Skip to content

BlueRidge vs THERMAL ZONE heat pumps

Measured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings. BlueRidge has 83 outdoor models, THERMAL ZONE has 88 outdoor models. THERMAL ZONE has no QMID on file and is not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
BlueRidge and THERMAL ZONE on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, BlueRidge scores higher on 5 of the 6 ratings.
  • BlueRidge
  • THERMAL ZONE
  • Other ranked manufacturers
BlueRidgeTHERMAL …

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingBlueRidgeTHERMAL ZONE
Efficiency index54% (higher)median — · 17th ranked43% (higher)median —
COP at 5°F51%median 1.95 · 16th ranked68%median 2.10
Capacity retention at 5°F57% (higher)median 70% · 11th ranked37% (higher)median 56%
HSPF255% (higher)median 9.1 · 10th ranked31% (higher)median 7.5
SEER250% (higher)median 18.9 · 14th ranked26% (higher)median 14.3
EER249% (higher)median 11.0 · 16th ranked36% (higher)median 10.6
Heating capacity at 5°F57% (higher)median 20,000 Btu/h · 9th ranked40% (higher)median 19,900 Btu/h
Outdoor models8388
AHRI certifications1,245509

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardBlueRidgeTHERMAL ZONE
CEE 2025 Tier 1 (Split ASHP)61.4%51 models12.5%11 models
CEE 2026 Tier 1 (Split ASHP)57.8%48 models11.4%10 models
CEE Advanced Tier (Split ASHP)2.4%2 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)45.8%38 models6.8%6 models
DOE Cold Climate Heat Pump Challenge2.4%2 models0%0 models
ENERGY STAR Cold Climate47%39 models21.6%19 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 6 groups where both have models
  • BlueRidge
  • THERMAL ZONE
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeBlueRidgeTHERMAL ZONE
Ducted, up to 1.5 tons7 · index 52%8 · index 32%
Ducted, 2 tons5 · index 54%9 · index 42%
Ducted, 2.5–3 tons21 · index 59%27 · index 44%
Ducted, 3.5–4.5 tons12 · index 61%31 · index 46%
Ducted, 5 tons and up1 · index 63%12 · index 55%
Non-ducted, up to 1.5 tons25 · index 50%None
Non-ducted, 2 tons7 · index 54%None
Non-ducted, 2.5–3 tons18 · index 56%1 · index —
Non-ducted, 3.5–4.5 tons9 · index 42%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeBlueRidgeCold-climate score, best modelTHERMAL ZONECold-climate score, best model
Ducted, up to 1.5 tons65.4(50 is the typical model of its size class)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models qualify · AHRI 20757138767.7(50 is the typical model of its size class) (higher)TZPLV182PAwith ducted air handler H,RG21924+TD1 of 8 models qualify · AHRI 214311494
Ducted, 2 tons79.4(50 is the typical model of its size class) (higher)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models qualify · AHRI 20757139366.5(50 is the typical model of its size class)TZPLV242PAwith ducted air handler TZHVLE2417JA2 of 9 models qualify · AHRI 211126503
Ducted, 2.5–3 tons80.4(50 is the typical model of its size class) (higher)BMM27HH2C12 of 21 models qualify · AHRI 21236017978.6(50 is the typical model of its size class)TZPLV362PAwith ducted air handler MAC-36HWDN1-MN02 of 27 models qualify · AHRI 213885869
Ducted, 3.5–4.5 tons74.9(50 is the typical model of its size class) (higher)BMM48HHC4 of 12 models qualify · AHRI 20764130173.8(50 is the typical model of its size class)TZPLV482PAwith ducted air handler TZHVLE4821JA2 of 31 models qualify · AHRI 211126512
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 12 models qualify)
Non-ducted, up to 1.5 tons89.3(50 is the typical model of its size class)BMY6HH27Cwith ductless indoor unit BMY6HH27WM14 of 25 models qualify · AHRI 207826692No models in this size class
