AI AIR CONDITIONING vs DIRECT AIR heat pumps
Measured against models of the same size and duct type, AI AIR CONDITIONING scores higher on 4 of the 6 ratings. AI AIR CONDITIONING has 48 outdoor models, DIRECT AIR has 68 outdoor models. AI AIR CONDITIONING and DIRECT AIR have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AI AIR CONDITIONING
- DIRECT AIR
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AI AIR CONDITIONING | DIRECT AIR |
|---|---|---|
| Efficiency index | 61% (higher)median — | 58% (higher)median — |
| COP at 5°F | 50%median 1.90 | 50%median 1.91 |
| Capacity retention at 5°F | 58%median 72% | 59%median 79% |
| HSPF2 | 70% (higher)median 9.6 | 60% (higher)median 9.2 |
| SEER2 | 68% (higher)median 21.0 | 56% (higher)median 19.0 |
| EER2 | 56% (higher)median 12.0 | 53% (higher)median 11.7 |
| Heating capacity at 5°F | 57% (higher)median 19,471 Btu/h | 55% (higher)median 16,800 Btu/h |
| Outdoor models | 48 | 68 |
| AHRI certifications | 70 | 162 |
Share of models meeting each standard
| Standard | AI AIR CONDITIONING | DIRECT AIR |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 79.2%38 models | 61.8%42 models |
| CEE 2026 Tier 1 (Split ASHP) | 72.9%35 models | 60.3%41 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 1.5%1 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 56.3%27 models | 54.4%37 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 1.5%1 models |
| ENERGY STAR Cold Climate | 56.3%27 models | 50%34 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AI AIR CONDITIONING
- DIRECT AIR
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AI AIR CONDITIONING | DIRECT AIR |
|---|---|---|
| Ducted, up to 1.5 tons | 4 · index 54% | 12 · index 61% |
| Ducted, 2 tons | 2 · index 59% | 5 · index 67% |
| Ducted, 2.5 to 3 tons | 8 · index 62% | 13 · index 55% |
| Ducted, 3.5 to 4.5 tons | 7 · index 60% | 11 · index 58% |
| Ducted, 5 tons and up | 1 · index 42% | 2 · index 48% |
| Non-ducted, up to 1.5 tons | 20 · index 65% | 27 · index 56% |
| Non-ducted, 2 tons | 4 · index 63% | 6 · index 58% |
| Non-ducted, 2.5 to 3 tons | 8 · index 59% | 9 · index 60% |
| Non-ducted, 3.5 to 4.5 tons | 4 · index 51% | 4 · index 58% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AI AIR CONDITIONINGCold-climate score, best model | DIRECT AIRCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 60.9(50 is the typical model of its size class)AUO18-18N1-M3Hwith ducted air handler AUH2-18N1-BM3E3 of 4 models qualify · AHRI 213769922 | 75.2(50 is the typical model of its size class) (higher)DIRM-09HXPRO28-1Zwith ducted air handler DIRM-09HP-DUH9 of 12 models qualify · AHRI 207743749 |
| Ducted, 2 tons | 66.9(50 is the typical model of its size class)AUO18-24N1-M3Hwith ducted air handler AUH2-24N1-BM3E2 of 2 models qualify · AHRI 213769923 | 80.6(50 is the typical model of its size class) (higher)DIRM-24DA25-1Zwith ducted air handler DIRM-24HP-DU4 of 5 models qualify · AHRI 207743759 |
| Ducted, 2.5 to 3 tons | 80.4(50 is the typical model of its size class) (higher)A3MO22-27N1-M1H5 of 8 models qualify · AHRI 213769956 | 79.8(50 is the typical model of its size class)DIRM-36MAGICPRO20-OUwith ducted air handler HG8J936+TD5 of 13 models qualify · AHRI 212897484 |
