Skip to content

Alsetria vs Innovair heat pumps

Measured against models of the same size and duct type, Alsetria scores higher on 4 of the 6 ratings. Alsetria has 50 outdoor models, Innovair has 48 outdoor models. Alsetria has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Alsetria and Innovair on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Alsetria scores higher on 4 of the 6 ratings.
  • Alsetria
  • Innovair
  • Other ranked manufacturers
AlsetriaInnovair

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAlsetriaInnovair
Efficiency index56% (higher)median —50% (higher)median — · 19th ranked
COP at 5°F55% (higher)median 1.9845% (higher)median 1.90 · 23rd ranked
Capacity retention at 5°F52%median 68%58%median 75% · 10th ranked
HSPF269% (higher)median 9.449% (higher)median 8.7 · 16th ranked
SEER262% (higher)median 19.047% (higher)median 17.0 · 16th ranked
EER245% (higher)median 10.941% (higher)median 10.5 · 25th ranked
Heating capacity at 5°F54%median 19,700 Btu/h59%median 19,400 Btu/h · 7th ranked
Outdoor models5048
AHRI certifications10095

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAlsetriaInnovair
CEE 2025 Tier 1 (Split ASHP)60%30 models50%24 models
CEE 2026 Tier 1 (Split ASHP)58%29 models45.8%22 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)42%21 models43.8%21 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate48%24 models47.9%23 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Alsetria
  • Innovair
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAlsetriaInnovair
Ducted, up to 1.5 tons10 · index 65%5 · index 54%
Ducted, 2 tons4 · index 72%5 · index 63%
Ducted, 2.5 to 3 tons12 · index 54%7 · index 51%
Ducted, 3.5 to 4.5 tons7 · index 52%6 · index 54%
Ducted, 5 tons and up2 · index 50%1 · index 42%
Non-ducted, up to 1.5 tons17 · index 54%14 · index 50%
Non-ducted, 2 tons5 · index 54%5 · index 55%
Non-ducted, 2.5 to 3 tons8 · index 54%8 · index 35%
Non-ducted, 3.5 to 4.5 tons3 · index 46%1 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAlsetriaCold-climate score, best modelInnovairCold-climate score, best model
Ducted, up to 1.5 tons87.0(50 is the typical model of its size class)MOX430U-18HFN1-Mwith ducted air handler MVBE-18HWFN1-MM3E8 of 10 models qualify · AHRI 21330791087.0(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R194 of 5 models qualify · AHRI 213255597
Ducted, 2 tons80.6(50 is the typical model of its size class) (higher)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models qualify · AHRI 21164402775.7(50 is the typical model of its size class)MHD-24with ducted air handler MHD-CC2.0-17.5-M4 of 5 models qualify · AHRI 210365430
Ducted, 2.5 to 3 tons80.0(50 is the typical model of its size class) (higher)MOE30U-36HFN1-M(GA)with ducted air handler MTI-36HWFN1-M5 of 12 models qualify · AHRI 21164404178.7(50 is the typical model of its size class)SHV36H2R20with ducted air handler MAC36H2124E4 of 7 models qualify · AHRI 213160476
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class) (higher)MOE30U-48HFN1-M-[X](GA)with ducted air handler MTI-48HWFN1-M4 of 7 models qualify · AHRI 21164404274.0(50 is the typical model of its size class)SHV48H2R20with ducted air handler DEV48H2R193 of 6 models qualify · AHRI 210343157
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W8 of 17 models qualify · AHRI 20812190080.8(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)7 of 14 models qualify · AHRI 206330207
Non-ducted, 2 tons87.1(50 is the typical model of its size class) (higher)MOD30-24HFN1-MU0Wwith ductless indoor unit MCD1-24HRFN1-MT0W(GA)2 of 5 models qualify · AHRI 21164404669.9(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)3 of 5 models qualify · AHRI 206330210
Non-ducted, 2.5 to 3 tons87.5(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X2 of 8 models qualify · AHRI 21330791265.0(50 is the typical model of its size class)VOM36H7R4P71 of 8 models qualify · AHRI 207821954
Non-ducted, 3.5 to 4.5 tons76.1(50 is the typical model of its size class) (higher)MOE30U-48HFN1-M-[X](GA)with ductless indoor unit MCD1-48HRFN1-M(GA)1 of 3 models qualify · AHRI 21164404841.8(50 is the typical model of its size class)VOM42H7R5P71 of 1 models qualify · AHRI 207821958

