Both views use the same certified data. This device remembers your choice.
ACC vs Prime heat pumps
Measured against models of the same size and duct type, ACC scores higher on 6 of the 6 ratings. ACC has 5 outdoor models, Prime has 5 outdoor models. ACC and Prime have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ACC
- Prime
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ACC | Prime |
|---|---|---|
| Efficiency index | 54% (higher)median — | 25% (higher)median — |
| COP at 5°F | 69% (higher)median 2.08 | 19% (higher)median 1.80 |
| Capacity retention at 5°F | 75% (higher)median 59% | 15% (higher)median 58% |
| HSPF2 | 45% (higher)median 8.4 | 13% (higher)median 8.0 |
| SEER2 | 27% (higher)median 15.4 | 12% (higher)median 17.0 |
| EER2 | 12% (higher)median 8.5 | 5% (higher)median 8.5 |
| Heating capacity at 5°F | 77% (higher)median 35,600 Btu/h | 31% (higher)median 21,000 Btu/h |
| Outdoor models | 5 | 5 |
| AHRI certifications | 6 | 5 |
Share of models meeting each standard
| Standard | ACC | Prime |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 0%0 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 0%0 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ACC
- Prime
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ACC | Prime |
|---|---|---|
| Ducted, 2.5 to 3 tons | 1 · index — | None |
| Ducted, 3.5 to 4.5 tons | 1 · index — | None |
| Ducted, 5 tons and up | 1 · index 54% | None |
| Non-ducted, 2.5 to 3 tons | 2 · index — | 1 · index 25% |
| Non-ducted, up to 1.5 tons | None | 3 · index — |
| Non-ducted, 2 tons | None | 1 · index — |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ACCCold-climate score, best model | PrimeCold-climate score, best model |
|---|---|---|
| Ducted, 2.5 to 3 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 3 models qualify) |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 2 models qualify) | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | ACCAll-around score, best model | PrimeAll-around score, best model |
|---|---|---|
| Ducted, 2.5 to 3 tons | None on this board (0 of 1 models have all five ratings) | No models in this size class |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 1 models have all five ratings) | No models in this size class |
| Ducted, 5 tons and up | 54.3(50 is the typical model of its size class)MSH603E18MCAAwith ducted air handler MST363E18ADAA1 of 1 models have all five ratings · AHRI 203991110 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | None on this board (0 of 3 models have all five ratings) |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 1 models have all five ratings) |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 2 models have all five ratings) | 24.9(50 is the typical model of its size class)EMPRN362-Vwith ductless indoor unit CMPRN362-V1 of 1 models have all five ratings · AHRI 214061906 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ACC | Prime |
|---|---|---|
| COP at 5°F | beats 69% · 2.08MSH603E18MCAADucted, 5 tons and up | beats 19% · 1.80EMPRN362-VNon-ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 72% · 59%MSH603E18MCAADucted, 5 tons and up | beats 15% · 58%EMPRN362-VNon-ducted, 2.5 to 3 tons |
| HSPF2 | beats 81% · 9.3MSH483E18MCAADucted, 3.5 to 4.5 tons | beats 26% · 8.5EMPRN362-VNon-ducted, 2.5 to 3 tons |
| SEER2 | beats 54% · 15.4MSH603E18MCAADucted, 5 tons and up | beats 35% · 19.0EMPRN362-VNon-ducted, 2.5 to 3 tons |
| EER2 | beats 16% · 8.6MSH363E23MCAANon-ducted, 2.5 to 3 tons | beats 21% · 9.0EMPRN362-VNon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 76% · 35,600 Btu/hMSH603E18MCAADucted, 5 tons and up | beats 30% · 21,000 Btu/hEMPRN362-VNon-ducted, 2.5 to 3 tons |