Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
ADP vs EMI: heat pump ratings compared
Against heat pumps of the same size and type, a typical ADP model beats 49% and a typical EMI model 62%. EMI rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
ADP
49%
of similar heat pumps beaten by its typical model
About average15 models listed
EMI
62%
of similar heat pumps beaten by its typical model
Well above average15 models listed
- Efficiency on a 5°F dayCOP at 5°FADP: Beats 35%EMI: Beats 56%
- Heating power kept at 5°FCapacity at 5°F vs 47°FADP: Beats 86%EMI: Beats 63%
- Winter-long heating efficiencyHSPF2ADP: Beats 51%EMI: Beats 69%
- Summer-long cooling efficiencySEER2ADP: Beats 37%EMI: Beats 61%
- Hot-day cooling efficiencyEER2ADP: Beats 43%EMI: Beats 60%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- ADP
- 27%
- EMI
- 87%
Xcel CC
- ADP
- 87%
- EMI
- 73%
CEE Advanced
- ADP
- 7%
- EMI
- 7%
ENERGY STAR CC
- ADP
- 0%
- EMI
- 73%
Top cold-climate picks, ducted 2 tons
Only units that keep at least 70% of their heat at 5°F, ranked on heat kept, efficiency at 5°F and seasonal efficiency (HSPF2), against units their size.
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
ADP
- 1KUSXB241Awith ducted air handler FE*G32*30+TXVADP2 tons · 21,600 Btu/h · DuctedKeeps 100% of its heat at 5°FMeets CEE Advanced, Xcel CC, DOE CCHP
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.12 (COP at 5°F)
- Good
- Seasonal efficiency
- 8.5 (HSPF2)
- Below the middle
- 2KUSXB301Awith ducted air handler HG8J*36+TXV+TDADP2 tons · 26,800 Btu/h · DuctedKeeps 101% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 101% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Good
- Seasonal efficiency
- 8.3 (HSPF2)
- Below the middle
- 3KUSXA301Awith ducted air handler HG36*36+TXV+TDADP2 tons · 23,000 Btu/h · DuctedKeeps 113% of its heat at 5°FMeets Xcel CC
- Heat kept at 5°F
- 113% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 1.86 (COP at 5°F)
- Below the middle
- Seasonal efficiency
- 8.8 (HSPF2)
- Good
EMI
No ducted, 2 tons model from EMI.
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view