ACD vs HAXXAIR heat pumps

Measured against models of the same size and duct type, ACD scores higher on 5 of the 6 ratings. ACD has 25 outdoor models, HAXXAIR has 26 outdoor models. ACD and HAXXAIR have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ACD and HAXXAIR on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ACD scores higher on 5 of the 6 ratings.
  • ACD
  • HAXXAIR
  • Other ranked manufacturers
ACDHAXXAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingACDHAXXAIR
Efficiency index52% (higher)median —49% (higher)median —
COP at 5°F38%median 1.8248%median 1.87
Capacity retention at 5°F70% (higher)median 78%59% (higher)median 77%
HSPF247% (higher)median 9.046% (higher)median 8.7
SEER253% (higher)median 20.049% (higher)median 18.5
EER251% (higher)median 12.045% (higher)median 11.4
Heating capacity at 5°F68% (higher)median 21,600 Btu/h53% (higher)median 17,450 Btu/h
Outdoor models2526
AHRI certifications5142

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardACDHAXXAIR
CEE 2025 Tier 1 (Split ASHP)88%22 models73.1%19 models
CEE 2026 Tier 1 (Split ASHP)84%21 models69.2%18 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)88%22 models65.4%17 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate64%16 models46.2%12 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • ACD
  • HAXXAIR
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeACDHAXXAIR
Ducted, up to 1.5 tons1 · index 32%3 · index 50%
Ducted, 2 tons2 · index 53%3 · index 58%
Ducted, 2.5 to 3 tons3 · index 52%3 · index 70%
Ducted, 3.5 to 4.5 tons1 · index 63%3 · index 58%
Non-ducted, up to 1.5 tons11 · index 52%12 · index 42%
Non-ducted, 2 tons5 · index 55%5 · index 50%
Non-ducted, 2.5 to 3 tons6 · index 56%4 · index 40%
Non-ducted, 3.5 to 4.5 tons1 · index 19%1 · index 40%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeACDCold-climate score, best modelHAXXAIRCold-climate score, best model
Ducted, up to 1.5 tons36.3(50 is the typical model of its size class)MPD18KCH21SB-O1 of 1 models qualify · AHRI 21053413254.9(50 is the typical model of its size class) (higher)HVHSC-18T2Dwith ducted air handler HAHS-18T2D3 of 3 models qualify · AHRI 205921368
Ducted, 2 tons50.3(50 is the typical model of its size class)MPD24KCH21SB-O1 of 1 models qualify · AHRI 21053413365.2(50 is the typical model of its size class) (higher)HVHSC-24T2Dwith ducted air handler HAHS-24T2D3 of 3 models qualify · AHRI 214855367
Ducted, 2.5 to 3 tons55.4(50 is the typical model of its size class)FXD-ACD36with ducted air handler AH2364 of 4 models qualify · AHRI 20749790278.4(50 is the typical model of its size class) (higher)HVHSC-36T2Dwith ducted air handler HAHS-36T2D3 of 3 models qualify · AHRI 214855368
Ducted, 3.5 to 4.5 tons58.3(50 is the typical model of its size class)FXD-ACD60with ducted air handler AH2481 of 1 models qualify · AHRI 20749790373.3(50 is the typical model of its size class) (higher)HVHD-48E2D2with ducted air handler DC61A44-245R2 of 3 models qualify · AHRI 214264495
Non-ducted, up to 1.5 tons80.8(50 is the typical model of its size class) (higher)UHD09KCH38SB-Owith ductless indoor unit UHD09KCH38SB-I10 of 11 models qualify · AHRI 20240983274.0(50 is the typical model of its size class)HVHSC-18T2Dwith ductless indoor unit HAHC-18T2D6 of 12 models qualify · AHRI 205921367
Non-ducted, 2 tons77.3(50 is the typical model of its size class) (higher)MPD24KCH21SB-O4 of 5 models qualify · AHRI 21053412873.4(50 is the typical model of its size class)HVHSC-24T2Dwith ductless indoor unit HAH-24T2D4 of 5 models qualify · AHRI 214855369
Non-ducted, 2.5 to 3 tons74.7(50 is the typical model of its size class)MPD42KCH21SB-O6 of 6 models qualify · AHRI 21053413178.2(50 is the typical model of its size class) (higher)HVHSC-36T2Dwith ductless indoor unit HAH-36T2D2 of 4 models qualify · AHRI 214855370
Non-ducted, 3.5 to 4.5 tons31.6(50 is the typical model of its size class)MUD42KCH23S-O1 of 1 models qualify · AHRI 20642858741.8(50 is the typical model of its size class) (higher)HVHM-42T2D1 of 1 models qualify · AHRI 212396481

