Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
AIR TECH vs UA United Appliances heat pumps
Measured against models of the same size and duct type, AIR TECH scores higher on 6 of the 6 ratings. AIR TECH has 5 outdoor models, UA United Appliances has 13 outdoor models. AIR TECH and UA United Appliances have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AIR TECH
- UA United Appliances
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AIR TECH | UA United Appliances |
|---|---|---|
| Efficiency index | 60% (higher)median — | 27% (higher)median — |
| COP at 5°F | 58% (higher)median 2.10 | 16% (higher)median 1.76 |
| Capacity retention at 5°F | 59% (higher)median 70% | 43% (higher)median 60% |
| HSPF2 | 37% (higher)median 9.0 | 27% (higher)median 8.2 |
| SEER2 | 84% (higher)median 23.0 | 30% (higher)median 16.0 |
| EER2 | 53% (higher)median 12.5 | 22% (higher)median 10.0 |
| Heating capacity at 5°F | 60% (higher)median 25,200 Btu/h | 36% (higher)median 16,100 Btu/h |
| Outdoor models | 5 | 13 |
| AHRI certifications | 11 | 13 |
Share of models meeting each standard
| Standard | AIR TECH | UA United Appliances |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%5 models | 15.4%2 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%5 models | 15.4%2 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%5 models | 23.1%3 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AIR TECH
- UA United Appliances
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AIR TECH | UA United Appliances |
|---|---|---|
| Ducted, 2.5–3 tons | 1 · index 67% | 2 · index 28% |
| Ducted, 3.5–4.5 tons | 1 · index 56% | 3 · index 33% |
| Ducted, 5 tons and up | 1 · index 54% | None |
| Ducted, 2 tons | None | 1 · index 27% |
| Non-ducted, up to 1.5 tons | 2 · index 53% | 5 · index 16% |
| Non-ducted, 2.5–3 tons | 1 · index 77% | 2 · index 47% |
| Non-ducted, 3.5–4.5 tons | 1 · index 69% | None |
| Non-ducted, 5 tons and up | 1 · index 50% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AIR TECHCold-climate score, best model | UA United AppliancesCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | None on this board (0 of 1 models qualify) |
| Ducted, 2.5–3 tons | 62.5(50 is the typical model of its size class)ATVO36NGUG21 of 1 models qualify · AHRI 214056552 | None on this board (0 of 2 models qualify) |
| Ducted, 3.5–4.5 tons | 52.8(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 214056549 | None on this board (0 of 3 models qualify) |
| Ducted, 5 tons and up | 55.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056547 | No models in this size class |
| Non-ducted, up to 1.5 tons | 46.5(50 is the typical model of its size class) (higher)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models qualify · AHRI 214010063 | 28.8(50 is the typical model of its size class)UAWH09-DD3D1/Owith ductless indoor unit UAWH09-DD3D1/I4 of 5 models qualify · AHRI 213257467 |
| Non-ducted, 2.5–3 tons | 65.5(50 is the typical model of its size class) (higher)ATVO36NGUG21 of 1 models qualify · AHRI 214056553 | 44.1(50 is the typical model of its size class)UAWH36-DD3D1/Owith ductless indoor unit UAWH36-DD3D1/I2 of 2 models qualify · AHRI 213257471 |
| Non-ducted, 3.5–4.5 tons | 57.5(50 is the typical model of its size class)ATVO48NGUG21 of 1 models qualify · AHRI 214056550 | No models in this size class |
| Non-ducted, 5 tons and up | 36.0(50 is the typical model of its size class)ATVO60NGUG21 of 1 models qualify · AHRI 214056546 | No models in this size class |
All-around best
| Size and duct type | AIR TECHAll-around score, best model | UA United AppliancesAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 26.7(50 is the typical model of its size class)UADH24-DD3D1/Owith ducted air handler UADH24-DD3D1/I1 of 1 models have all five ratings · AHRI 213386663 |
| Ducted, 2.5–3 tons | 67.0(50 is the typical model of its size class) (higher)ATVO36NGUG21 of 1 models have all five ratings · AHRI 214056552 | 29.0(50 is the typical model of its size class)UADH36-DD3D1/Owith ducted air handler UADH36-DD3D1/I2 of 2 models have all five ratings · AHRI 213386665 |
| Ducted, 3.5–4.5 tons | 56.0(50 is the typical model of its size class) (higher)ATVO48NGUG21 of 1 models have all five ratings · AHRI 214056549 | 36.4(50 is the typical model of its size class)UADH42-DD3D1/Owith ducted air handler UADH42-DD3D1/I3 of 3 models have all five ratings · AHRI 213386666 |
| Ducted, 5 tons and up | 53.9(50 is the typical model of its size class)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056547 | No models in this size class |
| Non-ducted, up to 1.5 tons | 56.9(50 is the typical model of its size class) (higher)ATSO12NAMG2with ductless indoor unit ATSW12NAMG22 of 2 models have all five ratings · AHRI 214010063 | 23.2(50 is the typical model of its size class)UAWH09-AD3D1/Owith ductless indoor unit UAWH09-AD3D1/I5 of 5 models have all five ratings · AHRI 213257466 |
| Non-ducted, 2.5–3 tons | 77.0(50 is the typical model of its size class) (higher)ATVO36NGUG21 of 1 models have all five ratings · AHRI 214056553 | 47.8(50 is the typical model of its size class)UAWH36-DD3D1/Owith ductless indoor unit UAWH36-DD3D1/I2 of 2 models have all five ratings · AHRI 213257471 |
| Non-ducted, 3.5–4.5 tons | 69.0(50 is the typical model of its size class)ATVO48NGUG21 of 1 models have all five ratings · AHRI 214056550 | No models in this size class |
| Non-ducted, 5 tons and up | 49.5(50 is the typical model of its size class)ATVO60NGUG21 of 1 models have all five ratings · AHRI 214056546 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AIR TECH | UA United Appliances |
|---|---|---|
| COP at 5°F | beats 98% · 2.40ATVO36NGUG2Non-ducted, 2.5–3 tons | beats 53% · 1.85UAWH36-DD3D1/ONon-ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 88% · 70%ATVO60NGUG2Ducted, 5 tons and up | beats 65% · 79%UAWH09-DD3D1/ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 49% · 8.1ATVO48NGUG2Ducted, 3.5–4.5 tons | beats 39% · 7.8UADH42-DD3D1/ODucted, 3.5–4.5 tons |
| SEER2 | beats 86% · 17.0ATVO60NGUG2Ducted, 5 tons and up | beats 53% · 15.5UADH42-DD3D1/ODucted, 3.5–4.5 tons |
| EER2 | beats 93% · 13.0ATVO36NGUG2Non-ducted, 2.5–3 tons | beats 53% · 11.3UAWH30-DD3D1/ONon-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 93% · 42,000 Btu/hATVO60NGUG2Ducted, 5 tons and up | beats 59% · 11,500 Btu/hUAWH18-DD3D1/ONon-ducted, up to 1.5 tons |