AIRTEMP vs Nutech heat pumps
Measured against models of the same size and duct type, AIRTEMP and Nutech split the 6 ratings 3–3. AIRTEMP has 25 outdoor models, Nutech has 25 outdoor models. AIRTEMP and Nutech have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- AIRTEMP
- Nutech
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | AIRTEMP | Nutech |
|---|---|---|
| Efficiency index | 45%median — | 51%median — |
| COP at 5°F | 32%median 1.81 | 37%median 1.90 |
| Capacity retention at 5°F | 65% (higher)median 77% | 42% (higher)median 65% |
| HSPF2 | 37%median 8.5 | 63%median 9.3 |
| SEER2 | 38%median 17.0 | 68%median 19.5 |
| EER2 | 44% (higher)median 11.0 | 42% (higher)median 10.6 |
| Heating capacity at 5°F | 63% (higher)median 19,800 Btu/h | 45% (higher)median 21,400 Btu/h |
| Outdoor models | 25 | 25 |
| AHRI certifications | 58 | 51 |
Share of models meeting each standard
| Standard | AIRTEMP | Nutech |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 48%12 models | 64%16 models |
| CEE 2026 Tier 1 (Split ASHP) | 48%12 models | 48%12 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 52%13 models | 32%8 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 32%8 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- AIRTEMP
- Nutech
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | AIRTEMP | Nutech |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index 31% | 4 · index 52% |
| Ducted, 2 tons | 3 · index 53% | 2 · index 69% |
| Ducted, 2.5–3 tons | 6 · index 52% | 7 · index 54% |
| Ducted, 3.5–4.5 tons | 4 · index 63% | 6 · index 55% |
| Ducted, 5 tons and up | None | 1 · index 42% |
| Non-ducted, up to 1.5 tons | 8 · index 28% | 4 · index 42% |
| Non-ducted, 2 tons | 2 · index 57% | 1 · index 27% |
| Non-ducted, 2.5–3 tons | 5 · index 60% | 5 · index 55% |
| Non-ducted, 3.5–4.5 tons | None | 4 · index 44% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | AIRTEMPCold-climate score, best model | NutechCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 35.6(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 2 models qualify · AHRI 210276818 | 65.4(50 is the typical model of its size class) (higher)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M3 of 4 models qualify · AHRI 212941749 |
| Ducted, 2 tons | 50.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-11 of 2 models qualify · AHRI 210276819 | 79.4(50 is the typical model of its size class) (higher)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models qualify · AHRI 212941751 |
| Ducted, 2.5–3 tons | 55.3(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH**-36MSK4DH14 of 7 models qualify · AHRI 206724409 | 57.4(50 is the typical model of its size class) (higher)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 7 models qualify · AHRI 212941759 |
| Ducted, 3.5–4.5 tons | 58.1(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 4 models qualify · AHRI 206724410 | None on this board (0 of 6 models qualify) |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 73.1(50 is the typical model of its size class) (higher)GXH18(5.3)FMK4DH-17 of 8 models qualify · AHRI 210276805 | 56.7(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU11 of 4 models qualify · AHRI 212941744 |
| Non-ducted, 2 tons | 76.1(50 is the typical model of its size class)GXH24(7.0)FMK4DH-12 of 2 models qualify · AHRI 210276806 | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5–3 tons | 73.7(50 is the typical model of its size class) (higher)GXH42(12.3)FMK4DH-15 of 5 models qualify · AHRI 210276804 | 49.3(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 5 models qualify · AHRI 212941758 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | None on this board (0 of 4 models qualify) |
All-around best
| Size and duct type | AIRTEMPAll-around score, best model | NutechAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 31.2(50 is the typical model of its size class)GXH18(5.3)FMK4DH-11 of 2 models have all five ratings · AHRI 210276818 | 64.5(50 is the typical model of its size class) (higher)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M4 of 4 models have all five ratings · AHRI 212941749 |
| Ducted, 2 tons | 60.8(50 is the typical model of its size class)GXH24-36MSK4DHwith ducted air handler GMH24-**MSK4DH12 of 3 models have all five ratings · AHRI 206724408 | 80.1(50 is the typical model of its size class) (higher)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models have all five ratings · AHRI 212941751 |
| Ducted, 2.5–3 tons | 53.1(50 is the typical model of its size class)GXH30(8.8)FMK4DH-13 of 6 models have all five ratings · AHRI 210276820 | 71.5(50 is the typical model of its size class) (higher)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M7 of 7 models have all five ratings · AHRI 212941759 |
| Ducted, 3.5–4.5 tons | 63.3(50 is the typical model of its size class)GXH48-60MSK4DHwith ducted air handler GMH48-**MSK4DH11 of 4 models have all five ratings · AHRI 206724410 | 63.5(50 is the typical model of its size class) (higher)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M6 of 6 models have all five ratings · AHRI 212941765 |
| Ducted, 5 tons and up | No models in this size class | 41.7(50 is the typical model of its size class)NOE30U-60HFN1-MR0with ducted air handler NVC-60HWFN11 of 1 models have all five ratings · AHRI 212941774 |
| Non-ducted, up to 1.5 tons | 58.0(50 is the typical model of its size class) (higher)GXH18(5.3)FMK4DH-18 of 8 models have all five ratings · AHRI 210276805 | 54.6(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU14 of 4 models have all five ratings · AHRI 212941744 |
| Non-ducted, 2 tons | 71.5(50 is the typical model of its size class) (higher)GXH24(7.0)FMK4DH-12 of 2 models have all five ratings · AHRI 210276806 | 27.2(50 is the typical model of its size class)NU24WKU1with ductless indoor unit NU24WKU11 of 1 models have all five ratings · AHRI 212941747 |
| Non-ducted, 2.5–3 tons | 70.2(50 is the typical model of its size class) (higher)GXH42(12.3)FMK4DH-15 of 5 models have all five ratings · AHRI 210276804 | 66.7(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M5 of 5 models have all five ratings · AHRI 212941758 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 48.3(50 is the typical model of its size class)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M4 of 4 models have all five ratings · AHRI 212941764 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | AIRTEMP | Nutech |
|---|---|---|
| COP at 5°F | beats 89% · 2.21GXH18(5.3)FMK4DH-1Non-ducted, up to 1.5 tons | beats 87% · 2.01NU36WKU1Non-ducted, 2.5–3 tons |
| Capacity retention at 5°F | beats 85% · 89%GXH30(8.8)FMK4DH-1Ducted, 2.5–3 tons | beats 92% · 108%NOD30-24HFN1-MU0WDucted, 2 tons |
| HSPF2 | beats 82% · 10.0GXH36(10.6)FMK4DH-1Non-ducted, 2.5–3 tons | beats 95% · 9.7N5OG-48HFN1-MAlso listed as N2OA-48HFN1-MDucted, 3.5–4.5 tons |
| SEER2 | beats 83% · 24.0GXH12(3.5)LSK4DH2Non-ducted, up to 1.5 tons | beats 98% · 21.0N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MDucted, 2.5–3 tons |
| EER2 | beats 84% · 12.5GXH30(8.8)FMK4DH-1Non-ducted, 2.5–3 tons | beats 75% · 12.2N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MNon-ducted, 2.5–3 tons |
| Heating capacity at 5°F | beats 86% · 14,500 Btu/hGXH18(5.3)LSK4DH2Non-ducted, up to 1.5 tons | beats 93% · 27,000 Btu/hNOD30-24HFN1-MU0WDucted, 2 tons |