Both views use the same certified data. This device remembers your choice.
BOREAL vs Nutech heat pumps
Measured against models of the same size and duct type, Nutech scores higher on 3 of the 6 ratings. BOREAL has 28 outdoor models, Nutech has 25 outdoor models. BOREAL and Nutech have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- BOREAL
- Nutech
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | BOREAL | Nutech |
|---|---|---|
| Efficiency index | 44%median — | 52%median — |
| COP at 5°F | 33%median 1.81 | 38%median 1.90 |
| Capacity retention at 5°F | 62% (higher)median 74% | 43% (higher)median 65% |
| HSPF2 | 37%median 8.5 | 63%median 9.3 |
| SEER2 | 44%median 19.8 | 68%median 19.5 |
| EER2 | 42%median 11.3 | 42%median 10.6 |
| Heating capacity at 5°F | 56% (higher)median 13,300 Btu/h | 45% (higher)median 21,400 Btu/h |
| Outdoor models | 28 | 25 |
| AHRI certifications | 48 | 51 |
Share of models meeting each standard
| Standard | BOREAL | Nutech |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 71.4%20 models | 64%16 models |
| CEE 2026 Tier 1 (Split ASHP) | 67.9%19 models | 48%12 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 67.9%19 models | 32%8 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 39.3%11 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- BOREAL
- Nutech
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | BOREAL | Nutech |
|---|---|---|
| Ducted, up to 1.5 tons | 2 · index 44% | 4 · index 52% |
| Ducted, 2 tons | 2 · index 53% | 2 · index 69% |
| Ducted, 2.5 to 3 tons | 3 · index 52% | 7 · index 54% |
| Ducted, 3.5 to 4.5 tons | 1 · index 63% | 6 · index 55% |
| Ducted, 5 tons and up | None | 1 · index 42% |
| Non-ducted, up to 1.5 tons | 15 · index 33% | 4 · index 42% |
| Non-ducted, 2 tons | 3 · index 47% | 1 · index 28% |
| Non-ducted, 2.5 to 3 tons | 8 · index 57% | 5 · index 56% |
| Non-ducted, 3.5 to 4.5 tons | None | 4 · index 44% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BOREALCold-climate score, best model | NutechCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 37.6(50 is the typical model of its size class)KULA12HPJ1OBwith ducted air handler BDUCT12HPJ1DA2 of 2 models qualify · AHRI 217464055 | 65.8(50 is the typical model of its size class) (higher)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M3 of 4 models qualify · AHRI 212941749 |
| Ducted, 2 tons | 50.3(50 is the typical model of its size class)MBRS24HPJ1OE1 of 1 models qualify · AHRI 213829847 | 79.6(50 is the typical model of its size class) (higher)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models qualify · AHRI 212941751 |
| Ducted, 2.5 to 3 tons | 55.5(50 is the typical model of its size class)ENVBR36HPJ1OAwith ducted air handler ENVBR36HPJ1IB4 of 4 models qualify · AHRI 208130265 | 57.7(50 is the typical model of its size class) (higher)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 7 models qualify · AHRI 212941759 |
| Ducted, 3.5 to 4.5 tons | 58.3(50 is the typical model of its size class)ENVBR60HPJ1OAwith ducted air handler ENVBR48HPJ1IB1 of 1 models qualify · AHRI 208130266 | None on this board (0 of 6 models qualify) |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
| Non-ducted, up to 1.5 tons | 74.0(50 is the typical model of its size class) (higher)MBRS18HPJ1OE13 of 15 models qualify · AHRI 211174346 | 57.9(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU11 of 4 models qualify · AHRI 212941744 |
| Non-ducted, 2 tons | 77.3(50 is the typical model of its size class)MBRS24HPJ1OE2 of 3 models qualify · AHRI 211174347 | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5 to 3 tons | 74.7(50 is the typical model of its size class) (higher)MBRS42HPJ1OE7 of 8 models qualify · AHRI 211174350 | 51.5(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 5 models qualify · AHRI 212941758 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | None on this board (0 of 4 models qualify) |
All-around best
| Size and duct type | BOREALAll-around score, best model | NutechAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 55.6(50 is the typical model of its size class)KULA12HPJ1OBwith ducted air handler BDUCT12HPJ1DA2 of 2 models have all five ratings · AHRI 217464055 | 64.7(50 is the typical model of its size class) (higher)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M4 of 4 models have all five ratings · AHRI 212941749 |
| Ducted, 2 tons | 60.8(50 is the typical model of its size class)ENVBR36HPJ1OAwith ducted air handler ENVBR24HPJ1IB2 of 2 models have all five ratings · AHRI 208130264 | 80.2(50 is the typical model of its size class) (higher)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models have all five ratings · AHRI 212941751 |
| Ducted, 2.5 to 3 tons | 53.0(50 is the typical model of its size class)MBRS30HPJ1OE3 of 3 models have all five ratings · AHRI 213829848 | 71.7(50 is the typical model of its size class) (higher)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M7 of 7 models have all five ratings · AHRI 212941759 |
| Ducted, 3.5 to 4.5 tons | 63.3(50 is the typical model of its size class)ENVBR60HPJ1OAwith ducted air handler ENVBR48HPJ1IB1 of 1 models have all five ratings · AHRI 208130266 | 63.5(50 is the typical model of its size class) (higher)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M6 of 6 models have all five ratings · AHRI 212941765 |
| Ducted, 5 tons and up | No models in this size class | 41.9(50 is the typical model of its size class)NOE30U-60HFN1-MR0with ducted air handler NVC-60HWFN11 of 1 models have all five ratings · AHRI 212941774 |
| Non-ducted, up to 1.5 tons | 79.6(50 is the typical model of its size class) (higher)KULA09HPL1OBwith ductless indoor unit KULA09HPL1IB15 of 15 models have all five ratings · AHRI 213829841 | 55.4(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU14 of 4 models have all five ratings · AHRI 212941744 |
| Non-ducted, 2 tons | 72.2(50 is the typical model of its size class) (higher)MBRS24HPJ1OE3 of 3 models have all five ratings · AHRI 211174347 | 28.4(50 is the typical model of its size class)NU24WKU1with ductless indoor unit NU24WKU11 of 1 models have all five ratings · AHRI 212941747 |
| Non-ducted, 2.5 to 3 tons | 70.9(50 is the typical model of its size class) (higher)MBRS42HPJ1OE7 of 8 models have all five ratings · AHRI 211174350 | 68.0(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M5 of 5 models have all five ratings · AHRI 212941758 |
| Non-ducted, 3.5 to 4.5 tons | No models in this size class | 48.3(50 is the typical model of its size class)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M4 of 4 models have all five ratings · AHRI 212941764 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | BOREAL | Nutech |
|---|---|---|
| COP at 5°F | beats 89% · 2.21MBRS18HPJ1OENon-ducted, up to 1.5 tons | beats 87% · 2.01NU36WKU1Non-ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 86% · 89%MBRS30HPJ1OEDucted, 2.5 to 3 tons | beats 93% · 108%NOD30-24HFN1-MU0WDucted, 2 tons |
| HSPF2 | beats 82% · 10.0MBRS30HPJ1OENon-ducted, 2.5 to 3 tons | beats 95% · 9.7N5OG-48HFN1-MAlso listed as N2OA-48HFN1-MDucted, 3.5 to 4.5 tons |
| SEER2 | beats 95% · 27.0KULA09HPL1OBNon-ducted, up to 1.5 tons | beats 98% · 21.0N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MDucted, 2.5 to 3 tons |
| EER2 | beats 89% · 14.6KULA09HPL1OBNon-ducted, up to 1.5 tons | beats 75% · 12.2N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MNon-ducted, 2.5 to 3 tons |
| Heating capacity at 5°F | beats 87% · 14,500 Btu/hKULA18HPJ1OBNon-ducted, up to 1.5 tons | beats 93% · 27,000 Btu/hNOD30-24HFN1-MU0WDucted, 2 tons |
In the cold
NEEP cold-climate listings of both manufacturers against all listed models.
- All listed models (median, middle 50% and 80%)
- BOREAL (median, middle 50%)
- Nutech (median, middle 50%)
One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,707 | 100% | 100% | 100% | 100% | 100% |
| All rated models, 17°F | 3,707 | 65% | 68% | 76% | 83% | 92% |
| All rated models, 5°F | 3,707 | 55% | 58% | 67% | 75% | 83% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| All rated models, 47°F | 3,707 | 2.64 | 2.87 | 3.1 | 3.32 | 3.53 |
| All rated models, 17°F | 3,707 | 1.98 | 2.05 | 2.2 | 2.34 | 2.49 |
| All rated models, 5°F | 3,707 | 1.8 | 1.83 | 1.92 | 2.03 | 2.21 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BOREAL, 47°F | 21 | 100% | 100% | 100% | 100% | 100% |
| BOREAL, 17°F | 21 | 75% | 77% | 87% | 91% | 100% |
| BOREAL, 5°F | 21 | 57% | 65% | 70% | 75% | 75% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| BOREAL, 47°F | 21 | 2.99 | 3 | 3.17 | 3.32 | 3.4 |
| BOREAL, 17°F | 21 | 2.03 | 2.05 | 2.12 | 2.3 | 2.4 |
| BOREAL, 5°F | 21 | 1.75 | 1.8 | 1.82 | 1.87 | 2.1 |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Nutech, 47°F | 24 | 100% | 100% | 100% | 100% | 100% |
| Nutech, 17°F | 24 | 62% | 65% | 67% | 71% | 77% |
| Nutech, 5°F | 24 | 54% | 55% | 57% | 63% | 72% |
| Scope, temperature | Models | 10th pct. | 25th | Median | 75th | 90th |
|---|---|---|---|---|---|---|
| Nutech, 47°F | 24 | 2.76 | 3.07 | 3.18 | 3.23 | 3.45 |
| Nutech, 17°F | 24 | 1.97 | 2.09 | 2.17 | 2.25 | 2.41 |
| Nutech, 5°F | 24 | 1.8 | 1.8 | 1.88 | 1.97 | 2.06 |
Source: NEEP ccASHP list · as of