Skip to content

ATK vs UA United Appliances heat pumps

Measured against models of the same size and duct type, ATK scores higher on 5 of the 6 ratings. ATK has 13 outdoor models, UA United Appliances has 13 outdoor models. ATK and UA United Appliances have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
ATK and UA United Appliances on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, ATK scores higher on 5 of the 6 ratings.
  • ATK
  • UA United Appliances
  • Other ranked manufacturers
ATKUA Unite…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingATKUA United Appliances
Efficiency index47% (higher)median —27% (higher)median —
COP at 5°F51% (higher)median 1.9116% (higher)median 1.76
Capacity retention at 5°F57% (higher)median 79%43% (higher)median 60%
HSPF275% (higher)median 9.427% (higher)median 8.2
SEER244% (higher)median 15.530% (higher)median 16.0
EER220%median 10.022%median 10.0
Heating capacity at 5°F64% (higher)median 27,000 Btu/h36% (higher)median 16,100 Btu/h
Outdoor models1313
AHRI certifications2413

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardATKUA United Appliances
CEE 2025 Tier 1 (Split ASHP)53.8%7 models15.4%2 models
CEE 2026 Tier 1 (Split ASHP)38.5%5 models15.4%2 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)46.2%6 models23.1%3 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 3 groups where both have models
  • ATK
  • UA United Appliances
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeATKUA United Appliances
Ducted, up to 1.5 tons2 · index 43%None
Ducted, 2 tons2 · index 49%1 · index 27%
Ducted, 2.5–3 tons5 · index 45%2 · index 28%
Ducted, 3.5–4.5 tons4 · index 50%3 · index 33%
Non-ducted, up to 1.5 tonsNone5 · index 16%
Non-ducted, 2.5–3 tonsNone2 · index 47%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeATKCold-climate score, best modelUA United AppliancesCold-climate score, best model
Ducted, up to 1.5 tons64.3(50 is the typical model of its size class)ACI-AUO18SHP-Mwith ducted air handler ACI-BCO24CP171 of 2 models qualify · AHRI 212386850No models in this size class
Ducted, 2 tons69.5(50 is the typical model of its size class)ACI-AUO24SHP-Mwith ducted air handler ACI-AUI24VHE2 of 2 models qualify · AHRI 212386849None on this board (0 of 1 models qualify)
Ducted, 2.5–3 tons78.6(50 is the typical model of its size class)ACI-AUO36SHP-Mwith ducted air handler ACI-CCO36CP213 of 5 models qualify · AHRI 212386847None on this board (0 of 2 models qualify)
Ducted, 3.5–4.5 tons73.8(50 is the typical model of its size class)ACI-AUO48SHP-Mwith ducted air handler ACI-AUI48VHE2 of 4 models qualify · AHRI 212386843None on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tonsNo models in this size class28.8(50 is the typical model of its size class)UAWH09-DD3D1/Owith ductless indoor unit UAWH09-DD3D1/I4 of 5 models qualify · AHRI 213257467
Non-ducted, 2.5–3 tonsNo models in this size class44.1(50 is the typical model of its size class)UAWH36-DD3D1/Owith ductless indoor unit UAWH36-DD3D1/I2 of 2 models qualify · AHRI 213257471

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeATKAll-around score, best modelUA United AppliancesAll-around score, best model
Ducted, up to 1.5 tons51.9(50 is the typical model of its size class)ACI-AUO18SHP-Mwith ducted air handler ACI-BCO24CP172 of 2 models have all five ratings · AHRI 212386850No models in this size class
Ducted, 2 tons67.3(50 is the typical model of its size class) (higher)ACI-AUO24SHP-Mwith ducted air handler ACI-AUI24VHE2 of 2 models have all five ratings · AHRI 21238684926.7(50 is the typical model of its size class)UADH24-DD3D1/Owith ducted air handler UADH24-DD3D1/I1 of 1 models have all five ratings · AHRI 213386663
Ducted, 2.5–3 tons57.8(50 is the typical model of its size class) (higher)ACI-AUO36SHP-Mwith ducted air handler ACI-AUI36VHE5 of 5 models have all five ratings · AHRI 21238684529.0(50 is the typical model of its size class)UADH36-DD3D1/Owith ducted air handler UADH36-DD3D1/I2 of 2 models have all five ratings · AHRI 213386665
Ducted, 3.5–4.5 tons53.3(50 is the typical model of its size class) (higher)ACI-AUO60SHP-Mwith ducted air handler ACI-AUI60VHE3 of 3 models have all five ratings · AHRI 21238684236.4(50 is the typical model of its size class)UADH42-DD3D1/Owith ducted air handler UADH42-DD3D1/I3 of 3 models have all five ratings · AHRI 213386666
Ducted, 5 tons and up45.6(50 is the typical model of its size class)ACI-SDAUO60SHPwith ducted air handler ACI-AUI60VHE1 of 1 models have all five ratings · AHRI 213430648No models in this size class
Non-ducted, up to 1.5 tonsNo models in this size class23.2(50 is the typical model of its size class)UAWH09-AD3D1/Owith ductless indoor unit UAWH09-AD3D1/I5 of 5 models have all five ratings · AHRI 213257466
Non-ducted, 2.5–3 tonsNo models in this size class47.8(50 is the typical model of its size class)UAWH36-DD3D1/Owith ductless indoor unit UAWH36-DD3D1/I2 of 2 models have all five ratings · AHRI 213257471

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingATKUA United Appliances
COP at 5°Fbeats 76% · 2.20ACI-AUO18SHP-MDucted, up to 1.5 tonsbeats 53% · 1.85UAWH36-DD3D1/ONon-ducted, 2.5–3 tons
Capacity retention at 5°Fbeats 92% · 92%ACI-AUO48SHP-MDucted, 3.5–4.5 tonsbeats 65% · 79%UAWH09-DD3D1/ONon-ducted, up to 1.5 tons
HSPF2beats 93% · 10.0ACI-AUO36SHP-MDucted, 2.5–3 tonsbeats 39% · 7.8UADH42-DD3D1/ODucted, 3.5–4.5 tons
SEER2beats 69% · 17.3ACI-SDAUO30SHPDucted, 2.5–3 tonsbeats 53% · 15.5UADH42-DD3D1/ODucted, 3.5–4.5 tons
EER2beats 50% · 11.7ACI-AUO24SHP-MDucted, 2 tonsbeats 53% · 11.3UAWH30-DD3D1/ONon-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 95% · 48,500 Btu/hACI-AUO60SHP-MDucted, 3.5–4.5 tonsbeats 59% · 11,500 Btu/hUAWH18-DD3D1/ONon-ducted, up to 1.5 tons

More comparisons