Non-ducted, 2 tons85.4(50 is the typical model of its size class)BMY24HH22Cwith ductless indoor unit BM24MFCC4 of 7 models qualify · AHRI 207571394No models in this size class
Non-ducted, 2.5–3 tons87.0(50 is the typical model of its size class)BMM36HH2C10 of 18 models qualify · AHRI 213363376None on this board (0 of 1 models qualify)
Non-ducted, 3.5–4.5 tons80.5(50 is the typical model of its size class)BMM48HHC6 of 9 models qualify · AHRI 207641300No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeBlueRidgeAll-around score, best modelTHERMAL ZONEAll-around score, best model
Ducted, up to 1.5 tons64.5(50 is the typical model of its size class) (higher)BMY12HH26Cwith ducted air handler BM12MCD7 of 7 models have all five ratings · AHRI 20757138763.4(50 is the typical model of its size class)TZPLV182PAwith ducted air handler TZHVLE1817JA6 of 8 models have all five ratings · AHRI 211126509
Ducted, 2 tons80.1(50 is the typical model of its size class) (higher)BMY24HH22Cwith ducted air handler BM24MCD4 of 5 models have all five ratings · AHRI 20757139365.8(50 is the typical model of its size class)TZPLV242PAwith ducted air handler TZHVLE2417JA6 of 9 models have all five ratings · AHRI 211126503
Ducted, 2.5–3 tons83.7(50 is the typical model of its size class) (higher)BMM36HH2C18 of 20 models have all five ratings · AHRI 21336337758.0(50 is the typical model of its size class)TZPLAD1530AJNwith ducted air handler TZHDLVST3617*NAN10 of 27 models have all five ratings · AHRI 212508013
Ducted, 3.5–4.5 tons82.0(50 is the typical model of its size class) (higher)BMM48HHC10 of 13 models have all five ratings · AHRI 20764130162.1(50 is the typical model of its size class)TZPLAD1548AJNwith ducted air handler TZHDLVST4821*NAN10 of 30 models have all five ratings · AHRI 212508016
Ducted, 5 tons and up62.6(50 is the typical model of its size class)BHP17L60P-**Awith indoor coil BC1P60C+TDR+TXV and furnace BG801UH090CE201 of 1 models have all five ratings · AHRI 21261986667.6(50 is the typical model of its size class) (higher)TZP15AZ60AJ2Nwith ducted air handler TZHDLTST6024*NANAlso listed as TZPLAD1560AJN3 of 13 models have all five ratings · AHRI 211641701
Non-ducted, up to 1.5 tons92.0(50 is the typical model of its size class)BMY6HH27Cwith ductless indoor unit BMY6HH27WM25 of 25 models have all five ratings · AHRI 207826692No models in this size class
Non-ducted, 2 tons84.3(50 is the typical model of its size class)BMY24HH22Cwith ductless indoor unit BMY24HH22WM7 of 7 models have all five ratings · AHRI 207339186No models in this size class
Non-ducted, 2.5–3 tons78.8(50 is the typical model of its size class)BMM27HH2C16 of 18 models have all five ratings · AHRI 212360178None on this board (0 of 1 models have all five ratings)
Non-ducted, 3.5–4.5 tons73.8(50 is the typical model of its size class)BMM48HHC9 of 9 models have all five ratings · AHRI 207641300No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingBlueRidgeTHERMAL ZONE
COP at 5°Fbeats 96% · 2.77BHP17L48P-**ADucted, 3.5–4.5 tonsbeats 90% · 2.50TZPLAD1560AJNDucted, 3.5–4.5 tons
Capacity retention at 5°Fbeats 99% · 144%BMKH0938/ONon-ducted, up to 1.5 tonsbeats 97% · 102%TZPLV362PADucted, 2.5–3 tons
HSPF2beats 99% · 11.0BMY36HHUCDucted, 2.5–3 tonsbeats 93% · 10.0TZPLV362PADucted, 2.5–3 tons
SEER2beats 99% · 20.9BMM48HHCDucted, 3.5–4.5 tonsbeats 70% · 16.0TZP15AZ60AJ2NAlso listed as TZPLAD1560AJNDucted, 5 tons and up
EER2beats 99% · 14.0BHP17L24P-**ADucted, 2 tonsbeats 78% · 11.7TZP15AZ60AJ2NAlso listed as TZPLAD1560AJNDucted, 5 tons and up
Heating capacity at 5°Fbeats 99% · 56,500 Btu/hBMY60HHUCNon-ducted, 3.5–4.5 tonsbeats 95% · 48,500 Btu/hTZPLV602PADucted, 3.5–4.5 tons

More comparisons