Skip to content

BlueRidge vs Midea heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings. BlueRidge has 83 outdoor models, Midea has 408 outdoor models. They share hardware: 56 equipment families appear under both names.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and Midea on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 4 of the 6 ratings.
  • BlueRidge
  • Midea
  • Other ranked manufacturers
BlueRidgeMidea

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeMidea
Efficiency index54%median — · 13th ranked55%median — · 12th ranked
COP at 5°F53% (higher)median 1.95 · 16th ranked49% (higher)median 1.93 · 19th ranked
Capacity retention at 5°F57% (higher)median 70% · 11th ranked52% (higher)median 69% · 16th ranked
HSPF256%median 9.1 · 10th ranked63%median 9.2 · 9th ranked
SEER250%median 18.9 · 13th ranked58%median 19.0 · 9th ranked
EER249% (higher)median 11.0 · 16th ranked47% (higher)median 11.0 · 19th ranked
Heating capacity at 5°F57% (higher)median 20,000 Btu/h · 9th ranked53% (higher)median 20,000 Btu/h · 15th ranked
Outdoor models83408
AHRI certifications1,2451,554

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeMidea
CEE 2025 Tier 1 (Split ASHP)61.4%51 models60.3%246 models
CEE 2026 Tier 1 (Split ASHP)57.8%48 models57.4%234 models
CEE Advanced Tier (Split ASHP)1.2%1 models2.7%11 models
Xcel Energy Colorado cold-climate ASHP (2025)45.8%38 models45.1%184 models
DOE Cold Climate Heat Pump Challenge1.2%1 models2.7%11 models
ENERGY STAR Cold Climate43.4%36 models37.3%152 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • BlueRidge
  • Midea
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsNon-ducted, 5 tons and up2.0137 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeMidea
Ducted, up to 1.5 tons7 · index 52%48 · index 60%
Ducted, 2 tons5 · index 55%34 · index 59%
Ducted, 2.5 to 3 tons21 · index 59%100 · index 55%
Ducted, 3.5 to 4.5 tons12 · index 61%67 · index 56%
Ducted, 5 tons and up1 · index 63%21 · index 49%
Non-ducted, up to 1.5 tons25 · index 51%122 · index 54%
Non-ducted, 2 tons7 · index 55%31 · index 54%
Non-ducted, 2.5 to 3 tons18 · index 57%95 · index 55%
Non-ducted, 3.5 to 4.5 tons9 · index 42%50 · index 49%
Non-ducted, 5 tons and upNone1 · index 10%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelMideaCold-climate score, best model
Ducted, up to 1.5 tons65.8(50 is the typical model of its size class)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models qualify · AHRI 20757138787.0(50 is the typical model of its size class) (higher)MOX430U-18HFN1-Mwith ducted air handler MVBE-18HWFN1-MM3E41 of 49 models qualify · AHRI 213156951
Ducted, 2 tons79.6(50 is the typical model of its size class)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models qualify · AHRI 20757139380.6(50 is the typical model of its size class) (higher)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M30 of 33 models qualify · AHRI 206330133
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class)BMM27HH2C12 of 21 models qualify · AHRI 21236017984.7(50 is the typical model of its size class) (higher)MOE30U-32HFN1-M-[X]with ducted air handler MTI-32HWFN1-M49 of 101 models qualify · AHRI 205823026
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)BMM48HHC4 of 12 models qualify · AHRI 20764130186.5(50 is the typical model of its size class) (higher)MOE30U-48HFN1-M-[X]with ducted air handler MTI-48HWFN1-MAlso sold as CTMorley MOU-A48LH-2; also listed as MOE30U-48HFN1-M-[X](GA)34 of 66 models qualify · AHRI 204829821
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)70.2(50 is the typical model of its size class)MRB-60HWD1N1-M19Also listed as MRD-60HWD1N1-M182 of 21 models qualify · AHRI 202680577
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class)BMY6HH27Cwith ductless indoor unit BMY6HH27WM14 of 25 models qualify · AHRI 20782669292.7(50 is the typical model of its size class) (higher)MOX230-09HFN1-MY2Wwith ductless indoor unit MFA2U-09HRFN1-MY6W58 of 122 models qualify · AHRI 209248925
Non-ducted, 2 tons86.3(50 is the typical model of its size class)BMY24HH22Cwith ductless indoor unit BM24MFCC4 of 7 models qualify · AHRI 20757139487.1(50 is the typical model of its size class) (higher)38MARBQ24AA3with ductless indoor unit 40MBCAQ24XA3Also sold as MDV MOD30-24HFN1-MU0W, CTMorley MOU-A24H-2, MDV MOD30-24HFN1-MU0W-L; also listed as DLCSRBH24AAK18 of 31 models qualify · AHRI 207683320
Non-ducted, 2.5 to 3 tons87.5(50 is the typical model of its size class)BMM36HH2C10 of 18 models qualify · AHRI 21336337691.3(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X*31 of 95 models qualify · AHRI 213301877
Non-ducted, 3.5 to 4.5 tons80.7(50 is the typical model of its size class)BMM48HHC6 of 9 models qualify · AHRI 20764130087.6(50 is the typical model of its size class) (higher)M5OG-42HFN1-M-[X]with ductless indoor unit MSEPB-09HRFN1-MY5W(GA)29 of 50 models qualify · AHRI 207617657
Non-ducted, 5 tons and upNo models in this size classNone on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelMideaAll-around score, best model
Ducted, up to 1.5 tons64.7(50 is the typical model of its size class)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models have all five ratings · AHRI 20757138785.4(50 is the typical model of its size class) (higher)38MARBQ09AA3with ducted air handler 40MBDQ09---3Also sold as MDV MOX330-09HFN1-MY5W, CTMorley MOU-A09H-2; also listed as DLCSRBH09AAK51 of 51 models have all five ratings · AHRI 206350372
Ducted, 2 tons80.2(50 is the typical model of its size class)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models have all five ratings · AHRI 20757139384.0(50 is the typical model of its size class) (higher)MOD33-24HFN1-MT0Wwith ducted air handler MTIU-24HWFN1-M31 of 31 models have all five ratings · AHRI 206330133
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class)BMM36HH2C18 of 20 models have all five ratings · AHRI 21336337783.7(50 is the typical model of its size class)M4OX630-36HFN1-M1XAlso listed as M4OX630-36HFN1-M1X95 of 100 models have all five ratings · AHRI 213301875
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)BMM48HHC10 of 13 models have all five ratings · AHRI 20764130184.7(50 is the typical model of its size class) (higher)M5OG-42HFN1-M-[X]61 of 67 models have all five ratings · AHRI 207617659
Ducted, 5 tons and up62.8(50 is the typical model of its size class)BHP17L60P-**Awith indoor coil BC1P60C+TDR+TXV and furnace BG801UH090CE201 of 1 models have all five ratings · AHRI 21261986675.5(50 is the typical model of its size class) (higher)MRB-60HWD1N1-M19Also listed as MRD-60HWD1N1-M1820 of 21 models have all five ratings · AHRI 202680577
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class)BMY6HH27Cwith ductless indoor unit BMY6HH27WM25 of 25 models have all five ratings · AHRI 20782669292.7(50 is the typical model of its size class) (higher)MOX230-09HFN1-MW5W-Lwith ductless indoor unit MSEPB-06HRFN1-MY5W119 of 122 models have all five ratings · AHRI 213199198
Non-ducted, 2 tons84.9(50 is the typical model of its size class)BMY24HH22Cwith ductless indoor unit BMY24HH22WM7 of 7 models have all five ratings · AHRI 20733918684.9(50 is the typical model of its size class)38MARBQ24AA3with ductless indoor unit DHMAHBQ24XA3Also sold as MDV MOD30-24HFN1-MU0W, MDV MOD30-24HFN1-MU0W-L; also listed as DLCSRBH24AAK31 of 31 models have all five ratings · AHRI 206350321
Non-ducted, 2.5 to 3 tons79.3(50 is the typical model of its size class)BMM27HH2C16 of 18 models have all five ratings · AHRI 21236017886.7(50 is the typical model of its size class) (higher)M4OX630-36HFN1-M1X*85 of 95 models have all five ratings · AHRI 213301877
Non-ducted, 3.5 to 4.5 tons73.9(50 is the typical model of its size class)BMM48HHC9 of 9 models have all five ratings · AHRI 20764130085.9(50 is the typical model of its size class) (higher)M5OG-42HFN1-M-[X]with ductless indoor unit MSEPB-09HRFN1-MY5W(GA)47 of 50 models have all five ratings · AHRI 207617657
Non-ducted, 5 tons and upNo models in this size class10.0(50 is the typical model of its size class)MDV-V60WMN1T*1 of 1 models have all five ratings · AHRI 212604264

