Skip to content

ADP vs Ecoer heat pumps

Measured against models of the same size and duct type, ADP and Ecoer split the 6 ratings 3–3. ADP has 15 outdoor models, Ecoer has 15 outdoor models. ADP has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ADP and Ecoer on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ADP and Ecoer split the 6 ratings 3–3.
  • ADP
  • Ecoer
  • Other ranked manufacturers
ADPEcoer

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingADPEcoer
Efficiency index49%median —54%median — · 13th ranked
COP at 5°F35%median 1.8646%median 1.90 · 23rd ranked
Capacity retention at 5°F86% (higher)median 96%65% (higher)median 79% · 3rd ranked
HSPF251%median 8.568%median 9.0 · 3rd ranked
SEER237%median 15.260%median 17.5 · 8th ranked
EER243% (higher)median 11.037% (higher)median 11.0 · 27th ranked
Heating capacity at 5°F84% (higher)median 33,000 Btu/h69% (higher)median 33,600 Btu/h · 2nd ranked
Outdoor models1515
AHRI certifications259287

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardADPEcoer
CEE 2025 Tier 1 (Split ASHP)26.7%4 models93.3%14 models
CEE 2026 Tier 1 (Split ASHP)26.7%4 models93.3%14 models
CEE Advanced Tier (Split ASHP)6.7%1 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)86.7%13 models93.3%14 models
DOE Cold Climate Heat Pump Challenge6.7%1 models0%0 models
ENERGY STAR Cold Climate0%0 models100%15 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 3 groups where both have models
  • ADP
  • Ecoer
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeADPEcoer
Ducted, up to 1.5 tons3 · index 45%None
Ducted, 2 tons4 · index 44%4 · index 57%
Ducted, 2.5–3 tons3 · index 43%4 · index 53%
Ducted, 3.5–4.5 tons5 · index 58%7 · index 52%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeADPCold-climate score, best modelEcoerCold-climate score, best model
Ducted, up to 1.5 tons57.1(50 is the typical model of its size class)KUSXA181Awith ducted air handler V36H***P12*+TXV+TD2 of 2 models qualify · AHRI 217350899No models in this size class
Ducted, 2 tons68.4(50 is the typical model of its size class)KUSXB241Awith ducted air handler FE*G32*30+TXV5 of 5 models qualify · AHRI 21773011780.1(50 is the typical model of its size class) (higher)EODA19H-2436AB*with indoor coil D(A,C,E)24C3J+TDR and furnace FG7TC-060D-V24B3 of 3 models qualify · AHRI 217627911
Ducted, 2.5–3 tons54.9(50 is the typical model of its size class)KUSXB361Awith ducted air handler FC*G32*36+TXV+TD3 of 3 models qualify · AHRI 21773011178.1(50 is the typical model of its size class) (higher)EODA19H-4860AB*with indoor coil D(A,C,E)36C3J+TDR and furnace FG7TC-060D-V24B6 of 6 models qualify · AHRI 217627934
Ducted, 3.5–4.5 tons66.4(50 is the typical model of its size class)KUSXA482Awith ducted air handler HG48*60+TXV+TD5 of 5 models qualify · AHRI 21719871068.8(50 is the typical model of its size class) (higher)ESCA17H-48ABAwith ducted air handler EAHDEC-48ABA6 of 6 models qualify · AHRI 216706025

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeADPAll-around score, best modelEcoerAll-around score, best model
Ducted, up to 1.5 tons44.7(50 is the typical model of its size class)KUSXA181Awith ducted air handler V36H***P12*+TXV+TD2 of 2 models have all five ratings · AHRI 217350899No models in this size class
Ducted, 2 tons53.2(50 is the typical model of its size class)KUSXB241Awith ducted air handler FE*G32*30+TXV4 of 4 models have all five ratings · AHRI 21773011780.8(50 is the typical model of its size class) (higher)EODA19H-2436AB*with ducted air handler EAHDEN-24AB4 of 4 models have all five ratings · AHRI 216445239
Ducted, 2.5–3 tons53.4(50 is the typical model of its size class)KUSXA361Awith ducted air handler V36H175P15*+TXV+TD4 of 4 models have all five ratings · AHRI 21735090979.0(50 is the typical model of its size class) (higher)EODA19H-4860AB*with ducted air handler EAHDEN-36AB4 of 4 models have all five ratings · AHRI 216620321
Ducted, 3.5–4.5 tons65.1(50 is the typical model of its size class) (higher)KUSXA422Awith ducted air handler HG48*60+TXV+TD5 of 5 models have all five ratings · AHRI 21719870863.7(50 is the typical model of its size class)ERDA19H-60AB*7 of 7 models have all five ratings · AHRI 217463590

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingADPEcoer
COP at 5°Fbeats 77% · 2.12KUSXB241ADucted, up to 1.5 tonsbeats 96% · 2.65EODA19H-4860AB*Ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 100% · 128%KUSXA301ADucted, 2 tonsbeats 92% · 105%ESCA17H-36ABADucted, 2.5–3 tons
HSPF2beats 73% · 9.1KUSXA482ADucted, 3.5–4.5 tonsbeats 91% · 10.3ESCA17H-36ABADucted, 2.5–3 tons
SEER2beats 50% · 16.0KUSXA422ADucted, 3.5–4.5 tonsbeats 87% · 20.0EODA19H-2436AB*Ducted, 2 tons
EER2beats 67% · 11.7KUSXA422ADucted, 3.5–4.5 tonsbeats 90% · 12.5EODA19H-4860AB*Ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 100% · 24,000 Btu/hKUSXB241ADucted, up to 1.5 tonsbeats 97% · 39,000 Btu/hESCA17H-36ABADucted, 2.5–3 tons

More comparisons