Skip to content

ARMSCO vs GENERALLUX STAR heat pumps

Measured against models of the same size and duct type, GENERALLUX STAR scores higher on 6 of the 6 ratings. ARMSCO has 7 outdoor models, GENERALLUX STAR has 7 outdoor models. ARMSCO and GENERALLUX STAR have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ARMSCO and GENERALLUX STAR on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, GENERALLUX STAR scores higher on 6 of the 6 ratings.
  • ARMSCO
  • GENERALLUX STAR
  • Other ranked manufacturers
ARMSCOGENERALL…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingARMSCOGENERALLUX STAR
Efficiency index22%median —58%median —
COP at 5°F19%median 1.8037%median 1.86
Capacity retention at 5°F30%median 70%69%median 82%
HSPF219%median 8.531%median 8.6
SEER227%median 19.036%median 20.5
EER216%median 10.050%median 12.7
Heating capacity at 5°F32%median 8,600 Btu/h68%median 11,885 Btu/h
Outdoor models77
AHRI certifications77

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardARMSCOGENERALLUX STAR
CEE 2025 Tier 1 (Split ASHP)71.4%5 models57.1%4 models
CEE 2026 Tier 1 (Split ASHP)57.1%4 models57.1%4 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)57.1%4 models57.1%4 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 2 groups where both have models
  • ARMSCO
  • GENERALLUX STAR
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeARMSCOGENERALLUX STAR
Non-ducted, up to 1.5 tons5 · index 21%6 · index 58%
Non-ducted, 2 tons1 · index 25%1 · index —
Non-ducted, 2.5–3 tons1 · index 23%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeARMSCOCold-climate score, best modelGENERALLUX STARCold-climate score, best model
Non-ducted, up to 1.5 tons28.4(50 is the typical model of its size class)ACMS122419AAwith ductless indoor unit ACMS122419AAAlso listed as ACMS122420AB4 of 5 models qualify · AHRI 21382985858.2(50 is the typical model of its size class) (higher)GNS-12HCH23TO2with ductless indoor unit GNS-12HCH23TI24 of 6 models qualify · AHRI 213617768
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, 2.5–3 tonsNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeARMSCOAll-around score, best modelGENERALLUX STARAll-around score, best model
Non-ducted, up to 1.5 tons23.6(50 is the typical model of its size class)ACMS122419AAwith ductless indoor unit ACMS122419AAAlso listed as ACMS122420AB5 of 5 models have all five ratings · AHRI 21382985865.0(50 is the typical model of its size class) (higher)GNS-12HCH23TO2with ductless indoor unit GNS-12HCH23TI24 of 6 models have all five ratings · AHRI 213617768
Non-ducted, 2 tons24.8(50 is the typical model of its size class)ACMS242420ABwith ductless indoor unit ACMS242420AB1 of 1 models have all five ratings · AHRI 213829862None on this board (0 of 1 models have all five ratings)
Non-ducted, 2.5–3 tons23.4(50 is the typical model of its size class)ACMS362420ABwith ductless indoor unit ACMS362420AB1 of 1 models have all five ratings · AHRI 213829863No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingARMSCOGENERALLUX STAR
COP at 5°Fbeats 26% · 1.80ACMS242420ABNon-ducted, 2 tonsbeats 46% · 1.89GNS-12HCH23TO2Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 46% · 70%ACMS122419AAAlso listed as ACMS122420ABNon-ducted, up to 1.5 tonsbeats 72% · 86%GNS-18HCH21TO2Non-ducted, up to 1.5 tons
HSPF2beats 25% · 8.5ACMS362420ABNon-ducted, 2.5–3 tonsbeats 57% · 9.5GNS-12HCH22TO1Non-ducted, up to 1.5 tons
SEER2beats 35% · 19.0ACMS362420ABNon-ducted, 2.5–3 tonsbeats 79% · 23.5GNS-12HCH23TO2Non-ducted, up to 1.5 tons
EER2beats 25% · 10.0ACMS242420ABNon-ducted, 2 tonsbeats 74% · 13.2GNS-18HCH21TO2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 61% · 11,600 Btu/hACMS182420ABNon-ducted, up to 1.5 tonsbeats 88% · 15,500 Btu/hGNS-18HCH21TO2Non-ducted, up to 1.5 tons

More comparisons