Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Bravo vs McQuay heat pumps
Measured against models of the same size and duct type, McQuay scores higher on 3 of the 6 ratings. Bravo has 3 outdoor models, McQuay has 3 outdoor models. Bravo and McQuay have no QMID on file and are not ranked.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Bravo
- McQuay
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Bravo | McQuay |
|---|---|---|
| Efficiency index | —median — | 32%median — |
| COP at 5°F | —median — | 59%median 2.01 |
| Capacity retention at 5°F | —median — | 27%median 61% |
| HSPF2 | 11%median 8.0 | 17%median 7.8 |
| SEER2 | 7%median 17.0 | 25%median 18.0 |
| EER2 | 1%median 8.5 | 33%median 9.5 |
| Heating capacity at 5°F | —median — | 33%median 22,000 Btu/h |
| Outdoor models | 3 | 3 |
| AHRI certifications | 3 | 3 |
Share of models meeting each standard
| Standard | Bravo | McQuay |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 0%0 models | 33.3%1 models |
| CEE 2026 Tier 1 (Split ASHP) | 0%0 models | 33.3%1 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 0%0 models | 0%0 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 0%0 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Bravo
- McQuay
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Bravo | McQuay |
|---|---|---|
| Non-ducted, up to 1.5 tons | 2 · index — | None |
| Non-ducted, 2 tons | 1 · index — | 1 · index 25% |
| Non-ducted, 2.5–3 tons | None | 2 · index 35% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | BravoCold-climate score, best model | McQuayCold-climate score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 2 models qualify) | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models qualify) | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5–3 tons | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | BravoAll-around score, best model | McQuayAll-around score, best model |
|---|---|---|
| Non-ducted, up to 1.5 tons | None on this board (0 of 2 models have all five ratings) | No models in this size class |
| Non-ducted, 2 tons | None on this board (0 of 1 models have all five ratings) | 25.1(50 is the typical model of its size class)MQIS-184024-HCU216Awith ductless indoor unit MQIS-184024-HWF216A1 of 1 models have all five ratings · AHRI 10276441 |
| Non-ducted, 2.5–3 tons | No models in this size class | 34.7(50 is the typical model of its size class)MQMI-18036-CCU216Awith ductless indoor unit MQMI-18036-CWF216AAlso listed as MQMI-18036-CCU216P2 of 2 models have all five ratings · AHRI 210589167 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Bravo | McQuay |
|---|---|---|
| COP at 5°F | — | beats 87% · 2.01MQMI-18036-CCU216AAlso listed as MQMI-18036-CCU216PNon-ducted, 2.5–3 tons |
| Capacity retention at 5°F | — | beats 35% · 67%MQIS-184024-HCU216ANon-ducted, 2 tons |
| HSPF2 | beats 16% · 8.5BRV-18LS-230VONon-ducted, up to 1.5 tons | beats 21% · 8.5MQIS-184024-HCU216ANon-ducted, 2 tons |
| SEER2 | beats 9% · 17.0BRV-24LS-230VONon-ducted, 2 tons | beats 26% · 18.5MQIS-184024-HCU216ANon-ducted, 2 tons |
| EER2 | beats 2% · 8.7BRV-24LS-230VONon-ducted, 2 tons | beats 33% · 11.0MQIS-184024-HCU216ANon-ducted, 2 tons |
| Heating capacity at 5°F | — | beats 33% · 22,000 Btu/hMQMI-18036-CCU216AAlso listed as MQMI-18036-CCU216PNon-ducted, 2.5–3 tons |