| Ducted, 3.5 to 4.5 tons | 75.1(50 is the typical model of its size class)A5MO22-48N1-M1H4 of 7 models qualify · AHRI 213769962 | 75.1(50 is the typical model of its size class)DIRM-48HXPRO28-5Z3 of 11 models qualify · AHRI 207743795 |
| Ducted, 5 tons and up | None on this board (0 of 1 models qualify) | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 86.6(50 is the typical model of its size class)AO24-09N1-M1Hwith ductless indoor unit AW25-09N1-M112 of 20 models qualify · AHRI 213769938 | 89.8(50 is the typical model of its size class) (higher)DIRM-06HXPRO28-1Zwith ductless indoor unit DIRM-06HP-WM20 of 27 models qualify · AHRI 207743723 |
| Non-ducted, 2 tons | 85.5(50 is the typical model of its size class)AO29-24N1-M1Hwith ductless indoor unit AW29-24N1-M13 of 4 models qualify · AHRI 213769950 | 87.1(50 is the typical model of its size class) (higher)DIRM-24HXPRO28-1Zwith ductless indoor unit DIRM-24HP-CA5 of 6 models qualify · AHRI 207743744 |
| Non-ducted, 2.5 to 3 tons | 87.5(50 is the typical model of its size class) (higher)A4MO22-36N1-M1H4 of 8 models qualify · AHRI 213769958 | 80.2(50 is the typical model of its size class)DIRM-36HXPRO28-4Z2 of 9 models qualify · AHRI 207743791 |
| Non-ducted, 3.5 to 4.5 tons | 80.7(50 is the typical model of its size class) (higher)A5MO22-48N1-M1H2 of 4 models qualify · AHRI 213769961 | 76.5(50 is the typical model of its size class)DIRM-48HXPRO28-5Z2 of 4 models qualify · AHRI 207743794 |
All-around best
| Size and duct type | AI AIR CONDITIONINGAll-around score, best model | DIRECT AIRAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 63.8(50 is the typical model of its size class)AUO18-18N1-M3Hwith ducted air handler AUH2-18N1-BM3E4 of 4 models have all five ratings · AHRI 213769922 | 85.4(50 is the typical model of its size class) (higher)DIRM-09HXPRO28-1Zwith ducted air handler DIRM-09HP-DUH11 of 12 models have all five ratings · AHRI 207743749 |
| Ducted, 2 tons | 66.0(50 is the typical model of its size class)AUO18-24N1-M3Hwith ducted air handler AUH2-24N1-BM3E2 of 2 models have all five ratings · AHRI 213769923 | 84.0(50 is the typical model of its size class) (higher)DIRM-24DA25-1Zwith ducted air handler DIRM-24HP-DU4 of 5 models have all five ratings · AHRI 207743759 |
| Ducted, 2.5 to 3 tons | 83.7(50 is the typical model of its size class) (higher)A4MO22-36N1-M1H8 of 8 models have all five ratings · AHRI 213769959 | 75.4(50 is the typical model of its size class)DIRM-27DA25-3Z10 of 13 models have all five ratings · AHRI 207743777 |
| Ducted, 3.5 to 4.5 tons | 82.1(50 is the typical model of its size class)A5MO22-48N1-M1H7 of 7 models have all five ratings · AHRI 213769962 | 82.1(50 is the typical model of its size class)DIRM-48HXPRO28-5Z6 of 11 models have all five ratings · AHRI 207743795 |
| Ducted, 5 tons and up | 41.9(50 is the typical model of its size class)AUO17-60N1-M3with ducted air handler AUH2-60N1-DM3E1 of 1 models have all five ratings · AHRI 214296082 | 54.3(50 is the typical model of its size class) (higher)MOE30U-60HFN1-Mwith ducted air handler MHG-60HWFN1-MW2 of 2 models have all five ratings · AHRI 203269797 |
| Non-ducted, up to 1.5 tons | 89.3(50 is the typical model of its size class)AO29-09N1-M1Hwith ductless indoor unit AW29-09N1-M120 of 20 models have all five ratings · AHRI 213769947 | 92.3(50 is the typical model of its size class) (higher)DIRM-06HXPRO28-1Zwith ductless indoor unit DIRM-06HP-WM27 of 27 models have all five ratings · AHRI 207743723 |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class)AO29-24N1-M1Hwith ductless indoor unit AW29-24N1-M14 of 4 models have all five ratings · AHRI 213769950 | 84.9(50 is the typical model of its size class)DIRM-24HXPRO28-1Zwith ductless indoor unit DIRM-24HP-WM6 of 6 models have all five ratings · AHRI 207743727 |
| Non-ducted, 2.5 to 3 tons | 77.3(50 is the typical model of its size class)A4MO22-36N1-M1H8 of 8 models have all five ratings · AHRI 213769958 | 83.4(50 is the typical model of its size class) (higher)DIRM-36HXPRO28-4Z7 of 9 models have all five ratings · AHRI 207743791 |
| Non-ducted, 3.5 to 4.5 tons | 73.9(50 is the typical model of its size class)A5MO22-48N1-M1H4 of 4 models have all five ratings · AHRI 213769961 | 78.0(50 is the typical model of its size class) (higher)DIRM-48HXPRO28-5Z3 of 4 models have all five ratings · AHRI 207743794 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AI AIR CONDITIONING | DIRECT AIR |
|---|---|---|
| COP at 5°F | beats 97% · 2.22AO24-24N1-M1HNon-ducted, 2 tons | beats 97% · 2.39DIRM-12DA25-1ZNon-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 97% · 101%A3MO22-27N1-M1HDucted, 2.5 to 3 tons | beats 93% · 107%DIRM-06HXPRO28-1ZNon-ducted, up to 1.5 tons |
| HSPF2 | beats 100% · 14.5AO29-12N1-M1HNon-ducted, up to 1.5 tons | beats 99% · 13.6DIRM-06HXPRO28-1ZNon-ducted, up to 1.5 tons |
| SEER2 | beats 99% · 20.9A5MO22-48N1-M1HDucted, 3.5 to 4.5 tons | beats 99% · 20.9DIRM-48HXPRO28-5ZDucted, 3.5 to 4.5 tons |
| EER2 | beats 99% · 16.5AO29-09N1-M1HNon-ducted, up to 1.5 tons | beats 98% · 16.2DIRM-09HXPRO28-1ZNon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 96% · 20,000 Btu/hA2MO22-18N1-M1HNon-ducted, up to 1.5 tons | beats 96% · 20,000 Btu/hDIRM-18HXPRO28-2ZNon-ducted, up to 1.5 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- AI AIR CONDITIONING (median, middle 50%)
- DIRECT AIR (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,707 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,707 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,707 | 55% | 58% | 67% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,707 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,707 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,707 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AI AIR CONDITIONING, 47°F | 47 | 100% | 100% | 100% | 100% | 100% |
| AI AIR CONDITIONING, 17°F | 47 | 66% | 69% | 75% | 81% | 87% |
| AI AIR CONDITIONING, 5°F | 47 | 55% | 58% | 65% | 76% | 82% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| AI AIR CONDITIONING, 47°F | 47 | 2.68 | 2.88 | 3.04 | 3.17 | 3.41 |
| AI AIR CONDITIONING, 17°F | 47 | 1.98 | 2.03 | 2.18 | 2.38 | 2.48 |
| AI AIR CONDITIONING, 5°F | 47 | 1.8 | 1.83 | 1.9 | 2.07 | 2.18 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| DIRECT AIR, 47°F | 43 | 100% | 100% | 100% | 100% | 100% |
| DIRECT AIR, 17°F | 43 | 67% | 70% | 74% | 80% | 85% |
| DIRECT AIR, 5°F | 43 | 57% | 62% | 69% | 78% | 81% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| DIRECT AIR, 47°F | 43 | 2.76 | 2.87 | 3.04 | 3.25 | 3.52 |
| DIRECT AIR, 17°F | 43 | 1.95 | 2.04 | 2.13 | 2.28 | 2.41 |
| DIRECT AIR, 5°F | 43 | 1.83 | 1.87 | 1.98 | 2.08 | 2.2 |
Source: NEEP ccASHP list · as of