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeMidea
COP at 5°Fbeats 96% · 2.77BHP17L48P-**ADucted, 3.5 to 4.5 tonsbeats 98% · 2.45MOX230-09HFN1-MY2WNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 99% · 144%BMKH0938/ONon-ducted, up to 1.5 tonsbeats 99% · 137%MOX330-09HFN1-MY6WNon-ducted, up to 1.5 tons
HSPF2beats 99% · 11.0BMY36HHUCDucted, 2.5 to 3 tonsbeats 100% · 15.038MPRBQ09AA3Also sold as MDV MOX430-09HFN1-MZG5W; also listed as DLCPRBH09AAKNon-ducted, up to 1.5 tons
SEER2beats 99% · 20.9BMM48HHCDucted, 3.5 to 4.5 tonsbeats 100% · 26.038MGHBQ30DA3Also sold as MDV M4OG-30HFN1-M; also listed as MMCMHAQ30DA3Non-ducted, 2.5 to 3 tons
EER2beats 99% · 14.0BHP17L24P-**ADucted, 2 tonsbeats 99% · 16.5MOX430-09HFN1-MZG5WNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hBMY60HHUCNon-ducted, 3.5 to 4.5 tonsbeats 100% · 46,000 Btu/hMOE30U-32HFN1-M-[X]Ducted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
BlueRidge vs Midea: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • BlueRidge (median, middle 50%)
  • Midea (median, middle 50%)
Heating capacity, % of its 47°F maximum70%63%COP at maximum capacity1.921.97

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
BlueRidge: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F50100%100%100%100%100%
BlueRidge, 17°F5066%70%76%84%92%
BlueRidge, 5°F5054%57%70%77%83%
BlueRidge: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
BlueRidge, 47°F502.642.813.063.213.45
BlueRidge, 17°F501.982.12.232.312.41
BlueRidge, 5°F501.81.831.9222.09
Midea: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Midea, 47°F239100%100%100%100%100%
Midea, 17°F23964%67%72%79%84%
Midea, 5°F23955%57%63%73%82%
Midea: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Midea, 47°F2392.642.873.093.273.47
Midea, 17°F2391.92.052.22.32.45
Midea, 5°F2391.81.831.972.022.18

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy