Skip to content

CanAir vs Nutech heat pumps

Measured against models of the same size and duct type, CanAir scores higher on 5 of the 6 ratings. CanAir has 44 outdoor models, Nutech has 25 outdoor models. CanAir and Nutech have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CanAir and Nutech on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, CanAir scores higher on 5 of the 6 ratings.
  • CanAir
  • Nutech
  • Other ranked manufacturers
CanAirNutech

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCanAirNutech
Efficiency index56% (higher)median —52% (higher)median —
COP at 5°F50% (higher)median 1.9138% (higher)median 1.90
Capacity retention at 5°F58% (higher)median 79%43% (higher)median 65%
HSPF270% (higher)median 9.563% (higher)median 9.3
SEER257%median 19.068%median 19.5
EER247% (higher)median 11.242% (higher)median 10.6
Heating capacity at 5°F60% (higher)median 20,000 Btu/h45% (higher)median 21,400 Btu/h
Outdoor models4425
AHRI certifications7451

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCanAirNutech
CEE 2025 Tier 1 (Split ASHP)63.6%28 models64%16 models
CEE 2026 Tier 1 (Split ASHP)61.4%27 models48%12 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)56.8%25 models32%8 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate59.1%26 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • CanAir
  • Nutech
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCanAirNutech
Ducted, up to 1.5 tons6 · index 50%4 · index 52%
Ducted, 2 tons3 · index 57%2 · index 69%
Ducted, 2.5 to 3 tons10 · index 52%7 · index 54%
Ducted, 3.5 to 4.5 tons6 · index 49%6 · index 55%
Ducted, 5 tons and up1 · index 42%1 · index 42%
Non-ducted, up to 1.5 tons14 · index 62%4 · index 42%
Non-ducted, 2 tons4 · index 60%1 · index 28%
Non-ducted, 2.5 to 3 tons6 · index 60%5 · index 56%
Non-ducted, 3.5 to 4.5 tons1 · index 78%4 · index 44%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCanAirCold-climate score, best modelNutechCold-climate score, best model
Ducted, up to 1.5 tons64.2(50 is the typical model of its size class)MOX430U-18HFN1-Mwith ducted air handler MAC-24HWDN1-MN0Also listed as CDH2018C214 of 5 models qualify · AHRI 20955033365.8(50 is the typical model of its size class) (higher)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M3 of 4 models qualify · AHRI 212941749
Ducted, 2 tons67.6(50 is the typical model of its size class)MOX430-24HFN1-MR0with ducted air handler MAC-24HWDN1-MN04 of 4 models qualify · AHRI 20955032879.6(50 is the typical model of its size class) (higher)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models qualify · AHRI 212941751
Ducted, 2.5 to 3 tons78.7(50 is the typical model of its size class) (higher)MOE31U-36HFN1-Mwith ducted air handler MAC-36HWFN1-MAlso listed as CDH2036C217 of 10 models qualify · AHRI 20955033657.7(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 7 models qualify · AHRI 212941759
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)C28MC548H214 of 6 models qualify · AHRI 207683272None on this board (0 of 6 models qualify)
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)C28SCH06H21with ductless indoor unit C28SEH06H217 of 14 models qualify · AHRI 20768325557.9(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU11 of 4 models qualify · AHRI 212941744
Non-ducted, 2 tons85.5(50 is the typical model of its size class)C28SCH24H21with ductless indoor unit C28SEH24H213 of 4 models qualify · AHRI 207683259None on this board (0 of 1 models qualify)
Non-ducted, 2.5 to 3 tons80.2(50 is the typical model of its size class) (higher)C28MC436H222 of 6 models qualify · AHRI 21347940751.5(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M2 of 5 models qualify · AHRI 212941758
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class)C28MC548H211 of 1 models qualify · AHRI 207683271None on this board (0 of 4 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCanAirAll-around score, best modelNutechAll-around score, best model
Ducted, up to 1.5 tons63.8(50 is the typical model of its size class)CDH2018C21with ducted air handler CDH2018F215 of 5 models have all five ratings · AHRI 20770656864.7(50 is the typical model of its size class) (higher)NOX330-12HFN1-MW5Wwith ducted air handler NTIU-12HWFN1-M4 of 4 models have all five ratings · AHRI 212941749
Ducted, 2 tons74.4(50 is the typical model of its size class)C28MC324H214 of 4 models have all five ratings · AHRI 20768326680.2(50 is the typical model of its size class) (higher)NOD30-24HFN1-MU0Wwith ducted air handler NTIU-24HWFN1-M2 of 2 models have all five ratings · AHRI 212941751
Ducted, 2.5 to 3 tons74.7(50 is the typical model of its size class) (higher)C28MC328H2110 of 10 models have all five ratings · AHRI 21347940571.7(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M7 of 7 models have all five ratings · AHRI 212941759
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)C28MC548H216 of 6 models have all five ratings · AHRI 20768327263.5(50 is the typical model of its size class)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M6 of 6 models have all five ratings · AHRI 212941765
Ducted, 5 tons and up41.9(50 is the typical model of its size class)CDH2060C21with ducted air handler CDH2060F211 of 1 models have all five ratings · AHRI 20810122841.9(50 is the typical model of its size class)NOE30U-60HFN1-MR0with ducted air handler NVC-60HWFN11 of 1 models have all five ratings · AHRI 212941774
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)C28SCH06H21with ductless indoor unit C28SEH06H2114 of 14 models have all five ratings · AHRI 20768325555.4(50 is the typical model of its size class)NU9WKU1with ductless indoor unit NU9WKU14 of 4 models have all five ratings · AHRI 212941744
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)C28SCH24H21with ductless indoor unit C28SEH24H214 of 4 models have all five ratings · AHRI 20768325928.4(50 is the typical model of its size class)NU24WKU1with ductless indoor unit NU24WKU11 of 1 models have all five ratings · AHRI 212941747
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)C28MC436H225 of 6 models have all five ratings · AHRI 21347940768.0(50 is the typical model of its size class)N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-M5 of 5 models have all five ratings · AHRI 212941758
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)C28MC548H211 of 1 models have all five ratings · AHRI 20768327148.3(50 is the typical model of its size class)N5OG-48HFN1-MAlso listed as N2OA-48HFN1-M4 of 4 models have all five ratings · AHRI 212941764

