Skip to content

Ecoer vs Gridless heat pumps

Measured against models of the same size and duct type, Gridless scores higher on 4 of the 6 ratings. Ecoer has 15 outdoor models, Gridless has 15 outdoor models. Gridless has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Ecoer and Gridless on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Gridless scores higher on 4 of the 6 ratings.
  • Ecoer
  • Gridless
  • Other ranked manufacturers
EcoerGridless

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingEcoerGridless
Efficiency index54%median — · 13th ranked70%median —
COP at 5°F46%median 1.90 · 23rd ranked64%median 2.09
Capacity retention at 5°F65%median 79% · 3rd ranked73%median 88%
HSPF268% (higher)median 9.0 · 3rd ranked62% (higher)median 9.5
SEER260%median 17.5 · 8th ranked73%median 22.0
EER237%median 11.0 · 27th ranked73%median 12.3
Heating capacity at 5°F69% (higher)median 33,600 Btu/h · 2nd ranked66% (higher)median 18,000 Btu/h
Outdoor models1515
AHRI certifications28728

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardEcoerGridless
CEE 2025 Tier 1 (Split ASHP)93.3%14 models100%15 models
CEE 2026 Tier 1 (Split ASHP)93.3%14 models100%15 models
CEE Advanced Tier (Split ASHP)0%0 models13.3%2 models
Xcel Energy Colorado cold-climate ASHP (2025)93.3%14 models100%15 models
DOE Cold Climate Heat Pump Challenge0%0 models13.3%2 models
ENERGY STAR Cold Climate100%15 models100%15 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 3 groups where both have models
  • Ecoer
  • Gridless
  • All models of the group
Ducted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsDucted, 5 tons and up2.00321 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeEcoerGridless
Ducted, 2 tons4 · index 57%1 · index 47%
Ducted, 2.5–3 tons4 · index 53%1 · index 65%
Ducted, 3.5–4.5 tons7 · index 52%1 · index 82%
Ducted, 5 tons and upNone1 · index 81%
Non-ducted, up to 1.5 tonsNone7 · index 77%
Non-ducted, 2 tonsNone1 · index 61%
Non-ducted, 2.5–3 tonsNone2 · index 63%
Non-ducted, 3.5–4.5 tonsNone1 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeEcoerCold-climate score, best modelGridlessCold-climate score, best model
Ducted, 2 tons80.1(50 is the typical model of its size class)EODA19H-2436AB*with indoor coil D(A,C,E)24C3J+TDR and furnace FG7TC-060D-V24B3 of 3 models qualify · AHRI 21762791182.1(50 is the typical model of its size class) (higher)GRID24OCwith ducted air handler GRID24VAH1 of 1 models qualify · AHRI 217115267
Ducted, 2.5–3 tons78.1(50 is the typical model of its size class)EODA19H-4860AB*with indoor coil D(A,C,E)36C3J+TDR and furnace FG7TC-060D-V24B6 of 6 models qualify · AHRI 21762793487.9(50 is the typical model of its size class) (higher)GRID36OCwith ducted air handler GRID36VAH1 of 1 models qualify · AHRI 217115268
Ducted, 3.5–4.5 tons68.8(50 is the typical model of its size class)ESCA17H-48ABAwith ducted air handler EAHDEC-48ABA6 of 6 models qualify · AHRI 21670602577.3(50 is the typical model of its size class) (higher)GRID48OCwith ducted air handler GRID48VAH1 of 1 models qualify · AHRI 217115269
Ducted, 5 tons and upNo models in this size class88.7(50 is the typical model of its size class)GRID60OCwith ducted air handler GRID60VAH1 of 1 models qualify · AHRI 217115270
Non-ducted, up to 1.5 tonsNo models in this size class89.7(50 is the typical model of its size class)GRID09OHHVwith ductless indoor unit GRID09WHHV7 of 7 models qualify · AHRI 217101973
Non-ducted, 2 tonsNo models in this size class54.1(50 is the typical model of its size class)GRID24OHVwith ductless indoor unit GRID24WHV1 of 1 models qualify · AHRI 217101978
Non-ducted, 2.5–3 tonsNo models in this size class53.7(50 is the typical model of its size class)GRID36OM42 of 2 models qualify · AHRI 217123264
Non-ducted, 3.5–4.5 tonsNo models in this size class16.4(50 is the typical model of its size class)GRID48OM51 of 1 models qualify · AHRI 217123265

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeEcoerAll-around score, best modelGridlessAll-around score, best model
Ducted, 2 tons80.8(50 is the typical model of its size class) (higher)EODA19H-2436AB*with ducted air handler EAHDEN-24AB4 of 4 models have all five ratings · AHRI 21644523979.5(50 is the typical model of its size class)GRID24OCwith ducted air handler GRID24VAH1 of 1 models have all five ratings · AHRI 217115267
Ducted, 2.5–3 tons79.0(50 is the typical model of its size class)EODA19H-4860AB*with ducted air handler EAHDEN-36AB4 of 4 models have all five ratings · AHRI 21662032182.3(50 is the typical model of its size class) (higher)GRID36OCwith ducted air handler GRID36VAH1 of 1 models have all five ratings · AHRI 217115268
Ducted, 3.5–4.5 tons63.7(50 is the typical model of its size class)ERDA19H-60AB*7 of 7 models have all five ratings · AHRI 21746359082.3(50 is the typical model of its size class) (higher)GRID48OCwith ducted air handler GRID48VAH1 of 1 models have all five ratings · AHRI 217115269
Ducted, 5 tons and upNo models in this size class81.1(50 is the typical model of its size class)GRID60OCwith ducted air handler GRID60VAH1 of 1 models have all five ratings · AHRI 217115270
Non-ducted, up to 1.5 tonsNo models in this size class94.5(50 is the typical model of its size class)GRID09OHHVwith ductless indoor unit GRID09WHHV7 of 7 models have all five ratings · AHRI 217101973
Non-ducted, 2 tonsNo models in this size class61.3(50 is the typical model of its size class)GRID24OHVwith ductless indoor unit GRID24WHV1 of 1 models have all five ratings · AHRI 217101978
Non-ducted, 2.5–3 tonsNo models in this size class64.2(50 is the typical model of its size class)GRID24OM32 of 2 models have all five ratings · AHRI 217123263
Non-ducted, 3.5–4.5 tonsNo models in this size class43.7(50 is the typical model of its size class)GRID48OM51 of 1 models have all five ratings · AHRI 217123265

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingEcoerGridless
COP at 5°Fbeats 96% · 2.65EODA19H-4860AB*Ducted, 2.5–3 tonsbeats 98% · 2.42GRID60OCDucted, 5 tons and up
Capacity retention at 5°Fbeats 92% · 105%ESCA17H-36ABADucted, 2.5–3 tonsbeats 94% · 75%GRID60OCDucted, 5 tons and up
HSPF2beats 91% · 10.3ESCA17H-36ABADucted, 2.5–3 tonsbeats 96% · 10.5GRID36OCDucted, 2.5–3 tons
SEER2beats 87% · 20.0EODA19H-2436AB*Ducted, 2 tonsbeats 99% · 32.0GRID09OHHVNon-ducted, up to 1.5 tons
EER2beats 90% · 12.5EODA19H-4860AB*Ducted, 2.5–3 tonsbeats 100% · 18.4GRID09OHHVNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 97% · 39,000 Btu/hESCA17H-36ABADucted, 2.5–3 tonsbeats 93% · 18,000 Btu/hGRID18OHVNon-ducted, up to 1.5 tons

More comparisons