Skip to content

ADP vs Ecoer: heat pump ratings compared

Against heat pumps of the same size and type, a typical ADP model beats 49% and a typical Ecoer model 54%. Ecoer rates higher overall.

Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated

ADP

49%

of similar heat pumps beaten by its typical model

About average

15 models listed

Ecoer

54%

of similar heat pumps beaten by its typical model

About average

15 models listed

Rating by ratingEach bar is the share of same-size, same-type heat pumps that a typical model beats, so the two brands compare fairly even if they make different sizes.
  • Efficiency on a 5°F dayCOP at 5°FADP: Beats 35%Ecoer: Beats 46%
  • Heating power kept at 5°FCapacity at 5°F vs 47°FADP: Beats 86%Ecoer: Beats 65%
  • Winter-long heating efficiencyHSPF2ADP: Beats 51%Ecoer: Beats 68%
  • Summer-long cooling efficiencySEER2ADP: Beats 37%Ecoer: Beats 60%
  • Hot-day cooling efficiencyEER2ADP: Beats 43%Ecoer: Beats 37%

Average (50%)Dashed outline: the other brand, for comparison

Want ranks, distributions per size class and cold-weather curves? Switch to Advanced

Rebate standards

Share of each brand’s models that meet the level. Programs can have other rules too.
  • CEE 2025

    ADP
    27%
    Ecoer
    93%
  • Xcel CC

    ADP
    87%
    Ecoer
    93%
  • CEE Advanced

    ADP
    7%
    Ecoer
    0%
  • ENERGY STAR CC

    ADP
    0%
    Ecoer
    100%

All-around best, ducted 3.5–4.5 tons

Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.

ADP

  1. 1KUSXA422Awith ducted air handler HG48*60+TXV+TDADP3.5 tons · 41,000 Btu/h · DuctedCold-climate pick, score 66.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    98% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.9 (HSPF2)
    Good
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Good
    65.1score / 100Heating 66 · Cooling 64
  2. 2KUSXA482Awith ducted air handler HG48*60+TXV+TDADP4 tons · 45,500 Btu/h · DuctedCold-climate pick, score 66.4Meets CEE 2025, CEE 2026, Xcel CC
    Heat kept at 5°F
    90% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.1 (HSPF2)
    Great
    Cooling efficiency
    16.0 (SEER2)
    Good
    Hot-day cooling
    11.7 (EER2)
    Good
    65.0score / 100Heating 66 · Cooling 64
  3. 3KUSXB601Awith ducted air handler PL60H210P29*+TXV+TDADP4 tons · 45,500 Btu/h · DuctedCold-climate pick, score 58.2Meets Xcel CC
    Heat kept at 5°F
    85% (Capacity at 5°F vs 47°F)
    Great
    Efficiency at 5°F
    1.80 (COP at 5°F)
    Below the middle
    Winter efficiency
    8.9 (HSPF2)
    Good
    Cooling efficiency
    15.2 (SEER2)
    Below the middle
    Hot-day cooling
    11.7 (EER2)
    Good
    56.3score / 100Heating 56 · Cooling 57

Ecoer

  1. 1ERDA19H-60AB*Ecoer4.5 tons · 56,000 Btu/h · DuctedCold-climate pick, score 56.7Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.5 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.2 (EER2)
    Good
    63.7score / 100Heating 57 · Cooling 71
  2. 2ERDA19H-60BB*Ecoer4.5 tons · 56,000 Btu/h · DuctedCold-climate pick, score 55.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Below the middle
    Efficiency at 5°F
    1.90 (COP at 5°F)
    Below the middle
    Winter efficiency
    9.3 (HSPF2)
    Great
    Cooling efficiency
    19.0 (SEER2)
    Great
    Hot-day cooling
    11.2 (EER2)
    Good
    63.1score / 100Heating 55 · Cooling 71
  3. 3EODA17H-4860AD*with ducted air handler EAHDEN-48BEEcoer4 tons · 46,000 Btu/h · DuctedCold-climate pick, score 62.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
    Heat kept at 5°F
    71% (Capacity at 5°F vs 47°F)
    Good
    Efficiency at 5°F
    2.00 (COP at 5°F)
    Good
    Winter efficiency
    8.8 (HSPF2)
    Good
    Cooling efficiency
    17.5 (SEER2)
    Good
    Hot-day cooling
    11.2 (EER2)
    Good
    60.7score / 100Heating 58 · Cooling 63

These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.

Next steps

The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.

Open the advanced view