Skip to content

ARCTIC KING vs LENNOX VRF heat pumps

Measured against models of the same size and duct type, ARCTIC KING and LENNOX VRF split the 6 ratings 3 to 3. ARCTIC KING has 5 outdoor models, LENNOX VRF has 5 outdoor models. ARCTIC KING and LENNOX VRF have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ARCTIC KING and LENNOX VRF on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ARCTIC KING and LENNOX VRF split the 6 ratings 3 to 3.
  • ARCTIC KING
  • LENNOX VRF
  • Other ranked manufacturers
ARCTIC K…LENNOX V…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingARCTIC KINGLENNOX VRF
Efficiency index41%median —41%median —
COP at 5°F64% (higher)median 2.0143% (higher)median 2.20
Capacity retention at 5°F41% (higher)median 69%10% (higher)median 50%
HSPF229%median 9.045%median 9.8
SEER223%median 17.063%median 20.0
EER227%median 9.034%median 10.5
Heating capacity at 5°F42% (higher)median 17,321 Btu/h21% (higher)median 21,000 Btu/h
Outdoor models55
AHRI certifications510

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardARCTIC KINGLENNOX VRF
CEE 2025 Tier 1 (Split ASHP)20%1 models20%1 models
CEE 2026 Tier 1 (Split ASHP)20%1 models20%1 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)20%1 models0%0 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • ARCTIC KING
  • LENNOX VRF
  • All models of the group
Ducted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsNon-ducted, 5 tons and up2.0137 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeARCTIC KINGLENNOX VRF
Ducted, 2 tonsNone1 · index 37%
Ducted, 2.5 to 3 tonsNone2 · index 36%
Ducted, 3.5 to 4.5 tonsNone1 · index 42%
Ducted, 5 tons and upNone1 · index 52%
Non-ducted, 2 tons2 · index 41%1 · index 21%
Non-ducted, 2.5 to 3 tons1 · index —2 · index 42%
Non-ducted, 3.5 to 4.5 tons2 · index —1 · index 61%
Non-ducted, 5 tons and upNone1 · index 40%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeARCTIC KINGCold-climate score, best modelLENNOX VRFCold-climate score, best model
Ducted, 2 tonsNo models in this size classNone on this board (0 of 1 models qualify)
Ducted, 2.5 to 3 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Ducted, 3.5 to 4.5 tonsNo models in this size classNone on this board (0 of 1 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, 2 tons56.8(50 is the typical model of its size class)MOD33-24HFN1-MT0Wwith ductless indoor unit MSAG11D-23HRFN1-MU0W1 of 2 models qualify · AHRI 207821945None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeARCTIC KINGAll-around score, best modelLENNOX VRFAll-around score, best model
Ducted, 2 tonsNo models in this size class37.4(50 is the typical model of its size class)VEP024C432P1 of 1 models have all five ratings · AHRI 206764034
Ducted, 2.5 to 3 tonsNo models in this size class41.8(50 is the typical model of its size class)VEP036C432P22 of 2 models have all five ratings · AHRI 206764038
Ducted, 3.5 to 4.5 tonsNo models in this size class41.7(50 is the typical model of its size class)VEP048C432P21 of 1 models have all five ratings · AHRI 206764040
Ducted, 5 tons and upNo models in this size class52.3(50 is the typical model of its size class)VEP060C432P21 of 1 models have all five ratings · AHRI 206764042
Non-ducted, 2 tons67.4(50 is the typical model of its size class) (higher)MOD33-24HFN1-MT0Wwith ductless indoor unit MSAG11D-23HRFN1-MU0W2 of 2 models have all five ratings · AHRI 20782194520.5(50 is the typical model of its size class)VEP024C432P1 of 1 models have all five ratings · AHRI 206764033
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 1 models have all five ratings)62.0(50 is the typical model of its size class)VEP036C432P22 of 2 models have all five ratings · AHRI 206764037
Non-ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models have all five ratings)61.0(50 is the typical model of its size class)VEP048C432P21 of 1 models have all five ratings · AHRI 206764039
Non-ducted, 5 tons and upNo models in this size class39.7(50 is the typical model of its size class)VEP060C432P21 of 1 models have all five ratings · AHRI 206764041

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingARCTIC KINGLENNOX VRF
COP at 5°Fbeats 97% · 2.22MOD33-24HFN1-MT0WNon-ducted, 2 tonsbeats 97% · 2.30VEP036C432P2Non-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 49% · 75%MOD33-24HFN1-MT0WNon-ducted, 2 tonsbeats 34% · 48%VEP060C432P2Ducted, 5 tons and up
HSPF2beats 57% · 9.3MOD30U-36HFN1-MNon-ducted, 2.5 to 3 tonsbeats 72% · 9.8VEP036C432P2Non-ducted, 2.5 to 3 tons
SEER2beats 66% · 21.0MOD33-24HFN1-MT0WNon-ducted, 2 tonsbeats 96% · 18.0VEP060C432P2Ducted, 5 tons and up
EER2beats 85% · 13.0MOD33-24HFN1-MT0WNon-ducted, 2 tonsbeats 56% · 11.5VEP036C432P2Non-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 58% · 19,542 Btu/hMOD33-24HFN1-MT0WNon-ducted, 2 tonsbeats 45% · 31,000 Btu/hVEP060C432P2Ducted, 5 tons and up

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter