Skip to content

BHI vs hykolity heat pumps

Measured against models of the same size and duct type, BHI and hykolity split the 6 ratings 3 to 3. BHI has 6 outdoor models, hykolity has 6 outdoor models. BHI and hykolity have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BHI and hykolity on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BHI and hykolity split the 6 ratings 3 to 3.
  • BHI
  • hykolity
  • Other ranked manufacturers
BHIhykolity

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBHIhykolity
Efficiency index33% (higher)median —24% (higher)median —
COP at 5°F24% (higher)median 1.8023% (higher)median 1.80
Capacity retention at 5°F40% (higher)median 70%26% (higher)median 63%
HSPF217%median 8.319%median 8.5
SEER227%median 19.030%median 19.0
EER217%median 9.523%median 10.0
Heating capacity at 5°F40% (higher)median 8,700 Btu/h37% (higher)median 12,300 Btu/h
Outdoor models66
AHRI certifications66

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBHIhykolity
CEE 2025 Tier 1 (Split ASHP)33.3%2 models66.7%4 models
CEE 2026 Tier 1 (Split ASHP)33.3%2 models50%3 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)33.3%2 models33.3%2 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate16.7%1 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 3 groups where both have models
  • BHI
  • hykolity
  • All models of the group
Non-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBHIhykolity
Non-ducted, up to 1.5 tons4 · index 37%4 · index 23%
Non-ducted, 2 tons1 · index —1 · index 26%
Non-ducted, 2.5 to 3 tons1 · index 25%1 · index 30%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBHICold-climate score, best modelhykolityCold-climate score, best model
Non-ducted, up to 1.5 tons41.3(50 is the typical model of its size class) (higher)BHI-12K115V-ES-USwith ductless indoor unit BHI-12K115V-ES-US2 of 4 models qualify · AHRI 21260842330.5(50 is the typical model of its size class)ACA-2504with ductless indoor unit ACA-25032 of 4 models qualify · AHRI 214584768
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBHIAll-around score, best modelhykolityAll-around score, best model
Non-ducted, up to 1.5 tons49.1(50 is the typical model of its size class) (higher)BHI-12K115V-ES-USwith ductless indoor unit BHI-12K115V-ES-US2 of 4 models have all five ratings · AHRI 21260842328.2(50 is the typical model of its size class)ACA-25314 of 4 models have all five ratings · AHRI 217497281
Non-ducted, 2 tonsNone on this board (0 of 1 models have all five ratings)26.1(50 is the typical model of its size class)ACA-2512with ductless indoor unit ACA-25111 of 1 models have all five ratings · AHRI 217497283
Non-ducted, 2.5 to 3 tons24.9(50 is the typical model of its size class)BHI-T19-36K230V-USwith ductless indoor unit BHI-T19-36K230V-US1 of 1 models have all five ratings · AHRI 21479781829.6(50 is the typical model of its size class) (higher)ACA-25331 of 1 models have all five ratings · AHRI 217497282

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBHIhykolity
COP at 5°Fbeats 26% · 1.80BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 31% · 1.80ACA-2512Non-ducted, 2 tons
Capacity retention at 5°Fbeats 56% · 73%BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 48% · 70%ACA-2504Non-ducted, up to 1.5 tons
HSPF2beats 40% · 9.0BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 26% · 8.5ACA-2533Non-ducted, 2.5 to 3 tons
SEER2beats 62% · 22.0BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 36% · 19.0ACA-2512Non-ducted, 2 tons
EER2beats 49% · 12.5BHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 39% · 10.0ACA-2533Non-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 45% · 8,700 Btu/hBHI-12K115V-ES-USNon-ducted, up to 1.5 tonsbeats 79% · 13,000 Btu/hACA-2531Non-ducted, up to 1.5 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter