Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIR-CON vs DUOHOME: heat pump ratings compared
Against heat pumps of the same size and type, a typical AIR-CON model beats 45% and a typical DUOHOME model 57%. DUOHOME rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
AIR-CON
45%
of similar heat pumps beaten by its typical model
About average41 models listed
DUOHOME
57%
of similar heat pumps beaten by its typical model
Above average39 models listed
- Efficiency on a 5°F dayCOP at 5°FAIR-CON: Beats 57%DUOHOME: Beats 61%
- Heating power kept at 5°FCapacity at 5°F vs 47°FAIR-CON: Beats 33%DUOHOME: Beats 48%
- Winter-long heating efficiencyHSPF2AIR-CON: Beats 45%DUOHOME: Beats 66%
- Summer-long cooling efficiencySEER2AIR-CON: Beats 43%DUOHOME: Beats 63%
- Hot-day cooling efficiencyEER2AIR-CON: Beats 39%DUOHOME: Beats 47%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- AIR-CON
- 44%
- DUOHOME
- 87%
Xcel CC
- AIR-CON
- 34%
- DUOHOME
- 74%
CEE Advanced
- AIR-CON
- 0%
- DUOHOME
- 0%
ENERGY STAR CC
- AIR-CON
- 0%
- DUOHOME
- 0%
All-around best, ductless 2.5–3 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ductless, 2.5–3 tons (27,000–38,999 Btu/h cooling). What size is my system?
AIR-CON
- 1CH7H6C36KN-AEAIR-CON3 tons · 37,600 Btu/h · DuctlessNot a cold-climate pick: keeps 45% of its heat at 5°FMeets CEE 2025
- Heat kept at 5°F
- 45% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Top 10%
- Winter efficiency
- 9.6 (HSPF2)
- Below the middle
- Cooling efficiency
- 24.0 (SEER2)
- Top 10%
- Hot-day cooling
- 14.0 (EER2)
- Top 10%
- 2ASGCI8H4M36with ductless indoor unit ASGEC8H4M36AIR-CON3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 62.8Meets Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Top 10%
- Winter efficiency
- 10.3 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.6 (EER2)
- Below the middle
DUOHOME
- 1D5OD30-36HFN10-M1-DDUOHOMEAlso listed as D5OD30-36HFN10-M1D-D3 tons · 35,000 Btu/h · DuctlessCold-climate pick, score 47.2Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Good
- Cooling efficiency
- 23.1 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Good
- 2DOD30-36HFN10-M2with ductless indoor unit DCD-36HRFN10-M2-DDUOHOME3 tons · 36,000 Btu/h · DuctlessCold-climate pick, score 62.8Meets Xcel CC
- Heat kept at 5°F
- 70% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.20 (COP at 5°F)
- Top 10%
- Winter efficiency
- 10.3 (HSPF2)
- Good
- Cooling efficiency
- 20.0 (SEER2)
- Below the middle
- Hot-day cooling
- 9.6 (EER2)
- Below the middle
- 3DOD30-36HFN10-M1Ewith ductless indoor unit DSAG11FM-36HRFN10-M1E-DDUOHOME3 tons · 36,000 Btu/h · DuctlessNot a cold-climate pick: keeps 66% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 67% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.02 (COP at 5°F)
- Great
- Winter efficiency
- 9.1 (HSPF2)
- Below the middle
- Cooling efficiency
- 19.5 (SEER2)
- Below the middle
- Hot-day cooling
- 9.3 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.
Next steps
The advanced view adds ranks, both brands’ models inside every size class, standout models per rating and cold-weather curves.
Open the advanced view