Both views use the same certified data. This device remembers your choice.
Bestcold vs THERMAL ZONE heat pumps
Measured against models of the same size and duct type, THERMAL ZONE scores higher on 5 of the 6 ratings. Bestcold has 7 outdoor models, THERMAL ZONE has 88 outdoor models. Bestcold and THERMAL ZONE have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Bestcold
- THERMAL ZONE
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Bestcold | THERMAL ZONE |
|---|---|---|
| Efficiency index | 23%median — | 42%median — |
| COP at 5°F | 23%median 1.80 | 69%median 2.10 |
| Capacity retention at 5°F | 32%median 70% | 37%median 56% |
| HSPF2 | 19%median 8.5 | 31%median 7.5 |
| SEER2 | 27% (higher)median 19.0 | 26% (higher)median 14.3 |
| EER2 | 16%median 10.0 | 36%median 10.6 |
| Heating capacity at 5°F | 34%median 8,600 Btu/h | 40%median 19,750 Btu/h |
| Outdoor models | 7 | 88 |
| AHRI certifications | 7 | 509 |
Share of models meeting each standard
| Standard | Bestcold | THERMAL ZONE |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 71.4%5 models | 12.5%11 models |
| CEE 2026 Tier 1 (Split ASHP) | 57.1%4 models | 11.4%10 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 57.1%4 models | 6.8%6 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 21.6%19 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Bestcold
- THERMAL ZONE
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Bestcold | THERMAL ZONE |
|---|---|---|
| Ducted, up to 1.5 tons | None | 8 · index 31% |
| Ducted, 2 tons | None | 9 · index 42% |
| Ducted, 2.5 to 3 tons | None | 27 · index 44% |
| Ducted, 3.5 to 4.5 tons | None | 31 · index 46% |
| Ducted, 5 tons and up | None | 12 · index 55% |
| Non-ducted, up to 1.5 tons | 5 · index 22% | None |
| Non-ducted, 2 tons | 1 · index 26% | None |
| Non-ducted, 2.5 to 3 tons | 1 · index 25% | 1 · index — |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BestcoldCold-climate score, best model | THERMAL ZONECold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 67.9(50 is the typical model of its size class)TZPLV182PAwith ducted air handler H,RG21924+TD1 of 8 models qualify · AHRI 214311494 |
| Ducted, 2 tons | No models in this size class | 66.9(50 is the typical model of its size class)TZPLV242PAwith ducted air handler TZHVLE2417JA2 of 9 models qualify · AHRI 211126503 |
| Ducted, 2.5 to 3 tons | No models in this size class | 78.7(50 is the typical model of its size class)TZPLV362PAwith ducted air handler MAC-36HWDN1-MN02 of 27 models qualify · AHRI 213885869 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 74.0(50 is the typical model of its size class)TZPLV482PAwith ducted air handler TZHVLE4821JA2 of 31 models qualify · AHRI 211126512 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 12 models qualify) |
| Non-ducted, up to 1.5 tons | 30.5(50 is the typical model of its size class)MYTW-12HPAC1/Owith ductless indoor unit MYTW-12HPAC1/IAlso listed as MYTW-12HPAC2/O4 of 5 models qualify · AHRI 214844424 | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | No models in this size class |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | BestcoldAll-around score, best model | THERMAL ZONEAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 63.8(50 is the typical model of its size class)TZPLV182PAwith ducted air handler TZHVLE1817JA7 of 8 models have all five ratings · AHRI 211126509 |
| Ducted, 2 tons | No models in this size class | 66.0(50 is the typical model of its size class)TZPLV242PAwith ducted air handler TZHVLE2417JA6 of 9 models have all five ratings · AHRI 211126503 |
| Ducted, 2.5 to 3 tons | No models in this size class | 58.1(50 is the typical model of its size class)TZPLAD1530AJNwith ducted air handler TZHDLVST3617*NAN10 of 27 models have all five ratings · AHRI 212508013 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 62.3(50 is the typical model of its size class)TZPLAD1548AJNwith ducted air handler TZHDLVST4821*NAN10 of 30 models have all five ratings · AHRI 212508016 |
| Ducted, 5 tons and up | No models in this size class | 67.8(50 is the typical model of its size class)TZP15AZ60AJ2Nwith ducted air handler TZHDLTST6024*NANAlso listed as TZPLAD1560AJN3 of 13 models have all five ratings · AHRI 211641701 |
| Non-ducted, up to 1.5 tons | 24.8(50 is the typical model of its size class)MYTW-12HPAC1/Owith ductless indoor unit MYTW-12HPAC1/IAlso listed as MYTW-12HPAC2/O5 of 5 models have all five ratings · AHRI 214844424 | No models in this size class |
| Non-ducted, 2 tons | 26.1(50 is the typical model of its size class)MYTW-24HPAC2/Owith ductless indoor unit MYTW-24HPAC2/I1 of 1 models have all five ratings · AHRI 214844428 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 24.9(50 is the typical model of its size class)MYTW-36HPAC2/Owith ductless indoor unit MYTW-36HPAC2/I1 of 1 models have all five ratings · AHRI 214844429 | None on this board (0 of 1 models have all five ratings) |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Bestcold | THERMAL ZONE |
|---|---|---|
| COP at 5°F | beats 31% · 1.80MYTW-24HPAC2/ONon-ducted, 2 tons | beats 90% · 2.50TZPLAD1560AJNDucted, 3.5 to 4.5 tons |
| Capacity retention at 5°F | beats 48% · 70%MYTW-12HPAC1/OAlso listed as MYTW-12HPAC2/ONon-ducted, up to 1.5 tons | beats 97% · 102%TZPLV362PADucted, 2.5 to 3 tons |
| HSPF2 | beats 26% · 8.5MYTW-36HPAC2/ONon-ducted, 2.5 to 3 tons | beats 93% · 10.0TZPLV362PADucted, 2.5 to 3 tons |
| SEER2 | beats 36% · 19.0MYTW-24HPAC2/ONon-ducted, 2 tons | beats 70% · 16.0TZP15AZ60AJ2NAlso listed as TZPLAD1560AJNDucted, 5 tons and up |
| EER2 | beats 24% · 10.0MYTW-24HPAC2/ONon-ducted, 2 tons | beats 79% · 11.7TZP15AZ60AJ2NAlso listed as TZPLAD1560AJNDucted, 5 tons and up |
| Heating capacity at 5°F | beats 62% · 11,600 Btu/hMYTW-18HPAC2/ONon-ducted, up to 1.5 tons | beats 95% · 36,876 Btu/hTZPLV362PADucted, 2.5 to 3 tons |