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCanAirNutech
COP at 5°Fbeats 97% · 2.39C25SCH12H21Non-ducted, up to 1.5 tonsbeats 87% · 2.01NU36WKU1Non-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 93% · 107%C28SCH06H21Non-ducted, up to 1.5 tonsbeats 93% · 108%NOD30-24HFN1-MU0WDucted, 2 tons
HSPF2beats 99% · 13.6C28SCH06H21Non-ducted, up to 1.5 tonsbeats 95% · 9.7N5OG-48HFN1-MAlso listed as N2OA-48HFN1-MDucted, 3.5 to 4.5 tons
SEER2beats 99% · 20.9C28MC548H21Ducted, 3.5 to 4.5 tonsbeats 98% · 21.0N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MDucted, 2.5 to 3 tons
EER2beats 98% · 16.2C28SCH09H21Non-ducted, up to 1.5 tonsbeats 75% · 12.2N3OJ-27HFN1-MAlso listed as N2OA-27HFN1-MNon-ducted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hC28MC218H22Non-ducted, up to 1.5 tonsbeats 93% · 27,000 Btu/hNOD30-24HFN1-MU0WDucted, 2 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
CanAir vs Nutech: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • CanAir (median, middle 50%)
  • Nutech (median, middle 50%)
Heating capacity, % of its 47°F maximum64%57%COP at maximum capacity1.911.88

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
CanAir: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
CanAir, 47°F38100%100%100%100%100%
CanAir, 17°F3865%70%74%79%83%
CanAir, 5°F3853%57%64%73%81%
CanAir: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
CanAir, 47°F382.72.813.043.293.53
CanAir, 17°F381.992.042.172.272.34
CanAir, 5°F381.81.821.9122.2
Nutech: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Nutech, 47°F24100%100%100%100%100%
Nutech, 17°F2462%65%67%71%77%
Nutech, 5°F2454%55%57%63%72%
Nutech: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Nutech, 47°F242.763.073.183.233.45
Nutech, 17°F241.972.092.172.252.41
Nutech, 5°F241.81.81.881.972.06

Source: NEEP ccASHP list · as of

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter