Skip to content

BHI vs Econas heat pumps

Measured against models of the same size and duct type, Econas scores higher on 6 of the 6 ratings. BHI has 6 outdoor models, Econas has 6 outdoor models. BHI and Econas have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BHI and Econas on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Econas scores higher on 6 of the 6 ratings.
  • BHI
  • Econas
  • Other ranked manufacturers
BHIEconas

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBHIEconas
Efficiency index33%median —48%median —
COP at 5°F24%median 1.8040%median 1.83
Capacity retention at 5°F40%median 70%75%median 82%
HSPF217%median 8.381%median 9.5
SEER227%median 19.039%median 15.2
EER217%median 9.522%median 10.0
Heating capacity at 5°F40%median 8,700 Btu/h80%median 36,000 Btu/h
Outdoor models66
AHRI certifications69

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBHIEconas
CEE 2025 Tier 1 (Split ASHP)33.3%2 models16.7%1 models
CEE 2026 Tier 1 (Split ASHP)33.3%2 models16.7%1 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)33.3%2 models66.7%4 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate16.7%1 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 0 groups where both have models
  • BHI
  • Econas
  • All models of the group
Ducted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBHIEconas
Ducted, 2 tonsNone1 · index 53%
Ducted, 2.5 to 3 tonsNone2 · index 53%
Ducted, 3.5 to 4.5 tonsNone3 · index 42%
Non-ducted, up to 1.5 tons4 · index 37%None
Non-ducted, 2 tons1 · index —None
Non-ducted, 2.5 to 3 tons1 · index 25%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBHICold-climate score, best modelEconasCold-climate score, best model
Ducted, 2 tonsNo models in this size class65.9(50 is the typical model of its size class)EOD30-24HFN1-MWwith ducted air handler EVBM-24A18T3N11 of 1 models qualify · AHRI 214296068
Ducted, 2.5 to 3 tonsNo models in this size class78.7(50 is the typical model of its size class)EOE31U-36HFN1-Mwith ducted air handler EAC-36HWDN1-MN02 of 2 models qualify · AHRI 214296073
Ducted, 3.5 to 4.5 tonsNo models in this size class61.6(50 is the typical model of its size class)EOE30U-45HFN1-Mwith ducted air handler EAC-60HWDN1-MN03 of 3 models qualify · AHRI 214296075
Non-ducted, up to 1.5 tons41.3(50 is the typical model of its size class)BHI-12K115V-ES-USwith ductless indoor unit BHI-12K115V-ES-US2 of 4 models qualify · AHRI 212608423No models in this size class
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)No models in this size class
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 1 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBHIAll-around score, best modelEconasAll-around score, best model
Ducted, 2 tonsNo models in this size class53.2(50 is the typical model of its size class)EOD30-24HFN1-MWwith ducted air handler EVBM-24A18T3N11 of 1 models have all five ratings · AHRI 214296068
Ducted, 2.5 to 3 tonsNo models in this size class52.9(50 is the typical model of its size class)EOE31U-36HFN1-Mwith ducted air handler EAC-36HWDN1-MN02 of 2 models have all five ratings · AHRI 214296073
Ducted, 3.5 to 4.5 tonsNo models in this size class49.9(50 is the typical model of its size class)EOE30U-45HFN1-Mwith ducted air handler EAC-60HWDN1-MN03 of 3 models have all five ratings · AHRI 214296075
Non-ducted, up to 1.5 tons49.1(50 is the typical model of its size class)BHI-12K115V-ES-USwith ductless indoor unit BHI-12K115V-ES-US2 of 4 models have all five ratings · AHRI 212608423No models in this size class
Non-ducted, 2 tonsNone on this board (0 of 1 models have all five ratings)No models in this size class
Non-ducted, 2.5 to 3 tons24.9(50 is the typical model of its size class)BHI-T19-36K230V-USwith ductless indoor unit BHI-T19-36K230V-US1 of 1 models have all five ratings · AHRI 214797818No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBHIEconas
COP at 5°Fbeats 26% · 1.80BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 68% · 2.00EOE31U-36HFN1-MDucted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 56% · 73%BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 79% · 85%EOE30U-45HFN1-MDucted, 3.5 to 4.5 tons
HSPF2beats 40% · 9.0BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 93% · 10.0EOE31U-36HFN1-MDucted, 2.5 to 3 tons
SEER2beats 62% · 22.0BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 47% · 16.5EOD30-24HFN1-MWDucted, 2 tons
EER2beats 49% · 12.5BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 27% · 10.0EOE30U-45HFN1-MDucted, 3.5 to 4.5 tons
Heating capacity at 5°Fbeats 45% · 8,700 Btu/hBHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 89% · 46,500 Btu/hEOE30U-45HFN1-MDucted, 3.5 to 4.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter