Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
APLUS vs E COLD heat pumps
Measured against models of the same size and duct type, E COLD scores higher on 3 of the 6 ratings. APLUS has 5 outdoor models, E COLD has 5 outdoor models. APLUS and E COLD have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- APLUS
- E COLD
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | APLUS | E COLD |
|---|---|---|
| Efficiency index | —median — | 55%median — |
| COP at 5°F | —median — | 28%median 1.80 |
| Capacity retention at 5°F | —median — | 45%median 69% |
| HSPF2 | 21%median 7.5 | 62%median 9.5 |
| SEER2 | 13%median 14.3 | 77%median 21.1 |
| EER2 | 51%median 11.5 | 53%median 10.6 |
| Heating capacity at 5°F | —median — | 44%median 25,600 Btu/h |
| Outdoor models | 5 | 5 |
| AHRI certifications | 9 | 26 |
Share of models meeting each standard
| Standard | APLUS | E COLD |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 80%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 60%3 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 40%2 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- APLUS
- E COLD
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | APLUS | E COLD |
|---|---|---|
| Ducted, up to 1.5 tons | 1 · index — | None |
| Ducted, 2 tons | 2 · index — | None |
| Ducted, 2.5–3 tons | 2 · index — | 2 · index 64% |
| Ducted, 3.5–4.5 tons | None | 2 · index 58% |
| Non-ducted, 2.5–3 tons | None | 3 · index 53% |
| Non-ducted, 3.5–4.5 tons | None | 2 · index 46% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | APLUSCold-climate score, best model | E COLDCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Ducted, 2 tons | None on this board (0 of 2 models qualify) | No models in this size class |
| Ducted, 2.5–3 tons | None on this board (0 of 2 models qualify) | 57.8(50 is the typical model of its size class)ECOLD-C27-MS-G00011 of 2 models qualify · AHRI 213350752 |
| Ducted, 3.5–4.5 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, 2.5–3 tons | No models in this size class | 50.1(50 is the typical model of its size class)ECOLD-C27-MS-G00011 of 3 models qualify · AHRI 213350751 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 39.4(50 is the typical model of its size class)ECOLD-C48-MS-G00011 of 2 models qualify · AHRI 213350757 |
All-around best
| Size and duct type | APLUSAll-around score, best model | E COLDAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | None on this board (0 of 1 models have all five ratings) | No models in this size class |
| Ducted, 2 tons | None on this board (0 of 2 models have all five ratings) | No models in this size class |
| Ducted, 2.5–3 tons | None on this board (0 of 2 models have all five ratings) | 71.7(50 is the typical model of its size class)ECOLD-C27-MS-G00012 of 2 models have all five ratings · AHRI 213350752 |
| Ducted, 3.5–4.5 tons | No models in this size class | 63.5(50 is the typical model of its size class)ECOLD-C48-MS-G00012 of 2 models have all five ratings · AHRI 213350758 |
| Non-ducted, 2.5–3 tons | No models in this size class | 67.1(50 is the typical model of its size class)ECOLD-C27-MS-G00013 of 3 models have all five ratings · AHRI 213350751 |
| Non-ducted, 3.5–4.5 tons | No models in this size class | 51.7(50 is the typical model of its size class)ECOLD-C48-MS-G00012 of 2 models have all five ratings · AHRI 213350757 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | APLUS | E COLD |
|---|---|---|
| COP at 5°F | — | beats 87% · 2.01ECOLD-C36BRISA-G002Non-ducted, 2.5–3 tons |
| Capacity retention at 5°F | — | beats 57% · 71%ECOLD-C27-MS-G0001Non-ducted, 2.5–3 tons |
| HSPF2 | beats 21% · 7.5ATD-HF30SMR1-A01/SE143Ducted, 2.5–3 tons | beats 95% · 9.7ECOLD-C48-MS-G0001Ducted, 3.5–4.5 tons |
| SEER2 | beats 13% · 14.3ATD-HF30SMR1-A01/SE143Ducted, 2.5–3 tons | beats 98% · 21.0ECOLD-C27-MS-G0001Ducted, 2.5–3 tons |
| EER2 | beats 57% · 11.5ATD-HF30SMR1-A01/SE143Ducted, 2.5–3 tons | beats 75% · 12.2ECOLD-C27-MS-G0001Non-ducted, 2.5–3 tons |
| Heating capacity at 5°F | — | beats 69% · 25,600 Btu/hECOLD-C36-MS-G0001Non-ducted, 2.5–3 tons |