Measured against models of the same size and duct type, Bladex and YONAN split the 6 ratings 3 to 3. Bladex has 56 outdoor models, YONAN has 55 outdoor models. Bladex and YONAN have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Bladex and YONAN on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Bladex and YONAN split the 6 ratings 3 to 3.
  • Bladex
  • YONAN
  • Other ranked manufacturers
BladexYONAN

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBladexYONAN
Efficiency index57% (higher)median —55% (higher)median —
COP at 5°F46%median 1.9055%median 2.00
Capacity retention at 5°F62% (higher)median 79%37% (higher)median 66%
HSPF268% (higher)median 9.561% (higher)median 9.5
SEER260%median 20.061%median 21.1
EER249%median 10.751%median 12.2
Heating capacity at 5°F62% (higher)median 22,000 Btu/h40% (higher)median 12,600 Btu/h
Outdoor models5655
AHRI certifications14188

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBladexYONAN
CEE 2025 Tier 1 (Split ASHP)66.1%37 models67.3%37 models
CEE 2026 Tier 1 (Split ASHP)62.5%35 models58.2%32 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)57.1%32 models34.5%19 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Bladex
  • YONAN
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBladexYONAN
Ducted, up to 1.5 tons5 · index 51%5 · index 67%
Ducted, 2 tons2 · index 50%2 · index 79%
Ducted, 2.5 to 3 tons17 · index 62%5 · index 59%
Ducted, 3.5 to 4.5 tons12 · index 57%4 · index 56%
Ducted, 5 tons and upNone1 · index 57%
Non-ducted, up to 1.5 tons17 · index 48%30 · index 56%
Non-ducted, 2 tons3 · index 42%8 · index 52%
Non-ducted, 2.5 to 3 tons13 · index 67%11 · index 48%
Non-ducted, 3.5 to 4.5 tons6 · index 56%6 · index 43%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBladexCold-climate score, best modelYONANCold-climate score, best model
Ducted, up to 1.5 tons64.2(50 is the typical model of its size class)BX30U-18HPHYHAwith ducted air handler BLC-24HWAC14 of 5 models qualify · AHRI 21236743271.0(50 is the typical model of its size class) (higher)YOX-09HFN1with ducted air handler YTI-09HWFN14 of 5 models qualify · AHRI 208106973
Ducted, 2 tons67.6(50 is the typical model of its size class)BX24-HP15ECOwith ducted air handler BLC-24HWAC12 of 2 models qualify · AHRI 21252800480.6(50 is the typical model of its size class) (higher)YOD-24HFN1with ducted air handler YTI-24HWFN12 of 2 models qualify · AHRI 208106980
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class) (higher)B30K-27SPHP1Also listed as B30K-27SPHP113 of 17 models qualify · AHRI 21292065257.6(50 is the typical model of its size class)YSMO-30HRN1Also listed as YSMO-27HFN12 of 5 models qualify · AHRI 207691834
Ducted, 3.5 to 4.5 tons82.2(50 is the typical model of its size class)BCUC30-55ODU2024GA-Xwith ducted air handler BDI-60HWFN17 of 12 models qualify · AHRI 214377796None on this board (0 of 4 models qualify)
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)BS25-06HFN1-ODUwith ductless indoor unit BWM-EPB-06HWIU8 of 17 models qualify · AHRI 21431255086.6(50 is the typical model of its size class)YSA25-09HRN1with ductless indoor unit YSA25-09HRN1Also listed as YS-09HRFN1-C5OU9 of 30 models qualify · AHRI 207671408
Non-ducted, 2 tons85.5(50 is the typical model of its size class) (higher)BS25-24HFN1-ODUwith ductless indoor unit BWM-EPB-24HWIU1 of 3 models qualify · AHRI 21431255475.6(50 is the typical model of its size class)YOD-24HFN1with ductless indoor unit YUE-24HRFN14 of 8 models qualify · AHRI 208106981
Non-ducted, 2.5 to 3 tons91.3(50 is the typical model of its size class) (higher)B40X-36SPHP1S*10 of 13 models qualify · AHRI 21423242351.5(50 is the typical model of its size class)YSMO-30HRN1Also listed as YSMO-27HFN12 of 11 models qualify · AHRI 207691833
Non-ducted, 3.5 to 4.5 tons80.7(50 is the typical model of its size class) (higher)B50G-48SPHP14 of 6 models qualify · AHRI 21292065656.2(50 is the typical model of its size class)YOE-48HFN1with ductless indoor unit YUE-48HRFN11 of 6 models qualify · AHRI 208106987

