Skip to content

ADP vs AireForce heat pumps

Measured against models of the same size and duct type, ADP scores higher on 5 of the 6 ratings. ADP has 24 outdoor models, AireForce has 23 outdoor models. ADP and AireForce have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ADP and AireForce on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ADP scores higher on 5 of the 6 ratings.
  • ADP
  • AireForce
  • Other ranked manufacturers
ADPAireForce

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingADPAireForce
Efficiency index56% (higher)median —46% (higher)median —
COP at 5°F45% (higher)median 1.8833% (higher)median 1.81
Capacity retention at 5°F75% (higher)median 81%66% (higher)median 77%
HSPF266% (higher)median 8.637% (higher)median 8.5
SEER269% (higher)median 17.040% (higher)median 17.5
EER233%median 10.043%median 11.0
Heating capacity at 5°F69% (higher)median 31,000 Btu/h64% (higher)median 19,800 Btu/h
Outdoor models2423
AHRI certifications34054

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardADPAireForce
CEE 2025 Tier 1 (Split ASHP)54.2%13 models52.2%12 models
CEE 2026 Tier 1 (Split ASHP)54.2%13 models52.2%12 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)62.5%15 models56.5%13 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models34.8%8 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • ADP
  • AireForce
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeADPAireForce
Ducted, 2 tons6 · index 53%3 · index 53%
Ducted, 2.5 to 3 tons9 · index 52%4 · index 52%
Ducted, 3.5 to 4.5 tons8 · index 63%3 · index 63%
Ducted, 5 tons and up1 · index 61%None
Ducted, up to 1.5 tonsNone3 · index 32%
Non-ducted, up to 1.5 tonsNone8 · index 29%
Non-ducted, 2 tonsNone2 · index 58%
Non-ducted, 2.5 to 3 tonsNone5 · index 61%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeADPCold-climate score, best modelAireForceCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class36.3(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 3 models qualify · AHRI 211635197
Ducted, 2 tons67.8(50 is the typical model of its size class) (higher)SL25XPV-024-230A**with indoor coil LP36/37R9 and furnace EL297UH045XV36B5 of 5 models qualify · AHRI 21336020750.3(50 is the typical model of its size class)GXH24(7.0)FMK4DH-11 of 2 models qualify · AHRI 211635198
Ducted, 2.5 to 3 tons75.3(50 is the typical model of its size class) (higher)AUWR-36U3SA2with ducted air handler F,PE*TT39379 of 10 models qualify · AHRI 21535040855.4(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH**-36MSK4DH14 of 5 models qualify · AHRI 206724405
Ducted, 3.5 to 4.5 tons78.2(50 is the typical model of its size class) (higher)BOVA-60HDN1-M20Gwith indoor coil HE35948 and furnace BGH96M100D5A6 of 8 models qualify · AHRI 21236147758.3(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 3 models qualify · AHRI 206724406
Ducted, 5 tons and up74.9(50 is the typical model of its size class)AC060BXUPCHwith ducted air handler F,PE*CC79601 of 1 models qualify · AHRI 211289597No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class74.0(50 is the typical model of its size class)GXH18(5.3)FMK4DH-17 of 8 models qualify · AHRI 211635192
Non-ducted, 2 tonsNo models in this size class77.3(50 is the typical model of its size class)GXH24(7.0)FMK4DH-12 of 2 models qualify · AHRI 211635193
Non-ducted, 2.5 to 3 tonsNo models in this size class74.7(50 is the typical model of its size class)GXH42(12.3)FMK4DH-15 of 5 models qualify · AHRI 211635196

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeADPAll-around score, best modelAireForceAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class31.8(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 3 models have all five ratings · AHRI 211635197
Ducted, 2 tons83.8(50 is the typical model of its size class) (higher)SL25XPV-024-230A**with indoor coil LP36/37R9 and furnace EL297UH070XV36B7 of 7 models have all five ratings · AHRI 21336021660.8(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH24-**MSK4DH12 of 3 models have all five ratings · AHRI 206724404
Ducted, 2.5 to 3 tons77.6(50 is the typical model of its size class) (higher)SL25XPV-036-230A**with indoor coil L*35/36U9 and furnace EL297UH110XV48C8 of 8 models have all five ratings · AHRI 21336027653.0(50 is the typical model of its size class)GXH30(8.8)FMK4DH-13 of 4 models have all five ratings · AHRI 211635199
Ducted, 3.5 to 4.5 tons82.8(50 is the typical model of its size class) (higher)SL25XPV-048-230A**with indoor coil LH42/62W9 and furnace EL297UH110XV60C8 of 8 models have all five ratings · AHRI 21336109063.3(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 3 models have all five ratings · AHRI 206724406
Ducted, 5 tons and up61.1(50 is the typical model of its size class)AC060BXUPCHwith ducted air handler F,PE*CC79601 of 1 models have all five ratings · AHRI 211289597No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class58.6(50 is the typical model of its size class)GXH18(5.3)FMK4DH-18 of 8 models have all five ratings · AHRI 211635192
Non-ducted, 2 tonsNo models in this size class72.2(50 is the typical model of its size class)GXH24(7.0)FMK4DH-12 of 2 models have all five ratings · AHRI 211635193
Non-ducted, 2.5 to 3 tonsNo models in this size class70.9(50 is the typical model of its size class)GXH42(12.3)FMK4DH-15 of 5 models have all five ratings · AHRI 211635196

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingADPAireForce
COP at 5°Fbeats 90% · 2.50BOVA-60HDN1-M20GDucted, 3.5 to 4.5 tonsbeats 89% · 2.21GXH18(5.3)FMK4DH-1Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 91%AC060BXUPCHDucted, 5 tons and upbeats 86% · 89%GXH30(8.8)FMK4DH-1Ducted, 2.5 to 3 tons
HSPF2beats 96% · 9.0AC060BXUPCHDucted, 5 tons and upbeats 82% · 10.0GXH30(8.8)FMK4DH-1Non-ducted, 2.5 to 3 tons
SEER2beats 100% · 23.0SL25XPV-024-230A**Ducted, 2 tonsbeats 83% · 24.0GXH12(3.5)LSK4DH2Non-ducted, up to 1.5 tons
EER2beats 100% · 14.5SL25XPV-024-230A**Ducted, 2 tonsbeats 84% · 12.5GXH30(8.8)FMK4DH-1Non-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 99% · 32,800 Btu/hWSEHV2436RA1-CAlso listed as WSEHV2436RA1-NDucted, 2 tonsbeats 87% · 14,500 Btu/hGXH18(5.3)LSK4DH2Non-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter