Skip to content

Ecoer vs EMI heat pumps

Measured against models of the same size and duct type, EMI scores higher on 4 of the 6 ratings. Ecoer has 15 outdoor models, EMI has 15 outdoor models. EMI has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Ecoer and EMI on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, EMI scores higher on 4 of the 6 ratings.
  • Ecoer
  • EMI
  • Other ranked manufacturers
EcoerEMI

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingEcoerEMI
Efficiency index54%median — · 13th ranked62%median —
COP at 5°F46%median 1.90 · 23rd ranked56%median 2.00
Capacity retention at 5°F65% (higher)median 79% · 3rd ranked63% (higher)median 95%
HSPF268%median 9.0 · 3rd ranked69%median 10.5
SEER260%median 17.5 · 8th ranked61%median 21.4
EER237%median 11.0 · 27th ranked60%median 12.5
Heating capacity at 5°F69% (higher)median 33,600 Btu/h · 2nd ranked60% (higher)median 18,000 Btu/h
Outdoor models1515
AHRI certifications28727

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardEcoerEMI
CEE 2025 Tier 1 (Split ASHP)93.3%14 models86.7%13 models
CEE 2026 Tier 1 (Split ASHP)93.3%14 models86.7%13 models
CEE Advanced Tier (Split ASHP)0%0 models6.7%1 models
Xcel Energy Colorado cold-climate ASHP (2025)93.3%14 models73.3%11 models
DOE Cold Climate Heat Pump Challenge0%0 models6.7%1 models
ENERGY STAR Cold Climate100%15 models73.3%11 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • Ecoer
  • EMI
  • All models of the group
Ducted, up to 1.5 tons1.901,783 modelsDucted, 2 tons2.001,090 modelsDucted, 2.5–3 tons2.001,909 modelsDucted, 3.5–4.5 tons2.002,224 modelsNon-ducted, up to 1.5 tons1.953,455 modelsNon-ducted, 2 tons2.00863 modelsNon-ducted, 2.5–3 tons2.001,106 modelsNon-ducted, 3.5–4.5 tons2.00564 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeEcoerEMI
Ducted, 2 tons4 · index 57%None
Ducted, 2.5–3 tons4 · index 53%2 · index 81%
Ducted, 3.5–4.5 tons7 · index 52%1 · index 84%
Ducted, up to 1.5 tonsNone1 · index 77%
Non-ducted, up to 1.5 tonsNone8 · index 60%
Non-ducted, 2 tonsNone2 · index 53%
Non-ducted, 2.5–3 tonsNone4 · index 46%
Non-ducted, 3.5–4.5 tonsNone1 · index 76%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeEcoerCold-climate score, best modelEMICold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class70.8(50 is the typical model of its size class)EMXMZ218DA1 of 1 models qualify · AHRI 215444941
Ducted, 2 tons80.1(50 is the typical model of its size class)EODA19H-2436AB*with indoor coil D(A,C,E)24C3J+TDR and furnace FG7TC-060D-V24B3 of 3 models qualify · AHRI 217627911No models in this size class
Ducted, 2.5–3 tons78.1(50 is the typical model of its size class)EODA19H-4860AB*with indoor coil D(A,C,E)36C3J+TDR and furnace FG7TC-060D-V24B6 of 6 models qualify · AHRI 21762793482.5(50 is the typical model of its size class) (higher)EMXMZ436DA2 of 2 models qualify · AHRI 215444947
Ducted, 3.5–4.5 tons68.8(50 is the typical model of its size class)ESCA17H-48ABAwith ducted air handler EAHDEC-48ABA6 of 6 models qualify · AHRI 21670602582.7(50 is the typical model of its size class) (higher)EMXMZ548DA1 of 1 models qualify · AHRI 215444950
Non-ducted, up to 1.5 tonsNo models in this size class96.7(50 is the typical model of its size class)EMXSZ106DAwith ductless indoor unit EMXWAL06DA6 of 8 models qualify · AHRI 215444935
Non-ducted, 2 tonsNo models in this size class88.4(50 is the typical model of its size class)EMXSZ124DAwith ductless indoor unit EMXWAL24DA2 of 2 models qualify · AHRI 215444939
Non-ducted, 2.5–3 tonsNo models in this size class78.0(50 is the typical model of its size class)EMXMZ436DA2 of 4 models qualify · AHRI 215444948
Non-ducted, 3.5–4.5 tonsNo models in this size class73.4(50 is the typical model of its size class)EMXMZ548DA1 of 1 models qualify · AHRI 215444951

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeEcoerAll-around score, best modelEMIAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class77.4(50 is the typical model of its size class)EMXMZ218DA1 of 1 models have all five ratings · AHRI 215444941
Ducted, 2 tons80.8(50 is the typical model of its size class)EODA19H-2436AB*with ducted air handler EAHDEN-24AB4 of 4 models have all five ratings · AHRI 216445239No models in this size class
Ducted, 2.5–3 tons79.0(50 is the typical model of its size class)EODA19H-4860AB*with ducted air handler EAHDEN-36AB4 of 4 models have all five ratings · AHRI 21662032183.6(50 is the typical model of its size class) (higher)EMXMZ436DA2 of 2 models have all five ratings · AHRI 215444947
Ducted, 3.5–4.5 tons63.7(50 is the typical model of its size class)ERDA19H-60AB*7 of 7 models have all five ratings · AHRI 21746359083.9(50 is the typical model of its size class) (higher)EMXMZ548DA1 of 1 models have all five ratings · AHRI 215444950
Non-ducted, up to 1.5 tonsNo models in this size class96.2(50 is the typical model of its size class)EMXSZ106DAwith ductless indoor unit EMXWAL06DA8 of 8 models have all five ratings · AHRI 215444935
Non-ducted, 2 tonsNo models in this size class76.4(50 is the typical model of its size class)EMXSZ124DAwith ductless indoor unit EMXWAL24DA2 of 2 models have all five ratings · AHRI 215444939
Non-ducted, 2.5–3 tonsNo models in this size class78.3(50 is the typical model of its size class)EMXMZ436DA4 of 4 models have all five ratings · AHRI 215444946
Non-ducted, 3.5–4.5 tonsNo models in this size class75.6(50 is the typical model of its size class)EMXMZ548DA1 of 1 models have all five ratings · AHRI 215444949

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingEcoerEMI
COP at 5°Fbeats 96% · 2.65EODA19H-4860AB*Ducted, 2.5–3 tonsbeats 97% · 2.40EMXSZ106DANon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 92% · 105%ESCA17H-36ABADucted, 2.5–3 tonsbeats 94% · 110%EMXSZ106DANon-ducted, up to 1.5 tons
HSPF2beats 91% · 10.3ESCA17H-36ABADucted, 2.5–3 tonsbeats 99% · 14.8EMXSZ106DANon-ducted, up to 1.5 tons
SEER2beats 87% · 20.0EODA19H-2436AB*Ducted, 2 tonsbeats 96% · 20.4EMXMZ548DADucted, 3.5–4.5 tons
EER2beats 90% · 12.5EODA19H-4860AB*Ducted, 2.5–3 tonsbeats 99% · 18.0EMXSZ106DANon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 97% · 39,000 Btu/hESCA17H-36ABADucted, 2.5–3 tonsbeats 97% · 19,000 Btu/hEMXMZ218DANon-ducted, up to 1.5 tons

More comparisons