Both views use the same certified data. This device remembers your choice.
Bluefin vs iFLOW heat pumps
Measured against models of the same size and duct type, Bluefin and iFLOW split the 6 ratings 3 to 3. Bluefin has 14 outdoor models, iFLOW has 14 outdoor models. Bluefin and iFLOW have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Bluefin
- iFLOW
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Bluefin | iFLOW |
|---|---|---|
| Efficiency index | 61% (higher)median — | 43% (higher)median — |
| COP at 5°F | 64% (higher)median 1.95 | 44% (higher)median 1.88 |
| Capacity retention at 5°F | 52%median 72% | 58%median 79% |
| HSPF2 | 60%median 9.9 | 70%median 9.1 |
| SEER2 | 65% (higher)median 21.9 | 36% (higher)median 15.2 |
| EER2 | 63% (higher)median 12.8 | 21% (higher)median 10.0 |
| Heating capacity at 5°F | 49%median 12,265 Btu/h | 63%median 29,000 Btu/h |
| Outdoor models | 14 | 14 |
| AHRI certifications | 14 | 19 |
Share of models meeting each standard
| Standard | Bluefin | iFLOW |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 85.7%12 models | 14.3%2 models |
| CEE 2026 Tier 1 (Split ASHP) | 85.7%12 models | 14.3%2 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 64.3%9 models | 50%7 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 57.1%8 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Bluefin
- iFLOW
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Bluefin | iFLOW |
|---|---|---|
| Ducted, up to 1.5 tons | None | 1 · index 52% |
| Ducted, 2 tons | None | 2 · index 50% |
| Ducted, 2.5 to 3 tons | None | 5 · index 43% |
| Ducted, 3.5 to 4.5 tons | None | 6 · index 39% |
| Non-ducted, up to 1.5 tons | 9 · index 67% | None |
| Non-ducted, 2 tons | 3 · index 56% | None |
| Non-ducted, 2.5 to 3 tons | 2 · index 45% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BluefinCold-climate score, best model | iFLOWCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 64.2(50 is the typical model of its size class)70HPIC18Awith ducted air handler 70C1824BA1 of 1 models qualify · AHRI 212546248 |
| Ducted, 2 tons | No models in this size class | 67.6(50 is the typical model of its size class)70HPIR24Awith ducted air handler 70C1824BA2 of 2 models qualify · AHRI 217729802 |
| Ducted, 2.5 to 3 tons | No models in this size class | 78.7(50 is the typical model of its size class)70HPIC36Awith ducted air handler 70C3036CA3 of 5 models qualify · AHRI 212546252 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 61.6(50 is the typical model of its size class)70HPIC45Awith ducted air handler 70C5460DA3 of 6 models qualify · AHRI 213279880 |
| Non-ducted, up to 1.5 tons | 86.6(50 is the typical model of its size class)BFMS09PL-01Owith ductless indoor unit BFMS09PL-01I7 of 9 models qualify · AHRI 213769908 | No models in this size class |
| Non-ducted, 2 tons | 63.4(50 is the typical model of its size class)BFMS24PR-01Owith ductless indoor unit BFMS24PL-01I2 of 3 models qualify · AHRI 213769902 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | None on this board (0 of 2 models qualify) | No models in this size class |
All-around best
| Size and duct type | BluefinAll-around score, best model | iFLOWAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | No models in this size class | 51.9(50 is the typical model of its size class)70HPIC18Awith ducted air handler 70C1824BA1 of 1 models have all five ratings · AHRI 212546248 |
| Ducted, 2 tons | No models in this size class | 53.2(50 is the typical model of its size class)70HPIC24Awith ducted air handler 70C1824AA2 of 2 models have all five ratings · AHRI 218029482 |
| Ducted, 2.5 to 3 tons | No models in this size class | 52.9(50 is the typical model of its size class)70HPIC36Awith ducted air handler 70C3036CA5 of 5 models have all five ratings · AHRI 212546252 |
| Ducted, 3.5 to 4.5 tons | No models in this size class | 49.9(50 is the typical model of its size class)70HPIC45Awith ducted air handler 70C5460DA6 of 6 models have all five ratings · AHRI 213279880 |
| Non-ducted, up to 1.5 tons | 87.1(50 is the typical model of its size class)BFMS09PL-01Owith ductless indoor unit BFMS09PL-01I9 of 9 models have all five ratings · AHRI 213769908 | No models in this size class |
| Non-ducted, 2 tons | 71.9(50 is the typical model of its size class)BFMS24PR-01Owith ductless indoor unit BFMS24PL-01I3 of 3 models have all five ratings · AHRI 213769902 | No models in this size class |
| Non-ducted, 2.5 to 3 tons | 54.4(50 is the typical model of its size class)BFMS30BA-01Owith ductless indoor unit BFMS30BA-01I2 of 2 models have all five ratings · AHRI 213769903 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Bluefin | iFLOW |
|---|---|---|
| COP at 5°F | beats 97% · 2.22BFMS24PL-01ONon-ducted, 2 tons | beats 76% · 2.2070HPIC18ADucted, up to 1.5 tons |
| Capacity retention at 5°F | beats 77% · 96%BFMS18PR-01ONon-ducted, up to 1.5 tons | beats 79% · 85%70HPIC45ADucted, 3.5 to 4.5 tons |
| HSPF2 | beats 94% · 11.6BFMS09PL-01ONon-ducted, up to 1.5 tons | beats 93% · 10.070HPIC36ADucted, 2.5 to 3 tons |
| SEER2 | beats 92% · 26.4BFMS09PR-01ONon-ducted, up to 1.5 tons | beats 47% · 16.570HPIC24ADucted, 2 tons |
| EER2 | beats 95% · 15.8BFMS09PR-01ONon-ducted, up to 1.5 tons | beats 36% · 11.770HPIC18ADucted, up to 1.5 tons |
| Heating capacity at 5°F | beats 90% · 17,200 Btu/hBFMS18PR-01ONon-ducted, up to 1.5 tons | beats 89% · 46,500 Btu/h70HPIC45ADucted, 3.5 to 4.5 tons |