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBladexAll-around score, best modelYONANAll-around score, best model
Ducted, up to 1.5 tons63.8(50 is the typical model of its size class)BX30U-18HPHYHAwith ducted air handler BLA-18HWAHU15 of 5 models have all five ratings · AHRI 21236743778.8(50 is the typical model of its size class) (higher)YOX-18HFN1with ducted air handler YTI-18HWFN15 of 5 models have all five ratings · AHRI 208106977
Ducted, 2 tons66.0(50 is the typical model of its size class)BX30-24HPHYHAwith ducted air handler BLA-24HWAHU12 of 2 models have all five ratings · AHRI 21236743884.0(50 is the typical model of its size class) (higher)YOD-24HFN1with ducted air handler YTI-24HWFN12 of 2 models have all five ratings · AHRI 208106980
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class) (higher)B40XS-36SPHP1Also listed as B40X-36SPHP1S17 of 17 models have all five ratings · AHRI 21330789471.7(50 is the typical model of its size class)YSMO-30HRN1Also listed as YSMO-27HFN15 of 5 models have all five ratings · AHRI 207691834
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)B50G-48SPHP1Also listed as B50G-48SPHP112 of 12 models have all five ratings · AHRI 21292065763.5(50 is the typical model of its size class)YSMO-48HRN1Also listed as YSMO-48HFN14 of 4 models have all five ratings · AHRI 207691831
Ducted, 5 tons and upNo models in this size class57.2(50 is the typical model of its size class)YOE-60HFN1with ducted air handler YHG-60HWFN11 of 1 models have all five ratings · AHRI 208106988
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)BS25-06HFN1-ODUwith ductless indoor unit BWM-EPB-06HWIU17 of 17 models have all five ratings · AHRI 21431255088.8(50 is the typical model of its size class)YSA25-09HRN1with ductless indoor unit YSA25-09HRN1Also listed as YS-09HRFN1-C5OU30 of 30 models have all five ratings · AHRI 207671408
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)BS25-24HFN1-ODUwith ductless indoor unit BWM-EPB-24HWIU3 of 3 models have all five ratings · AHRI 21431255478.6(50 is the typical model of its size class)YSA25-24HRN1with ductless indoor unit YSA25-24HRN1Also listed as YS-24HRFN1-C5OU8 of 8 models have all five ratings · AHRI 207671411
Non-ducted, 2.5 to 3 tons86.7(50 is the typical model of its size class) (higher)B40X-36SPHP1S*13 of 13 models have all five ratings · AHRI 21423242368.0(50 is the typical model of its size class)YSMO-30HRN1Also listed as YSMO-27HFN18 of 11 models have all five ratings · AHRI 207691833
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)B50G-48SPHP1*6 of 6 models have all five ratings · AHRI 21423242648.3(50 is the typical model of its size class)YSMO-48HRN1Also listed as YSMO-48HFN15 of 6 models have all five ratings · AHRI 207691830

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBladexYONAN
COP at 5°Fbeats 92% · 2.21BS25-24HFN1-ODUNon-ducted, 2 tonsbeats 97% · 2.39YSA25-12HRN1Also listed as YS-12HRFN1-C5OUNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 103%B30K-27SPHP1*Non-ducted, 2.5 to 3 tonsbeats 96% · 114%YS-09HRFN1-E0OUNon-ducted, up to 1.5 tons
HSPF2beats 99% · 13.6BS25-06HFN1-ODUNon-ducted, up to 1.5 tonsbeats 98% · 11.2YOD-24HFN1Ducted, 2 tons
SEER2beats 99% · 20.9B50G-48SPHP1Also listed as B50G-48SPHP1Ducted, 3.5 to 4.5 tonsbeats 99% · 28.5YS-09HRFN1-E0OUNon-ducted, up to 1.5 tons
EER2beats 98% · 16.2BS25-09HFN1-ODUNon-ducted, up to 1.5 tonsbeats 97% · 16.0YS-09HRFN1-E0OUNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 98% · 53,000 Btu/hBCUC30-55ODU2024GA-XDucted, 3.5 to 4.5 tonsbeats 83% · 13,700 Btu/hYS-09HRFN1-E0OUNon-ducted, up to 1.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Bladex vs YONAN: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Bladex (median, middle 50%)
  • YONAN (median, middle 50%)
Heating capacity, % of its 47°F maximum69%59%COP at maximum capacity1.902.00

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
Bladex: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Bladex, 47°F48100%100%100%100%100%
Bladex, 17°F4865%70%76%79%85%
Bladex, 5°F4854%57%69%79%82%
Bladex: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Bladex, 47°F482.692.863.093.23.36
Bladex, 17°F481.92.052.192.232.31
Bladex, 5°F481.81.811.922.08
YONAN: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
YONAN, 47°F41100%100%100%100%100%
YONAN, 17°F4165%67%71%74%75%
YONAN, 5°F4153%55%59%63%65%
YONAN: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
YONAN, 47°F412.642.913.153.443.56
YONAN, 17°F412.022.112.232.372.41
YONAN, 5°F411.81.8522.092.3

Source: NEEP ccASHP list · as of