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeACDAll-around score, best modelHAXXAIRAll-around score, best model
Ducted, up to 1.5 tons31.8(50 is the typical model of its size class)MPD18KCH21SB-O1 of 1 models have all five ratings · AHRI 21053413251.0(50 is the typical model of its size class) (higher)HVHSC-18T2Dwith ducted air handler HAHS-18T2D3 of 3 models have all five ratings · AHRI 205921368
Ducted, 2 tons60.8(50 is the typical model of its size class)FXD-ACD36with ducted air handler AH2242 of 2 models have all five ratings · AHRI 20749790171.7(50 is the typical model of its size class) (higher)HVHM-24T2D3 of 3 models have all five ratings · AHRI 204032224
Ducted, 2.5 to 3 tons53.0(50 is the typical model of its size class)MPD30KCH21SB-O3 of 3 models have all five ratings · AHRI 21053413478.7(50 is the typical model of its size class) (higher)HVHM-36T2D3 of 3 models have all five ratings · AHRI 204032225
Ducted, 3.5 to 4.5 tons63.3(50 is the typical model of its size class)FXD-ACD60with ducted air handler AH2481 of 1 models have all five ratings · AHRI 20749790368.7(50 is the typical model of its size class) (higher)HVHD-48E2D2with ducted air handler DC61A44-245R3 of 3 models have all five ratings · AHRI 214264495
Non-ducted, up to 1.5 tons89.1(50 is the typical model of its size class) (higher)UHD09KCH38SB-Owith ductless indoor unit UHD09KCH38SB-I11 of 11 models have all five ratings · AHRI 20240983270.8(50 is the typical model of its size class)HVHSC-18T2Dwith ductless indoor unit HAH-18T2D12 of 12 models have all five ratings · AHRI 214855372
Non-ducted, 2 tons77.1(50 is the typical model of its size class) (higher)UHD24KCH22S-Owith ductless indoor unit UHD24KCH22S-I5 of 5 models have all five ratings · AHRI 20213278968.5(50 is the typical model of its size class)HVHM-24T2D5 of 5 models have all five ratings · AHRI 204198639
Non-ducted, 2.5 to 3 tons70.9(50 is the typical model of its size class) (higher)MPD42KCH21SB-O6 of 6 models have all five ratings · AHRI 21053413170.2(50 is the typical model of its size class)HVHM-36T2D4 of 4 models have all five ratings · AHRI 204100526
Non-ducted, 3.5 to 4.5 tons18.7(50 is the typical model of its size class)MUD42KCH23S-O1 of 1 models have all five ratings · AHRI 20642858744.4(50 is the typical model of its size class) (higher)HVHM-42T2D1 of 1 models have all five ratings · AHRI 212510994

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingACDHAXXAIR
COP at 5°Fbeats 89% · 2.21MPD18KCH21SB-ONon-ducted, up to 1.5 tonsbeats 96% · 2.28HVHSC-36T2DNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 99% · 144%UHD09KCH38SB-ONon-ducted, up to 1.5 tonsbeats 99% · 113%HVHM-36T2DNon-ducted, 2.5 to 3 tons
HSPF2beats 88% · 11.0UHD09KCH38SB-ONon-ducted, up to 1.5 tonsbeats 83% · 9.5HVHD-36E2D2Ducted, 2.5 to 3 tons
SEER2beats 95% · 27.0UHD09KCH38SB-ONon-ducted, up to 1.5 tonsbeats 96% · 21.0HVHM-24T2DDucted, 2 tons
EER2beats 99% · 16.6UHD09KCH38SB-ONon-ducted, up to 1.5 tonsbeats 84% · 12.5HVHM-36T2DNon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 99% · 21,800 Btu/hMUD18KCH23S-ONon-ducted, up to 1.5 tonsbeats 93% · 36,000 Btu/hHVHM-36T2DDucted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
ACD vs HAXXAIR: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • ACD (median, middle 50%)
  • HAXXAIR (median, middle 50%)
Heating capacity, % of its 47°F maximum75%73%COP at maximum capacity1.822.05

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
ACD: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
ACD, 47°F24100%100%100%100%100%
ACD, 17°F2477%81%87%93%100%
ACD, 5°F2462%70%75%76%89%
ACD: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
ACD, 47°F242.552.713.093.323.42
ACD, 17°F241.912.042.12.32.39
ACD, 5°F241.81.811.821.861.92
HAXXAIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
HAXXAIR, 47°F19100%100%100%100%100%
HAXXAIR, 17°F1972%76%82%85%95%
HAXXAIR, 5°F1964%71%73%75%78%
HAXXAIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
HAXXAIR, 47°F192.22.472.72.812.94
HAXXAIR, 17°F191.9422.122.352.41
HAXXAIR, 5°F191.831.862.052.162.29

Source: NEEP ccASHP list · as of