Measured against models of the same size and duct type, AURUS scores higher on 4 of the 6 ratings. AURUS has 12 outdoor models, SLIMAIR TECHNOLOGIES has 12 outdoor models. AURUS and SLIMAIR TECHNOLOGIES have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
AURUS and SLIMAIR TECHNOLOGIES on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, AURUS scores higher on 4 of the 6 ratings.
  • AURUS
  • SLIMAIR TECHNOLOGIES
  • Other ranked manufacturers
AURUSSLIMAIR …

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingAURUSSLIMAIR TECHNOLOGIES
Efficiency index36% (higher)median —27% (higher)median —
COP at 5°F39% (higher)median 1.809% (higher)median 1.75
Capacity retention at 5°F41% (higher)median 69%24% (higher)median 65%
HSPF230%median 8.530%median 8.6
SEER241% (higher)median 19.030% (higher)median 16.8
EER215%median 10.037%median 10.6
Heating capacity at 5°F50% (higher)median 15,000 Btu/h27% (higher)median 11,900 Btu/h
Outdoor models1212
AHRI certifications1212

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardAURUSSLIMAIR TECHNOLOGIES
CEE 2025 Tier 1 (Split ASHP)50%6 models41.7%5 models
CEE 2026 Tier 1 (Split ASHP)41.7%5 models33.3%4 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)33.3%4 models8.3%1 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 4 groups where both have models
  • AURUS
  • SLIMAIR TECHNOLOGIES
  • All models of the group
Ducted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeAURUSSLIMAIR TECHNOLOGIES
Ducted, 2 tons1 · index 48%None
Ducted, 2.5 to 3 tons1 · index 63%1 · index —
Ducted, 3.5 to 4.5 tons2 · index 51%1 · index —
Non-ducted, up to 1.5 tons6 · index 20%6 · index 30%
Non-ducted, 2 tons2 · index 26%2 · index 27%
Non-ducted, 2.5 to 3 tonsNone2 · index 18%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeAURUSCold-climate score, best modelSLIMAIR TECHNOLOGIESCold-climate score, best model
Ducted, 2 tons62.1(50 is the typical model of its size class)ARU-H24CD/INVS-USwith ducted air handler ARU-H24AH/INVS-US1 of 1 models qualify · AHRI 208842390No models in this size class
Ducted, 2.5 to 3 tons75.2(50 is the typical model of its size class)ARU-H36CD/INVS-USwith ducted air handler ARU-H36AH/INVS-US1 of 1 models qualify · AHRI 208842391None on this board (0 of 1 models qualify)
Ducted, 3.5 to 4.5 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons30.5(50 is the typical model of its size class)ARU-H12A1/INVL-US2with ductless indoor unit ARU-H12A1/INVL-US2Also listed as ARU-H12A2/INVL-US22 of 6 models qualify · AHRI 21061010336.3(50 is the typical model of its size class) (higher)SHC12VB-2Hwith ductless indoor unit SHM12VB-2DC1 of 6 models qualify · AHRI 9060039
Non-ducted, 2 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 2 models qualify)
Non-ducted, 2.5 to 3 tonsNo models in this size classNone on this board (0 of 2 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeAURUSAll-around score, best modelSLIMAIR TECHNOLOGIESAll-around score, best model
Ducted, 2 tons48.4(50 is the typical model of its size class)ARU-H24CD/INVS-USwith ducted air handler ARU-H24AH/INVS-US1 of 1 models have all five ratings · AHRI 208842390No models in this size class
Ducted, 2.5 to 3 tons63.1(50 is the typical model of its size class)ARU-H36CD/INVS-USwith ducted air handler ARU-H36AH/INVS-US1 of 1 models have all five ratings · AHRI 208842391None on this board (0 of 1 models have all five ratings)
Ducted, 3.5 to 4.5 tons57.1(50 is the typical model of its size class)ARU-H48CD/INVS-USwith ducted air handler ARU-H48AH/INVS-US2 of 2 models have all five ratings · AHRI 208842392None on this board (0 of 1 models have all five ratings)
Non-ducted, up to 1.5 tons24.8(50 is the typical model of its size class)ARU-H12A1/INVL-US2with ductless indoor unit ARU-H12A1/INVL-US2Also listed as ARU-H12A2/INVL-US24 of 6 models have all five ratings · AHRI 21061010347.8(50 is the typical model of its size class) (higher)SHC18VB-2Hwith ductless indoor unit SHM18VB-2DC6 of 6 models have all five ratings · AHRI 9060040
Non-ducted, 2 tons26.1(50 is the typical model of its size class)ARU-H24A2/INVL-US2with ductless indoor unit ARU-H24A2/INVL-US21 of 2 models have all five ratings · AHRI 21061010640.8(50 is the typical model of its size class) (higher)SHC24VB-2Hwith ductless indoor unit SHM24VB-2DC2 of 2 models have all five ratings · AHRI 9060043
Non-ducted, 2.5 to 3 tonsNo models in this size class29.7(50 is the typical model of its size class)SHC30VA-2Hwith ductless indoor unit SHM30VA-2VT2 of 2 models have all five ratings · AHRI 9060044

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingAURUSSLIMAIR TECHNOLOGIES
COP at 5°Fbeats 75% · 2.05ARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 26% · 1.80SHC18VB-2HNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 64% · 76%ARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 41% · 70%SHC12VB-2HNon-ducted, up to 1.5 tons
HSPF2beats 83% · 9.5ARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 81% · 9.3SHCD48VB2Ducted, 3.5 to 4.5 tons
SEER2beats 82% · 17.5ARU-H48CD/INVS-USDucted, 3.5 to 4.5 tonsbeats 67% · 22.5SHC18VB-2HNon-ducted, up to 1.5 tons
EER2beats 29% · 10.1ARU-H48CD/INVS-USDucted, 3.5 to 4.5 tonsbeats 80% · 13.7SHC09VB-2HNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 64% · 26,000 Btu/hARU-H36CD/INVS-USDucted, 2.5 to 3 tonsbeats 67% · 11,900 Btu/hSHC18VB-2HNon-ducted, up to 1.5 tons

More comparisons