Both views use the same certified data. This device remembers your choice.
ADP vs AIRDACH heat pumps
Measured against models of the same size and duct type, ADP scores higher on 4 of the 6 ratings. ADP has 24 outdoor models, AIRDACH has 23 outdoor models. ADP and AIRDACH have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ADP
- AIRDACH
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ADP | AIRDACH |
|---|---|---|
| Efficiency index | 56%median — | 58%median — |
| COP at 5°F | 45%median 1.88 | 48%median 1.91 |
| Capacity retention at 5°F | 75% (higher)median 81% | 40% (higher)median 67% |
| HSPF2 | 66% (higher)median 8.6 | 49% (higher)median 8.1 |
| SEER2 | 69% (higher)median 17.0 | 54% (higher)median 16.0 |
| EER2 | 33%median 10.0 | 58%median 11.7 |
| Heating capacity at 5°F | 69% (higher)median 31,000 Btu/h | 42% (higher)median 14,000 Btu/h |
| Outdoor models | 24 | 23 |
| AHRI certifications | 340 | 34 |
Share of models meeting each standard
| Standard | ADP | AIRDACH |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 54.2%13 models | 39.1%9 models |
| CEE 2026 Tier 1 (Split ASHP) | 54.2%13 models | 39.1%9 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 62.5%15 models | 21.7%5 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ADP
- AIRDACH
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ADP | AIRDACH |
|---|---|---|
| Ducted, 2 tons | 6 · index 53% | 2 · index — |
| Ducted, 2.5 to 3 tons | 9 · index 52% | 5 · index 66% |
| Ducted, 3.5 to 4.5 tons | 8 · index 63% | 6 · index 64% |
| Ducted, 5 tons and up | 1 · index 61% | None |
| Ducted, up to 1.5 tons | None | 2 · index 57% |
| Non-ducted, up to 1.5 tons | None | 6 · index 59% |
| Non-ducted, 2 tons | None | 1 · index 57% |
| Non-ducted, 2.5 to 3 tons | None | 4 · index 51% |
| Non-ducted, 3.5 to 4.5 tons | None | 1 · index 52% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ADPCold-climate score, best model | AIRDACHCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 47.2(50 is the typical model of its size class)AMSH1800VM1-D1 of 2 models qualify · AHRI 210474672 |
| Ducted, 2 tons | 67.8(50 is the typical model of its size class)SL25XPV-024-230A**with indoor coil LP36/37R9 and furnace EL297UH045XV36B5 of 5 models qualify · AHRI 213360207 | None on this board (0 of 2 models qualify) |
| Ducted, 2.5 to 3 tons | 75.3(50 is the typical model of its size class)AUWR-36U3SA2with ducted air handler F,PE*TT39379 of 10 models qualify · AHRI 215350408 | None on this board (0 of 5 models qualify) |
| Ducted, 3.5 to 4.5 tons | 78.2(50 is the typical model of its size class)BOVA-60HDN1-M20Gwith indoor coil HE35948 and furnace BGH96M100D5A6 of 8 models qualify · AHRI 212361477 | None on this board (0 of 6 models qualify) |
| Ducted, 5 tons and up | 74.9(50 is the typical model of its size class)AC060BXUPCHwith ducted air handler F,PE*CC79601 of 1 models qualify · AHRI 211289597 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 71.5(50 is the typical model of its size class)ACSH1823VM2-Dwith ductless indoor unit AIWH1800VM2-D3 of 6 models qualify · AHRI 209948207 |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 51.5(50 is the typical model of its size class)AMSH2700VM1-D1 of 4 models qualify · AHRI 210474674 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 39.6(50 is the typical model of its size class)AMSH4800VM1-D1 of 1 models qualify · AHRI 210474680 |
All-around best
| Size and duct type | ADPAll-around score, best model | AIRDACHAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 57.1(50 is the typical model of its size class)AMSH1800VM1-D1 of 2 models have all five ratings · AHRI 210474672 |
| Ducted, 2 tons | 83.8(50 is the typical model of its size class)SL25XPV-024-230A**with indoor coil LP36/37R9 and furnace EL297UH070XV36B7 of 7 models have all five ratings · AHRI 213360216 | None on this board (0 of 2 models have all five ratings) |
| Ducted, 2.5 to 3 tons | 77.6(50 is the typical model of its size class) (higher)SL25XPV-036-230A**with indoor coil L*35/36U9 and furnace EL297UH110XV48C8 of 8 models have all five ratings · AHRI 213360276 | 75.4(50 is the typical model of its size class)AMSH2700VM1-D2 of 5 models have all five ratings · AHRI 210474675 |
| Ducted, 3.5 to 4.5 tons | 82.8(50 is the typical model of its size class) (higher)SL25XPV-048-230A**with indoor coil LH42/62W9 and furnace EL297UH110XV60C8 of 8 models have all five ratings · AHRI 213361090 | 63.5(50 is the typical model of its size class)AMSH4800VM1-D1 of 6 models have all five ratings · AHRI 210474681 |
| Ducted, 5 tons and up | 61.1(50 is the typical model of its size class)AC060BXUPCHwith ducted air handler F,PE*CC79601 of 1 models have all five ratings · AHRI 211289597 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 76.4(50 is the typical model of its size class)ACSH1823VM2-Dwith ductless indoor unit AIWH1800VM2-D6 of 6 models have all five ratings · AHRI 209948207 |
| Non-ducted, 2 tons | No models in this size class | 57.2(50 is the typical model of its size class)ACSH2421VM2-Dwith ductless indoor unit AIWH2400VM2-D1 of 1 models have all five ratings · AHRI 209948204 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 68.0(50 is the typical model of its size class)AMSH2700VM1-D3 of 4 models have all five ratings · AHRI 210474674 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 51.7(50 is the typical model of its size class)AMSH4800VM1-D1 of 1 models have all five ratings · AHRI 210474680 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ADP | AIRDACH |
|---|---|---|
| COP at 5°F | beats 90% · 2.50BOVA-60HDN1-M20GDucted, 3.5 to 4.5 tons | beats 96% · 2.38ACSH1823VM2-DNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 91%AC060BXUPCHDucted, 5 tons and up | beats 68% · 80%ACSH0924VM2-DNon-ducted, up to 1.5 tons |
| HSPF2 | beats 96% · 9.0AC060BXUPCHDucted, 5 tons and up | beats 95% · 9.7AMSH4800VM1-DDucted, 3.5 to 4.5 tons |
| SEER2 | beats 100% · 23.0SL25XPV-024-230A**Ducted, 2 tons | beats 98% · 21.0AMSH2700VM1-DDucted, 2.5 to 3 tons |
| EER2 | beats 100% · 14.5SL25XPV-024-230A**Ducted, 2 tons | beats 85% · 14.0ACSH0924VM2-DNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 99% · 32,800 Btu/hWSEHV2436RA1-CAlso listed as WSEHV2436RA1-NDucted, 2 tons | beats 86% · 14,000 Btu/hAMSH1800VM1-DNon-ducted, up to 1.5 tons |