Both views use the same certified data. This device remembers your choice.
ACC vs ARCTIC KING heat pumps
Measured against models of the same size and duct type, ACC scores higher on 5 of the 6 ratings. ACC has 5 outdoor models, ARCTIC KING has 5 outdoor models. ACC and ARCTIC KING have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ACC
- ARCTIC KING
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ACC | ARCTIC KING |
|---|---|---|
| Efficiency index | 54% (higher)median — | 41% (higher)median — |
| COP at 5°F | 69% (higher)median 2.08 | 64% (higher)median 2.01 |
| Capacity retention at 5°F | 75% (higher)median 59% | 41% (higher)median 69% |
| HSPF2 | 45% (higher)median 8.4 | 29% (higher)median 9.0 |
| SEER2 | 27% (higher)median 15.4 | 23% (higher)median 17.0 |
| EER2 | 12%median 8.5 | 27%median 9.0 |
| Heating capacity at 5°F | 77% (higher)median 35,600 Btu/h | 42% (higher)median 17,321 Btu/h |
| Outdoor models | 5 | 5 |
| AHRI certifications | 6 | 5 |
Share of models meeting each standard
| Standard | ACC | ARCTIC KING |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 20%1 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 20%1 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 20%1 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ACC
- ARCTIC KING
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ACC | ARCTIC KING |
|---|---|---|
| Ducted, 2.5 to 3 tons | 1 · index — | None |
| Ducted, 3.5 to 4.5 tons | 1 · index — | None |
| Ducted, 5 tons and up | 1 · index 54% | None |
| Non-ducted, 2.5 to 3 tons | 2 · index — | 1 · index — |
| Non-ducted, 2 tons | None | 2 · index 41% |
| Non-ducted, 3.5 to 4.5 tons | None | 2 · index — |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ACCCold-climate score, best model | ARCTIC KINGCold-climate score, best model |
|---|---|---|
| Ducted, 2.5 to 3 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, 2 tons | No models in this size class | 56.8(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ductless indoor unit MSAG11D-23HRFN1-MU0W1 of 2 models qualify · AHRI 207821945 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | ACCAll-around score, best model | ARCTIC KINGAll-around score, best model |
|---|---|---|
| Ducted, 2.5 to 3 tons | None on this board (0 of 1 models have all five ratings) | No models in this size class |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 1 models have all five ratings) | No models in this size class |
| Ducted, 5 tons and up | 54.3(50 is the typical model of its size class)MSH603E18MCAAwith ducted air handler MST363E18ADAA1 of 1 models have all five ratings · AHRI 203991110 | No models in this size class |
| Non-ducted, 2 tons | No models in this size class | 67.4(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ductless indoor unit MSAG11D-23HRFN1-MU0W2 of 2 models have all five ratings · AHRI 207821945 |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 2 models have all five ratings) | None on this board (0 of 1 models have all five ratings) |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 2 models have all five ratings) |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ACC | ARCTIC KING |
|---|---|---|
| COP at 5°F | beats 69% · 2.08MSH603E18MCAADucted, 5 tons and up | beats 97% · 2.22MOD33-24HFN1-MT0WNon-ducted, 2 tons |
| Capacity retention at 5°F | beats 72% · 59%MSH603E18MCAADucted, 5 tons and up | beats 49% · 75%MOD33-24HFN1-MT0WNon-ducted, 2 tons |
| HSPF2 | beats 81% · 9.3MSH483E18MCAADucted, 3.5 to 4.5 tons | beats 57% · 9.3MOD30U-36HFN1-MNon-ducted, 2.5 to 3 tons |
| SEER2 | beats 54% · 15.4MSH603E18MCAADucted, 5 tons and up | beats 66% · 21.0MOD33-24HFN1-MT0WNon-ducted, 2 tons |
| EER2 | beats 16% · 8.6MSH363E23MCAANon-ducted, 2.5 to 3 tons | beats 85% · 13.0MOD33-24HFN1-MT0WNon-ducted, 2 tons |
| Heating capacity at 5°F | beats 76% · 35,600 Btu/hMSH603E18MCAADucted, 5 tons and up | beats 58% · 19,542 Btu/hMOD33-24HFN1-MT0WNon-ducted, 2 tons |