kontrol, 47°F | 44 | 100% | 100% | 100% | 100% | 100% |
| Star Air Kontrol, 17°F | 44 | 59% | 64% | 68% | 71% | 73% |
| Star Air Kontrol, 5°F | 44 | 51% | 55% | 58% | 63% | 67% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Star Air Kontrol, 47°F | 44 | 2.76 | 2.91 | 3.06 | 3.27 | 3.52 |
| Star Air Kontrol, 17°F | 44 | 2.05 | 2.13 | 2.25 | 2.39 | 2.47 |
| Star Air Kontrol, 5°F | 44 | 1.8 | 1.9 | 2 | 2.17 | 2.29 |
Source: NEEP ccASHP list · as of