Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIR TECH vs LENNOX VRF heat pumps
Measured against models of the same size and duct type, AIR TECH scores higher on 5 of the 6 ratings. AIR TECH has 5 outdoor models, LENNOX VRF has 5 outdoor models. AIR TECH and LENNOX VRF have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AIR TECH
- LENNOX VRF
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AIR TECH | LENNOX VRF |
|---|---|---|
| Efficiency index | 60% (higher)median — | 40% (higher)median — |
| COP at 5°F | 58% (higher)median 2.10 | 42% (higher)median 2.20 |
| Capacity retention at 5°F | 59% (higher)median 70% | 10% (higher)median 50% |
| HSPF2 | 37%median 9.0 | 45%median 9.8 |
| SEER2 | 84% (higher)median 23.0 | 63% (higher)median 20.0 |
| EER2 | 53% (higher)median 12.5 | 33% (higher)median 10.5 |
| Heating capacity at 5°F | 60% (higher)median 25,200 Btu/h | 20% (higher)median 21,000 Btu/h |
| Outdoor models | 5 | 5 |
| AHRI certifications | 11 | 10 |
Share of models meeting each standard
| Standard | AIR TECH | LENNOX VRF |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%5 models | 20%1 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%5 models | 20%1 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%5 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AIR TECH
- LENNOX VRF
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AIR TECH | LENNOX VRF |
|---|---|---|
| Ducted, 2.5–3 tons | 1 · index 67% | 2 · index 35% |
| Ducted, 3.5–4.5 tons | 1 · index 56% | 1 · index 41% |
| Ducted, 5 tons and up | 1 · index 54% | 1 · index 52% |
| Ducted, 2 tons | None | 1 · index 37% |
| Non-ducted, up to 1.5 tons | 2 · index 53% | None |
| Non-ducted, 2.5–3 tons | 1 · index 77% | 2 · index 42% |
| Non-ducted, 3.5–4.5 tons | 1 · index 69% | 1 · index 61% |
| Non-ducted, 5 tons and up | 1 · index 50% | 1 · index 36% |
| Non-ducted, 2 tons | None | 1 · index 20% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AIR TECHCold-climate score, best model | LENNOX VRFCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Ducted, 2.5–3 tons | 62.5(50 is the typical model of its size class)ATVO36NGUG21 of 1 models qualify · AHRI 214056552 | None on this board (0 of 2 models qualify) |
| Ducted, 3.5–4.5 tons | 52.8(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 214056549 | None on this board (0 of 1 models qualify) |
| Ducted, 5 tons and up | 55.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056547 | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 46.5(50 is the typical model of its size class)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models qualify · AHRI 214010063 | No models in this size class |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5–3 tons | 65.5(50 is the typical model of its size class)ATVO36NGUG21 of 1 models qualify · AHRI 214056553 | None on this board (0 of 2 models qualify) |
| Non-ducted, 3.5–4.5 tons | 57.5(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 214056550 | None on this board (0 of 1 models qualify) |
| Non-ducted, 5 tons and up | 36.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056546 | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | AIR TECHAll-around score, best model | LENNOX VRFAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 37.2(50 is the typical model of its size class)VEP024C432P1 of 1 models have all five ratings · AHRI 206764034 |
| Ducted, 2.5–3 tons | 67.0(50 is the typical model of its size class) (higher)ATVO36NGUG21 of 1 models have all five ratings · AHRI 214056552 | 41.8(50 is the typical model of its size class)VEP036C432P22 of 2 models have all five ratings · AHRI 206764038 |
| Ducted, 3.5–4.5 tons | 56.0(50 is the typical model of its size class) (higher)ATVO48NGUG21 of 1 models have all five ratings · AHRI 214056549 | 41.4(50 is the typical model of its size class)VEP048C432P21 of 1 models have all five ratings · AHRI 206764040 |
| Ducted, 5 tons and up | 53.9(50 is the typical model of its size class) (higher)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056547 | 51.7(50 is the typical model of its size class)VEP060C432P21 of 1 models have all five ratings · AHRI 206764042 |
| Non-ducted, up to 1.5 tons | 56.9(50 is the typical model of its size class)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models have all five ratings · AHRI 214010063 | No models in this size class |
| Non-ducted, 2 tons | No models in this size class | 19.8(50 is the typical model of its size class)VEP024C432P1 of 1 models have all five ratings · AHRI 206764033 |
| Non-ducted, 2.5–3 tons | 77.0(50 is the typical model of its size class) (higher)ATVO36NGUG21 of 1 models have all five ratings · AHRI 214056553 | 61.7(50 is the typical model of its size class)VEP036C432P22 of 2 models have all five ratings · AHRI 206764037 |
| Non-ducted, 3.5–4.5 tons | 69.0(50 is the typical model of its size class) (higher)ATVO48NGUG21 of 1 models have all five ratings · AHRI 214056550 | 61.0(50 is the typical model of its size class)VEP048C432P21 of 1 models have all five ratings · AHRI 206764039 |
| Non-ducted, 5 tons and up | 49.5(50 is the typical model of its size class) (higher)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056546 | 36.2(50 is the typical model of its size class)VEP060C432P21 of 1 models have all five ratings · AHRI 206764041 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AIR TECH | LENNOX VRF |
|---|---|---|
| COP at 5°F | beats 98% · 2.40ATVO36NGUG2Non-ducted, 2.5–3 tons | beats 97% · 2.30VEP036C432P2Non-ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 88% · 70%ATVO60NGUG2Ducted, 5 tons and up | beats 33% · 48%VEP060C432P2Ducted, 5 tons and up |
| HSPF2 | beats 49% · 8.1ATVO48NGUG2Ducted, 3.5–4.5 tons | beats 72% · 9.8VEP036C432P2Non-ducted, 2.5–3 tons |
| SEER2 | beats 86% · 17.0ATVO60NGUG2Ducted, 5 tons and up | beats 96% · 18.0VEP060C432P2Ducted, 5 tons and up |
| EER2 | beats 93% · 13.0ATVO36NGUG2Non-ducted, 2.5–3 tons | beats 56% · 11.5VEP036C432P2Non-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 93% · 42,000 Btu/hATVO60NGUG2Ducted, 5 tons and up | beats 45% · 31,000 Btu/hVEP060C432P2Ducted, 5 tons and up |