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAlsetriaAll-around score, best modelInnovairAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class) (higher)MOX330-09HFN1-MY5Wwith ducted air handler MTIU-09HWFN1-M10 of 10 models have all five ratings · AHRI 21164403782.9(50 is the typical model of its size class)SHV18H2R20with ducted air handler WEV18H2R195 of 5 models have all five ratings · AHRI 213255597
Ducted, 2 tons84.0(50 is the typical model of its size class) (higher)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M4 of 4 models have all five ratings · AHRI 21164402771.7(50 is the typical model of its size class)VOM24H7R3P75 of 5 models have all five ratings · AHRI 207821950
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X12 of 12 models have all five ratings · AHRI 21330791378.7(50 is the typical model of its size class)VOM36H7R4P77 of 7 models have all five ratings · AHRI 207821953
Ducted, 3.5 to 4.5 tons63.5(50 is the typical model of its size class) (higher)M5OG-48HFN1-M7 of 7 models have all five ratings · AHRI 20812191560.8(50 is the typical model of its size class)VOM42H7R5P76 of 6 models have all five ratings · AHRI 207821956
Ducted, 5 tons and up57.2(50 is the typical model of its size class) (higher)MOE30U-60HFN1-M(GA)(X)with ducted air handler MHG-60HWFN1-MW2 of 2 models have all five ratings · AHRI 21164403041.9(50 is the typical model of its size class)SEV60H2R19with ducted air handler DEV60H2R191 of 1 models have all five ratings · AHRI 208106863
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)MOX230-09HFN1-MW5Wwith ductless indoor unit MSEPB-06HRFN1-MY5W17 of 17 models have all five ratings · AHRI 20812190089.1(50 is the typical model of its size class)EIN10H2V32(O)with ductless indoor unit EIN10H2V32(I)11 of 14 models have all five ratings · AHRI 206330207
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)MOD30-24HFN1-MU0Wwith ductless indoor unit MSEPD-24HRFN1-MU0W5 of 5 models have all five ratings · AHRI 20812190477.1(50 is the typical model of its size class)EIN24H2V32(O)with ductless indoor unit EIN24H2V32(I)4 of 5 models have all five ratings · AHRI 206330210
Non-ducted, 2.5 to 3 tons78.9(50 is the typical model of its size class) (higher)M3OJ-27HFN1-M8 of 8 models have all five ratings · AHRI 20812190870.2(50 is the typical model of its size class)VOM36H7R4P77 of 8 models have all five ratings · AHRI 207821954
Non-ducted, 3.5 to 4.5 tons56.0(50 is the typical model of its size class) (higher)M5OG-48HFN1-M3 of 3 models have all five ratings · AHRI 20812191444.4(50 is the typical model of its size class)VOM42H7R5P71 of 1 models have all five ratings · AHRI 207821957

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAlsetriaInnovair
COP at 5°Fbeats 98% · 2.45MOX230-12HFN1-MV5WNon-ducted, up to 1.5 tonsbeats 91% · 2.37VEA36H2V18Ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 95% · 113%MOX230-09HFN1-MW5WNon-ducted, up to 1.5 tonsbeats 99% · 144%EIN10H2V32(O)Non-ducted, up to 1.5 tons
HSPF2beats 99% · 10.3MOE30U-48HFN1-M-[X](GA)Ducted, 3.5 to 4.5 tonsbeats 93% · 10.8SHV18H2R20Ducted, up to 1.5 tons
SEER2beats 99% · 24.6M3OJ-27HFN1-MNon-ducted, 2.5 to 3 tonsbeats 96% · 21.0VOM24H7R3P7Ducted, 2 tons
EER2beats 98% · 16.2MOX330-09HFN1-MY5WNon-ducted, up to 1.5 tonsbeats 99% · 16.6EIN10H2V32(O)Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 41,000 Btu/hMOE30U-36HFN1-M(GA)Non-ducted, 2.5 to 3 tonsbeats 96% · 20,000 Btu/hEIN18H2V32(O)Non-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Alsetria vs Innovair: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Alsetria (median, middle 50%)
  • Innovair (median, middle 50%)
Heating capacity, % of its 47°F maximum63%75%COP at maximum capacity1.981.90

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
Alsetria: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Alsetria, 47°F43100%100%100%100%100%
Alsetria, 17°F4363%67%71%78%86%
Alsetria, 5°F4352%56%63%70%80%
Alsetria: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Alsetria, 47°F432.732.873.063.353.51
Alsetria, 17°F431.982.12.232.322.49
Alsetria, 5°F431.81.91.982.042.21
Innovair: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Innovair, 47°F29100%100%100%100%100%
Innovair, 17°F2964%70%82%88%95%
Innovair, 5°F2957%63%75%81%84%
Innovair: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Innovair, 47°F292.312.533.043.323.5
Innovair, 17°F291.8822.22.322.42
Innovair, 5°F291.81.841.922.11

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter