Measured against models of the same size and duct type, Airlux and ATK split the 6 ratings 3 to 3. Airlux has 13 outdoor models, ATK has 13 outdoor models. Airlux and ATK have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Airlux
- ATK
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Airlux | ATK |
|---|---|---|
| Efficiency index | 63% (higher)median — | 47% (higher)median — |
| COP at 5°F | 57% (higher)median 2.04 | 51% (higher)median 1.91 |
| Capacity retention at 5°F | 44%median 68% | 57%median 79% |
| HSPF2 | 73%median 9.6 | 75%median 9.4 |
| SEER2 | 74% (higher)median 21.0 | 44% (higher)median 15.5 |
| EER2 | 58% (higher)median 12.2 | 20% (higher)median 10.0 |
| Heating capacity at 5°F | 43%median 16,500 Btu/h | 64%median 27,000 Btu/h |
| Outdoor models | 13 | 13 |
| AHRI certifications | 25 | 24 |
Share of models meeting each standard
| Standard | Airlux | ATK |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 76.9%10 models | 53.8%7 models |
| CEE 2026 Tier 1 (Split ASHP) | 69.2%9 models | 38.5%5 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 46.2%6 models | 46.2%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Airlux
- ATK
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Airlux | ATK |
|---|---|---|
| Ducted, up to 1.5 tons | 4 · index 69% | 2 · index 43% |
| Ducted, 2 tons | 1 · index 84% | 2 · index 49% |
| Ducted, 2.5 to 3 tons | 4 · index 55% | 5 · index 45% |
| Ducted, 3.5 to 4.5 tons | 2 · index 54% | 4 · index 50% |
| Non-ducted, up to 1.5 tons | 6 · index 67% | None |
| Non-ducted, 2 tons | 1 · index 57% | None |
| Non-ducted, 2.5 to 3 tons | 2 · index 62% | None |
| Non-ducted, 3.5 to 4.5 tons | 1 · index 48% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AirluxCold-climate score, best model | ATKCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 71.0(50 is the typical model of its size class) (higher)ASZ09O/2022with ducted air handler AMD09I3 of 4 models qualify · AHRI 208119665 | 64.2(50 is the typical model of its size class)ACI-AUO18SHP-Mwith ducted air handler ACI-BCO24CP171 of 2 models qualify · AHRI 212386850 |
| Ducted, 2 tons | 80.6(50 is the typical model of its size class) (higher)ASZ24O/2022with ducted air handler AMD24I1 of 1 models qualify · AHRI 208119668 | 69.9(50 is the typical model of its size class)ACI-AUO24SHP-Mwith ducted air handler ACI-AUI24VHE2 of 2 models qualify · AHRI 212386849 |
| Ducted, 2.5 to 3 tons | 57.6(50 is the typical model of its size class)AM3M27O/20221 of 4 models qualify · AHRI 208119676 | 78.7(50 is the typical model of its size class) (higher)ACI-AUO36SHP-Mwith ducted air handler ACI-CCO36CP213 of 5 models qualify · AHRI 212386847 |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 2 models qualify) | 74.0(50 is the typical model of its size class)ACI-AUO48SHP-Mwith ducted air handler ACI-AUI48VHE2 of 4 models qualify · AHRI 212386843 |
| Non-ducted, up to 1.5 tons | 81.1(50 is the typical model of its size class)ASZ09O/2022with ductless indoor unit AMM09I/20223 of 6 models qualify · AHRI 208119661 | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 51.5(50 is the typical model of its size class)AM3M27O/20221 of 2 models qualify · AHRI 208119675 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | None on this board (0 of 1 models qualify) | No models in this size class |
All-around best
| Size and duct type | AirluxAll-around score, best model | ATKAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 78.8(50 is the typical model of its size class) (higher)ASZ18O/2022with ducted air handler AMD18I4 of 4 models have all five ratings · AHRI 208119667 | 51.9(50 is the typical model of its size class)ACI-AUO18SHP-Mwith ducted air handler ACI-BCO24CP172 of 2 models have all five ratings · AHRI 212386850 |
| Ducted, 2 tons | 84.0(50 is the typical model of its size class) (higher)ASZ24O/2022with ducted air handler AMD24I1 of 1 models have all five ratings · AHRI 208119668 | 67.5(50 is the typical model of its size class)ACI-AUO24SHP-Mwith ducted air handler ACI-AUI24VHE2 of 2 models have all five ratings · AHRI 212386849 |
| Ducted, 2.5 to 3 tons | 71.7(50 is the typical model of its size class) (higher)AM3M27O/20223 of 4 models have all five ratings · AHRI 208119676 | 57.7(50 is the typical model of its size class)ACI-AUO36SHP-Mwith ducted air handler ACI-AUI36VHE5 of 5 models have all five ratings · AHRI 212386845 |
| Ducted, 3.5 to 4.5 tons | 63.5(50 is the typical model of its size class) (higher)AM5M48O/20222 of 2 models have all five ratings · AHRI 213199195 | 53.4(50 is the typical model of its size class)ACI-AUO48SHP-Mwith ducted air handler ACI-AUI48VHE3 of 3 models have all five ratings · AHRI 212386843 |
| Ducted, 5 tons and up | No models in this size class | 45.4(50 is the typical model of its size class)ACI-SDAUO60SHPwith ducted air handler ACI-AUI60VHE1 of 1 models have all five ratings · AHRI 213430648 |
| Non-ducted, up to 1.5 tons | 83.5(50 is the typical model of its size class)ASZ09O/2022with ductless indoor unit AMM09I/20226 of 6 models have all five ratings · AHRI 208119661 | No models in this size class |
| Non-ducted, 2 tons | 57.4(50 is the typical model of its size class)ASZ24O/2022with ductless indoor unit AMM24I/20221 of 1 models have all five ratings · AHRI 208119664 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 68.0(50 is the typical model of its size class)AM3M27O/20222 of 2 models have all five ratings · AHRI 208119675 | No models in this size class |
| Non-ducted, 3.5 to 4.5 tons | 48.3(50 is the typical model of its size class)AM5M48O/20221 of 1 models have all five ratings · AHRI 213199194 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Airlux | ATK |
|---|---|---|
| COP at 5°F | beats 96% · 2.38ASZ18O/2022Non-ducted, up to 1.5 tons | beats 76% · 2.20ACI-AUO18SHP-MDucted, up to 1.5 tons |
| Capacity retention at 5°F | beats 68% · 80%ASZ09O/2022Non-ducted, up to 1.5 tons | beats 92% · 92%ACI-AUO48SHP-MDucted, 3.5 to 4.5 tons |
| HSPF2 | beats 98% · 11.2ASZ24O/2022Ducted, 2 tons | beats 93% · 10.0ACI-AUO36SHP-MDucted, 2.5 to 3 tons |
| SEER2 | beats 98% · 21.0AM3M27O/2022Ducted, 2.5 to 3 tons | beats 68% · 17.3ACI-SDAUO30SHPDucted, 2.5 to 3 tons |
| EER2 | beats 85% · 12.5ASZ24O/2022Ducted, 2 tons | beats 50% · 11.7ACI-AUO24SHP-MDucted, 2 tons |
| Heating capacity at 5°F | beats 77% · 12,900 Btu/hAM2M18O/2022Non-ducted, up to 1.5 tons | beats 95% · 36,876 Btu/hACI-AUO36SHP-MDucted, 2.5 to 3 tons |