ARCTIC KING vs Buck Cool heat pumps
Measured against models of the same size and duct type, Buck Cool scores higher on 6 of the 6 ratings. ARCTIC KING has 5 outdoor models, Buck Cool has 5 outdoor models. ARCTIC KING and Buck Cool have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- ARCTIC KING
- Buck Cool
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | ARCTIC KING | Buck Cool |
|---|---|---|
| Efficiency index | 35%median — | 55%median — |
| COP at 5°F | 40%median 1.85 | 60%median 1.98 |
| Capacity retention at 5°F | 28%median 64% | 70%median 81% |
| HSPF2 | 29%median 9.0 | 33%median 8.6 |
| SEER2 | 23%median 17.0 | 43%median 20.5 |
| EER2 | 27%median 9.0 | 48%median 12.5 |
| Heating capacity at 5°F | 29%median 15,900 Btu/h | 55%median 11,715 Btu/h |
| Outdoor models | 5 | 5 |
| AHRI certifications | 5 | 5 |
Share of models meeting each standard
| Standard | ARCTIC KING | Buck Cool |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 20%1 models | 80%4 models |
| CEE 2026 Tier 1 (Split ASHP) | 20%1 models | 80%4 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 80%4 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 60%3 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- ARCTIC KING
- Buck Cool
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | ARCTIC KING | Buck Cool |
|---|---|---|
| Non-ducted, 2 tons | 2 · index 35% | 1 · index 59% |
| Non-ducted, 2.5–3 tons | 1 · index — | 1 · index — |
| Non-ducted, 3.5–4.5 tons | 2 · index — | None |
| Non-ducted, up to 1.5 tons | None | 3 · index 54% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | ARCTIC KINGCold-climate score, best model | Buck CoolCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | No models in this size class | 62.1(50 is the typical model of its size class)UB1MSHQCO09with ductless indoor unit UB1MSHQCW093 of 3 models qualify · AHRI 208287570 |
| Non-ducted, 2 tons | None on this board (0 of 2 models qualify) | 64.0(50 is the typical model of its size class)UB1MSHQCO24with ductless indoor unit UB1MSHQCW241 of 1 models qualify · AHRI 208287576 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, 3.5–4.5 tons | None on this board (0 of 2 models qualify) | No models in this size class |
All-around best
| Size and duct type | ARCTIC KINGAll-around score, best model | Buck CoolAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | No models in this size class | 56.5(50 is the typical model of its size class)UB1MSHQCO18with ductless indoor unit UB1MSHQCW183 of 3 models have all five ratings · AHRI 208287574 |
| Non-ducted, 2 tons | 56.4(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ductless indoor unit MSAG11D-23HRFN1-MU0W2 of 2 models have all five ratings · AHRI 207821945 | 58.5(50 is the typical model of its size class) (higher)UB1MSHQCO24with ductless indoor unit UB1MSHQCW241 of 1 models have all five ratings · AHRI 208287576 |
| Non-ducted, 2.5–3 tons | None on this board (0 of 1 models have all five ratings) | None on this board (0 of 1 models have all five ratings) |
| Non-ducted, 3.5–4.5 tons | None on this board (0 of 2 models have all five ratings) | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | ARCTIC KING | Buck Cool |
|---|---|---|
| COP at 5°F | beats 55% · 1.90MOD33-24HFN1-MT0WNon-ducted, 2 tons | beats 81% · 2.13UB1MSHQCO24Non-ducted, 2 tons |
| Capacity retention at 5°F | beats 29% · 64%MOD33-24HFN1-MT0WNon-ducted, 2 tons | beats 69% · 89%UB1MSHQCO24Non-ducted, 2 tons |
| HSPF2 | beats 57% · 9.3MOD30U-36HFN1-MNon-ducted, 2.5–3 tons | beats 57% · 9.5UB1MSHQCO12Non-ducted, up to 1.5 tons |
| SEER2 | beats 66% · 21.0MOD33-24HFN1-MT0WNon-ducted, 2 tons | beats 67% · 22.5UB1MSHQCO18Non-ducted, up to 1.5 tons |
| EER2 | beats 84% · 13.0MOD33-24HFN1-MT0WNon-ducted, 2 tons | beats 68% · 13.0UB1MSHQCO18Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 35% · 16,700 Btu/hMOD33-24HFN1-MT0WNon-ducted, 2 tons | beats 83% · 13,770 Btu/hUB1MSHQCO18Non-ducted, up to 1.5 tons |