Skip to content

CARRIER CORPORATION vs Century heat pumps

Measured against models of the same size and duct type, Century scores higher on 4 of the 6 ratings. CARRIER CORPORATION has 64 outdoor models, Century has 63 outdoor models. CARRIER CORPORATION and Century have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
CARRIER CORPORATION and Century on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Century scores higher on 4 of the 6 ratings.
  • CARRIER CORPORATION
  • Century
  • Other ranked manufacturers
CARRIER …Century

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCARRIER CORPORATIONCentury
Efficiency index41%median —54%median —
COP at 5°F20%median 1.7557%median 2.00
Capacity retention at 5°F10%median 40%52%median 65%
HSPF223%median 7.144%median 8.0
SEER246% (higher)median 16.040% (higher)median 15.6
EER277% (higher)median 11.753% (higher)median 11.0
Heating capacity at 5°F6%median 17,250 Btu/h51%median 19,800 Btu/h
Outdoor models6463
AHRI certifications646,901

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCARRIER CORPORATIONCentury
CEE 2025 Tier 1 (Split ASHP)0%0 models44.4%28 models
CEE 2026 Tier 1 (Split ASHP)0%0 models42.9%27 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models27%17 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models30.2%19 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 3 groups where both have models
  • CARRIER CORPORATION
  • Century
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCARRIER CORPORATIONCentury
Ducted, 2.5–3 tons21 · index 41%15 · index 60%
Ducted, 3.5–4.5 tons22 · index 37%18 · index 58%
Ducted, 5 tons and up21 · index 52%1 · index 19%
Ducted, up to 1.5 tonsNone6 · index 48%
Ducted, 2 tonsNone6 · index 42%
Non-ducted, up to 1.5 tonsNone10 · index 50%
Non-ducted, 2 tonsNone2 · index 49%
Non-ducted, 2.5–3 tonsNone8 · index 63%
Non-ducted, 3.5–4.5 tonsNone3 · index 65%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCARRIER CORPORATIONCold-climate score, best modelCenturyCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size class63.7(50 is the typical model of its size class)A-VCD18SA-1with ducted air handler MCD18/24B1A2 of 6 models qualify · AHRI 212940799
Ducted, 2 tonsNo models in this size class66.5(50 is the typical model of its size class)A-VCD24SA-1with ducted air handler B-VCD24SA-11 of 6 models qualify · AHRI 212940802
Ducted, 2.5–3 tonsNone on this board (0 of 21 models qualify)79.9(50 is the typical model of its size class)A-VMH36QV-1A5 of 15 models qualify · AHRI 214415109
Ducted, 3.5–4.5 tonsNone on this board (0 of 22 models qualify)74.9(50 is the typical model of its size class)A-VMH48PV-14 of 18 models qualify · AHRI 214442638
Ducted, 5 tons and upNone on this board (0 of 21 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tonsNo models in this size class89.3(50 is the typical model of its size class)A-VMH06SV-1with ductless indoor unit B-VMH06SV-16 of 10 models qualify · AHRI 212940813
Non-ducted, 2 tonsNo models in this size class84.5(50 is the typical model of its size class)A-VMH24SV-1with ductless indoor unit B-VMH24SV-11 of 2 models qualify · AHRI 212940817
Non-ducted, 2.5–3 tonsNo models in this size class90.9(50 is the typical model of its size class)A-VMH36QV-1A4 of 8 models qualify · AHRI 214415107
Non-ducted, 3.5–4.5 tonsNo models in this size class76.2(50 is the typical model of its size class)A-VMH48PV-12 of 3 models qualify · AHRI 214442637

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCARRIER CORPORATIONAll-around score, best modelCenturyAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class63.4(50 is the typical model of its size class)A-VCD18SA-1with ducted air handler B-VCD18SA-15 of 6 models have all five ratings · AHRI 212940800
Ducted, 2 tonsNo models in this size class72.4(50 is the typical model of its size class)HRG1836S1Pwith indoor coil EAH1P30B+TDR+TXV and furnace GUH97M070B3M5 of 7 models have all five ratings · AHRI 212604310
Ducted, 2.5–3 tons41.3(50 is the typical model of its size class)50GCQ(T,H)04***3A*****1 of 21 models have all five ratings · AHRI 21661284983.7(50 is the typical model of its size class) (higher)A-VMH36QV-1A9 of 13 models have all five ratings · AHRI 214415109
Ducted, 3.5–4.5 tons50.5(50 is the typical model of its size class)50GCQ(T,H)05***3A*****2 of 22 models have all five ratings · AHRI 21661285082.0(50 is the typical model of its size class) (higher)A-VMH48PV-112 of 19 models have all five ratings · AHRI 214442638
Ducted, 5 tons and up51.5(50 is the typical model of its size class) (higher)50GCQ(T,H)06***3A*****1 of 21 models have all five ratings · AHRI 21661303519.3(50 is the typical model of its size class)RHP6000S1A1 of 1 models have all five ratings · AHRI 214076319
Non-ducted, up to 1.5 tonsNo models in this size class92.0(50 is the typical model of its size class)A-VMH06SV-1with ductless indoor unit B-VMH06SV-110 of 10 models have all five ratings · AHRI 212940813
Non-ducted, 2 tonsNo models in this size class84.3(50 is the typical model of its size class)A-VMH24SV-1with ductless indoor unit B-VMH24SV-12 of 2 models have all five ratings · AHRI 212940817
Non-ducted, 2.5–3 tonsNo models in this size class86.4(50 is the typical model of its size class)A-VMH36QV-1A6 of 8 models have all five ratings · AHRI 214415107
Non-ducted, 3.5–4.5 tonsNo models in this size class77.9(50 is the typical model of its size class)A-VMH48PV-12 of 3 models have all five ratings · AHRI 214442637

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCARRIER CORPORATIONCentury
COP at 5°Fbeats 32% · 1.8450GCQ(T,H)05***3A*****Ducted, 3.5–4.5 tonsbeats 98% · 2.88HRG1548S1R-**ADucted, 3.5–4.5 tons
Capacity retention at 5°Fbeats 21% · 40%50GCQ(T,H)06***3A*****Ducted, 5 tons and upbeats 97% · 103%A-VMH36QV-1ANon-ducted, 2.5–3 tons
HSPF2beats 40% · 7.550GCQ(J,L)06***1*Also listed as 50GCQ(J,L)06***5, 50GCQ(J,L)06***6, 50GCQ(M,P)06***1, 50GCQ(M,P)06***6 and 8 moreDucted, 5 tons and upbeats 98% · 13.6A-VMH06SV-1Non-ducted, up to 1.5 tons
SEER2beats 70% · 16.050GCQ(J,L)06***1*Also listed as 50GCQ(J,L)06***5, 50GCQ(J,L)06***6, 50GCQ(M,P)06***1, 50GCQ(M,P)06***6 and 8 moreDucted, 5 tons and upbeats 99% · 20.9A-VMH48PV-1Ducted, 3.5–4.5 tons
EER2beats 89% · 12.050GCQ(J,L)06***1*Also listed as 50GCQ(J,L)06***5, 50GCQ(J,L)06***6, 50GCQ(M,P)06***1, 50GCQ(M,P)06***6 and 8 moreDucted, 5 tons and upbeats 100% · 13.5HRG1548S1R-**ADucted, 3.5–4.5 tons
Heating capacity at 5°Fbeats 9% · 17,900 Btu/h50GCQ(T,H)05***3A*****Ducted, 3.5–4.5 tonsbeats 96% · 20,000 Btu/hA-VMH18DV-1Non-ducted, up to 1.5 tons

More comparisons