Both views use the same certified data. This device remembers your choice.
AIR MAX vs GENERALLUX STAR heat pumps
Measured against models of the same size and duct type, AIR MAX and GENERALLUX STAR split the 6 ratings 3 to 3. AIR MAX has 7 outdoor models, GENERALLUX STAR has 7 outdoor models. AIR MAX and GENERALLUX STAR have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AIR MAX
- GENERALLUX STAR
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AIR MAX | GENERALLUX STAR |
|---|---|---|
| Efficiency index | 46% (higher)median — | 40% (higher)median — |
| COP at 5°F | 30% (higher)median 1.80 | 26% (higher)median 1.80 |
| Capacity retention at 5°F | 62% (higher)median 72% | 50% (higher)median 77% |
| HSPF2 | 17%median 8.5 | 32%median 8.6 |
| SEER2 | 46% (higher)median 20.0 | 36% (higher)median 20.5 |
| EER2 | 49%median 11.3 | 50%median 12.7 |
| Heating capacity at 5°F | 54%median 12,000 Btu/h | 55%median 11,900 Btu/h |
| Outdoor models | 7 | 7 |
| AHRI certifications | 7 | 7 |
Share of models meeting each standard
| Standard | AIR MAX | GENERALLUX STAR |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 57.1%4 models | 57.1%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 57.1%4 models | 57.1%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 42.9%3 models | 57.1%4 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AIR MAX
- GENERALLUX STAR
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AIR MAX | GENERALLUX STAR |
|---|---|---|
| Non-ducted, up to 1.5 tons | 4 · index 50% | 6 · index 44% |
| Non-ducted, 2 tons | 1 · index 26% | 1 · index 12% |
| Non-ducted, 2.5 to 3 tons | 2 · index 49% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AIR MAXCold-climate score, best model | GENERALLUX STARCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 51.6(50 is the typical model of its size class)AWGYC12-C2with ductless indoor unit AWGYE12-C2Also listed as AWGYC12-H24 of 4 models qualify · AHRI 205758359 | 59.7(50 is the typical model of its size class) (higher)GNS-12HCH23TO2with ductless indoor unit GNS-12HCH23TI24 of 6 models qualify · AHRI 213617768 |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5 to 3 tons | 45.9(50 is the typical model of its size class)AWGYC36-H2with ductless indoor unit AWGYE36-H21 of 2 models qualify · AHRI 211330205 | No models in this size class |
All-around best
| Size and duct type | AIR MAXAll-around score, best model | GENERALLUX STARAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | 68.8(50 is the typical model of its size class) (higher)AWGYC12-C2with ductless indoor unit AWGYE12-C2Also listed as AWGYC12-H24 of 4 models have all five ratings · AHRI 205758359 | 65.8(50 is the typical model of its size class)GNS-12HCH23TO2with ductless indoor unit GNS-12HCH23TI26 of 6 models have all five ratings · AHRI 213617768 |
| Non-ducted, 2 tons | 25.7(50 is the typical model of its size class) (higher)AWGSC24-H2with ductless indoor unit AWGSE24-H21 of 1 models have all five ratings · AHRI 204517336 | 11.6(50 is the typical model of its size class)AS-24UW3SBBTU(O)with ductless indoor unit AS-24UW3SBBTU(I)1 of 1 models have all five ratings · AHRI 206733683 |
| Non-ducted, 2.5 to 3 tons | 48.8(50 is the typical model of its size class)AWGYC36-H2with ductless indoor unit AWGYE36-H21 of 2 models have all five ratings · AHRI 211330205 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AIR MAX | GENERALLUX STAR |
|---|---|---|
| COP at 5°F | beats 56% · 1.85AWGYC36-H2Non-ducted, 2.5 to 3 tons | beats 48% · 1.89GNS-12HCH23TO2Non-ducted, up to 1.5 tons |
| Capacity retention at 5°F | beats 79% · 98%AWGYC12-C2Also listed as AWGYC12-H2Non-ducted, up to 1.5 tons | beats 73% · 86%GNS-18HCH21TO2Non-ducted, up to 1.5 tons |
| HSPF2 | beats 26% · 8.5AWGYC36-H2Non-ducted, 2.5 to 3 tons | beats 58% · 9.5GNS-12HCH22TO1Non-ducted, up to 1.5 tons |
| SEER2 | beats 83% · 24.0AWGYC12-C2Also listed as AWGYC12-H2Non-ducted, up to 1.5 tons | beats 79% · 23.5GNS-12HCH23TO2Non-ducted, up to 1.5 tons |
| EER2 | beats 85% · 14.0AWGYC12-C2Also listed as AWGYC12-H2Non-ducted, up to 1.5 tons | beats 75% · 13.2GNS-18HCH21TO2Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 70% · 12,000 Btu/hAWGYC12-C2Also listed as AWGYC12-H2Non-ducted, up to 1.5 tons | beats 88% · 15,500 Btu/hGNS-18HCH21TO2Non-ducted, up to 1.5 tons |