Both views use the same certified data. This device remembers your choice.
Ecoer vs EMI heat pumps
Measured against models of the same size and duct type, EMI scores higher on 4 of the 6 ratings. Ecoer has 15 outdoor models, EMI has 15 outdoor models. EMI has no QMID on file and is not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Ecoer
- EMI
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Ecoer | EMI |
|---|---|---|
| Efficiency index | 54%median — · 12th ranked | 63%median — |
| COP at 5°F | 46%median 1.90 · 24th ranked | 56%median 2.00 |
| Capacity retention at 5°F | 65% (higher)median 79% · 3rd ranked | 64% (higher)median 95% |
| HSPF2 | 67%median 9.0 · 3rd ranked | 70%median 10.5 |
| SEER2 | 60%median 17.5 · 7th ranked | 62%median 21.4 |
| EER2 | 38%median 11.0 · 28th ranked | 61%median 12.5 |
| Heating capacity at 5°F | 69% (higher)median 33,600 Btu/h · 2nd ranked | 61% (higher)median 18,000 Btu/h |
| Outdoor models | 15 | 15 |
| AHRI certifications | 288 | 27 |
Share of models meeting each standard
| Standard | Ecoer | EMI |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 93.3%14 models | 86.7%13 models |
| CEE 2026 Tier 1 (Split ASHP) | 93.3%14 models | 86.7%13 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 6.7%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 93.3%14 models | 73.3%11 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 6.7%1 models |
| ENERGY STAR Cold Climate | 100%15 models | 73.3%11 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Ecoer
- EMI
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Ecoer | EMI |
|---|---|---|
| Ducted, 2 tons | 4 · index 57% | None |
| Ducted, 2.5 to 3 tons | 4 · index 53% | 2 · index 81% |
| Ducted, 3.5 to 4.5 tons | 7 · index 53% | 1 · index 84% |
| Ducted, up to 1.5 tons | None | 1 · index 78% |
| Non-ducted, up to 1.5 tons | None | 8 · index 62% |
| Non-ducted, 2 tons | None | 2 · index 55% |
| Non-ducted, 2.5 to 3 tons | None | 4 · index 47% |
| Non-ducted, 3.5 to 4.5 tons | None | 1 · index 75% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | EcoerCold-climate score, best model | EMICold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 71.3(50 is the typical model of its size class)EMXMZ218DA1 of 1 models qualify · AHRI 215444941 |
| Ducted, 2 tons | 79.9(50 is the typical model of its size class)EODA19H-2436AB*with indoor coil D(A,C,E)24C3J+TDR and furnace FG7TC-060D-V24B3 of 3 models qualify · AHRI 217627911 | No models in this size class |
| Ducted, 2.5 to 3 tons | 73.4(50 is the typical model of its size class)ESCA17H-36ABAwith ducted air handler EAHDEC-36ABA5 of 5 models qualify · AHRI 216707852 | 82.7(50 is the typical model of its size class) (higher)EMXMZ436DA2 of 2 models qualify · AHRI 215444947 |
| Ducted, 3.5 to 4.5 tons | 78.2(50 is the typical model of its size class)EODA19H-4860AB*with indoor coil D(A,C,E)48C3J+TDR and furnace FG7TC-080D-V35C7 of 7 models qualify · AHRI 217627963 | 82.6(50 is the typical model of its size class) (higher)EMXMZ548DA1 of 1 models qualify · AHRI 215444950 |
| Non-ducted, up to 1.5 tons | No models in this size class | 97.0(50 is the typical model of its size class)EMXSZ106DAwith ductless indoor unit EMXWAL06DA6 of 8 models qualify · AHRI 215444935 |
| Non-ducted, 2 tons | No models in this size class | 89.6(50 is the typical model of its size class)EMXSZ124DAwith ductless indoor unit EMXWAL24DA2 of 2 models qualify · AHRI 215444939 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 78.3(50 is the typical model of its size class)EMXMZ436DA2 of 4 models qualify · AHRI 215444948 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 73.6(50 is the typical model of its size class)EMXMZ548DA1 of 1 models qualify · AHRI 215444951 |
All-around best
