Skip to content

AIR TECH vs DNAIR heat pumps

Measured against models of the same size and duct type, AIR TECH and DNAIR split the 6 ratings 3–3. AIR TECH has 5 outdoor models, DNAIR has 5 outdoor models. AIR TECH and DNAIR have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AIR TECH and DNAIR on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AIR TECH and DNAIR split the 6 ratings 3–3.
  • AIR TECH
  • DNAIR
  • Other ranked manufacturers
AIR TECHDNAIR

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAIR TECHDNAIR
Efficiency index60% (higher)median —49% (higher)median —
COP at 5°F58% (higher)median 2.1050% (higher)median 1.95
Capacity retention at 5°F59%median 70%68%median 80%
HSPF237%median 9.078%median 9.5
SEER284% (higher)median 23.039% (higher)median 15.5
EER253% (higher)median 12.526% (higher)median 10.5
Heating capacity at 5°F60%median 25,200 Btu/h74%median 27,000 Btu/h
Outdoor models55
AHRI certifications119

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAIR TECHDNAIR
CEE 2025 Tier 1 (Split ASHP)100%5 models80%4 models
CEE 2026 Tier 1 (Split ASHP)100%5 models80%4 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)100%5 models80%4 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • AIR TECH
  • DNAIR
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsNon-ducted, 5 tons and up2.1032 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAIR TECHDNAIR
Ducted, 2.5–3 tons1 · index 67%2 · index 53%
Ducted, 3.5–4.5 tons1 · index 56%1 · index 37%
Ducted, 5 tons and up1 · index 54%None
Ducted, up to 1.5 tonsNone1 · index 52%
Ducted, 2 tonsNone1 · index 51%
Non-ducted, up to 1.5 tons2 · index 53%None
Non-ducted, 2.5–3 tons1 · index 77%None
Non-ducted, 3.5–4.5 tons1 · index 69%None
Non-ducted, 5 tons and up1 · index 50%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAIR TECHCold-climate score, best modelDNAIRCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class63.7(50 is the typical model of its size class)DNHP0018H-Cwith ducted air handler DNCL0018H-E1 of 1 models qualify · AHRI 213350746
Ducted, 2 tonsNo models in this size class66.5(50 is the typical model of its size class)DNHP0024H-Cwith ducted air handler DNHU0024H-E1 of 1 models qualify · AHRI 213350743
Ducted, 2.5–3 tons62.5(50 is the typical model of its size class)ATVO36NGUG21 of 1 models qualify · AHRI 21405655278.6(50 is the typical model of its size class) (higher)DNHP0036H-Cwith ducted air handler DNCL0036H-E2 of 2 models qualify · AHRI 213350749
Ducted, 3.5–4.5 tons52.8(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 21405654957.4(50 is the typical model of its size class) (higher)DNHP0048H-Cwith ducted air handler DNCL0048H-E1 of 1 models qualify · AHRI 213350750
Ducted, 5 tons and up55.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056547No models in this size class
Non-ducted, up to 1.5 tons46.5(50 is the typical model of its size class)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models qualify · AHRI 214010063No models in this size class
Non-ducted, 2.5–3 tons65.5(50 is the typical model of its size class)ATVO36NGUG21 of 1 models qualify · AHRI 214056553No models in this size class
Non-ducted, 3.5–4.5 tons57.5(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 214056550No models in this size class
Non-ducted, 5 tons and up36.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056546No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAIR TECHAll-around score, best modelDNAIRAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class63.4(50 is the typical model of its size class)DNHP0018H-Cwith ducted air handler DNHU0018H-E1 of 1 models have all five ratings · AHRI 213350742
Ducted, 2 tonsNo models in this size class65.8(50 is the typical model of its size class)DNHP0024H-Cwith ducted air handler DNHU0024H-E1 of 1 models have all five ratings · AHRI 213350743
Ducted, 2.5–3 tons67.0(50 is the typical model of its size class) (higher)ATVO36NGUG21 of 1 models have all five ratings · AHRI 21405655256.1(50 is the typical model of its size class)DNHP0036H-Cwith ducted air handler DNHU0036H-E2 of 2 models have all five ratings · AHRI 213350745
Ducted, 3.5–4.5 tons56.0(50 is the typical model of its size class) (higher)ATVO48NGUG21 of 1 models have all five ratings · AHRI 21405654937.0(50 is the typical model of its size class)DNHP0048H-Cwith ducted air handler DNCL0048H-E1 of 1 models have all five ratings · AHRI 213350750
Ducted, 5 tons and up53.9(50 is the typical model of its size class)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056547No models in this size class
Non-ducted, up to 1.5 tons56.9(50 is the typical model of its size class)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models have all five ratings · AHRI 214010063No models in this size class
Non-ducted, 2.5–3 tons77.0(50 is the typical model of its size class)ATVO36NGUG21 of 1 models have all five ratings · AHRI 214056553No models in this size class
Non-ducted, 3.5–4.5 tons69.0(50 is the typical model of its size class)ATVO48NGUG21 of 1 models have all five ratings · AHRI 214056550No models in this size class
Non-ducted, 5 tons and up49.5(50 is the typical model of its size class)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056546No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAIR TECHDNAIR
COP at 5°Fbeats 98% · 2.40ATVO36NGUG2Non-ducted, 2.5–3 tonsbeats 76% · 2.20DNHP0018H-CDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 88% · 70%ATVO60NGUG2Ducted, 5 tons and upbeats 74% · 86%DNHP0036H-CDucted, 2.5–3 tons
HSPF2beats 49% · 8.1ATVO48NGUG2Ducted, 3.5–4.5 tonsbeats 93% · 10.0DNHP0036H-CDucted, 2.5–3 tons
SEER2beats 86% · 17.0ATVO60NGUG2Ducted, 5 tons and upbeats 67% · 17.4DNHP0024H-CDucted, 2 tons
EER2beats 93% · 13.0ATVO36NGUG2Non-ducted, 2.5–3 tonsbeats 72% · 12.4DNHP0018H-CDucted, up to 1.5 tons
Heating capacity at 5°Fbeats 93% · 42,000 Btu/hATVO60NGUG2Ducted, 5 tons and upbeats 89% · 34,400 Btu/hDNHP0036H-CDucted, 2.5–3 tons

More comparisons