| Size and duct type | EcoerAll-around score, best model | EMIAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 77.9(50 is the typical model of its size class)EMXMZ218DA1 of 1 models have all five ratings · AHRI 215444941 |
| Ducted, 2 tons | 80.7(50 is the typical model of its size class)EODA19H-2436AB*with ducted air handler EAHDEN-24AB4 of 4 models have all five ratings · AHRI 216445239 | No models in this size class |
| Ducted, 2.5 to 3 tons | 79.1(50 is the typical model of its size class)EODA19H-4860AB*with ducted air handler EAHDEN-36AB4 of 4 models have all five ratings · AHRI 216620321 | 83.9(50 is the typical model of its size class) (higher)EMXMZ436DA2 of 2 models have all five ratings · AHRI 215444947 |
| Ducted, 3.5 to 4.5 tons | 64.4(50 is the typical model of its size class)ERDA19H-60AB*7 of 7 models have all five ratings · AHRI 217463590 | 84.3(50 is the typical model of its size class) (higher)EMXMZ548DA1 of 1 models have all five ratings · AHRI 215444950 |
| Non-ducted, up to 1.5 tons | No models in this size class | 96.6(50 is the typical model of its size class)EMXSZ106DAwith ductless indoor unit EMXWAL06DA8 of 8 models have all five ratings · AHRI 215444935 |
| Non-ducted, 2 tons | No models in this size class | 78.3(50 is the typical model of its size class)EMXSZ124DAwith ductless indoor unit EMXWAL24DA2 of 2 models have all five ratings · AHRI 215444939 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 78.8(50 is the typical model of its size class)EMXMZ436DA4 of 4 models have all five ratings · AHRI 215444946 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 75.4(50 is the typical model of its size class)EMXMZ548DA1 of 1 models have all five ratings · AHRI 215444949 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Ecoer | EMI |
|---|---|---|
| COP at 5°F | beats 97% · 2.65EODA19H-4860AB*Ducted, 2.5 to 3 tons | beats 97% · 2.40EMXSZ106DANon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 92% · 105%ESCA17H-36ABADucted, 2.5 to 3 tons | beats 95% · 110%EMXSZ106DANon-ducted, up to 1.5 tons |
| HSPF2 | beats 90% · 10.3ESCA17H-36ABADucted, 2.5 to 3 tons | beats 99% · 14.8EMXSZ106DANon-ducted, up to 1.5 tons |
| SEER2 | beats 86% · 20.0EODA19H-2436AB*Ducted, 2 tons | beats 96% · 27.4EMXSZ109DANon-ducted, up to 1.5 tons |
| EER2 | beats 90% · 12.5EODA19H-4860AB*Ducted, 2.5 to 3 tons | beats 99% · 18.0EMXSZ106DANon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 98% · 39,000 Btu/hESCA17H-36ABADucted, 2.5 to 3 tons | beats 97% · 19,000 Btu/hEMXMZ218DANon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- Ecoer (median, middle 50%)
- EMI (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 6,343 | 64% | 69% | 74% | 83% | 91% |
| All rated models, 5°F | 6,343 | 57% | 61% | 69% | 77% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 6,343 | 2.8 | 3 | 3.24 | 3.48 | 3.66 |
| All rated models, 17°F | 6,343 | 2 | 2.13 | 2.29 | 2.42 | 2.61 |
| All rated models, 5°F | 6,343 | 1.8 | 1.87 | 2 | 2.1 | 2.24 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ecoer, 47°F | 15 | 100% | 100% | 100% | 100% | 100% |
| Ecoer, 17°F | 15 | 70% | 72% | 78% | 82% | 85% |
| Ecoer, 5°F | 15 | 65% | 67% | 68% | 74% | 79% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Ecoer, 47°F | 15 | 3.02 | 3.16 | 3.2 | 3.28 | 3.34 |
| Ecoer, 17°F | 15 | 2.05 | 2.14 | 2.21 | 2.24 | 2.3 |
| Ecoer, 5°F | 15 | 1.82 | 1.87 | 1.9 | 2 | 2.06 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| EMI, 47°F | 15 | 100% | 100% | 100% | 100% | 100% |
| EMI, 17°F | 15 | 67% | 72% | 78% | 80% | 85% |
| EMI, 5°F | 15 | 59% | 63% | 70% | 78% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| EMI, 47°F | 15 | 2.79 | 2.92 | 3.1 | 3.35 | 3.42 |
| EMI, 17°F | 15 | 1.85 | 2.06 | 2.24 | 2.42 | 2.57 |
| EMI, 5°F | 15 | 1.8 | 1.84 | 1.99 | 2 | 2.25 |
Source: NEEP ccASHP list · as of