Skip to content

Carrier vs Friedrich heat pumps

Measured against models of the same size and duct type, Carrier scores higher on 3 of the 6 ratings. Carrier has 701 outdoor models, Friedrich has 117 outdoor models.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Carrier and Friedrich on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Carrier scores higher on 3 of the 6 ratings.
  • Carrier
  • Friedrich
  • Other ranked manufacturers
CarrierFriedrich

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCarrierFriedrich
Efficiency index47% (higher)median — · 23rd ranked46% (higher)median — · 25th ranked
COP at 5°F58%median 2.00 · 8th ranked58%median 2.10 · 9th ranked
Capacity retention at 5°F32%median 53% · 27th ranked45%median 61% · 20th ranked
HSPF238% (higher)median 7.7 · 21st ranked31% (higher)median 7.5 · 26th ranked
SEER245% (higher)median 15.5 · 20th ranked36% (higher)median 15.2 · 26th ranked
EER259% (higher)median 11.5 · 6th ranked39% (higher)median 10.6 · 26th ranked
Heating capacity at 5°F35%median 18,300 Btu/h · 27th ranked39%median 15,600 Btu/h · 25th ranked
Outdoor models701117
AHRI certifications367,1013,083

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCarrierFriedrich
CEE 2025 Tier 1 (Split ASHP)28.5%200 models37.6%44 models
CEE 2026 Tier 1 (Split ASHP)25.5%179 models37.6%44 models
CEE Advanced Tier (Split ASHP)2%14 models1.7%2 models
Xcel Energy Colorado cold-climate ASHP (2025)17.1%120 models31.6%37 models
DOE Cold Climate Heat Pump Challenge2%14 models1.7%2 models
ENERGY STAR Cold Climate8.8%62 models28.2%33 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 9 groups where both have models
  • Carrier
  • Friedrich
  • All models of the group
Ducted, up to 1.5 tons2.00884 modelsDucted, 2 tons2.00821 modelsDucted, 2.5–3 tons1.901,614 modelsDucted, 3.5–4.5 tons1.911,492 modelsDucted, 5 tons and up1.90239 modelsNon-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsNon-ducted, 3.5–4.5 tons1.97438 modelsNon-ducted, 5 tons and up2.1032 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCarrierFriedrich
Ducted, up to 1.5 tons34 · index 48%21 · index 27%
Ducted, 2 tons100 · index 47%16 · index 45%
Ducted, 2.5–3 tons195 · index 47%22 · index 52%
Ducted, 3.5–4.5 tons256 · index 43%28 · index 47%
Ducted, 5 tons and up67 · index 60%7 · index —
Non-ducted, up to 1.5 tons42 · index 55%19 · index 55%
Non-ducted, 2 tons9 · index 53%6 · index 47%
Non-ducted, 2.5–3 tons31 · index 52%6 · index 61%
Non-ducted, 3.5–4.5 tons17 · index 48%1 · index 45%
Non-ducted, 5 tons and up1 · index 86%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCarrierCold-climate score, best modelFriedrichCold-climate score, best model
Ducted, up to 1.5 tons81.3(50 is the typical model of its size class) (higher)38MARBQ18AA3with ducted air handler 40MBDAQ18XH3Also sold as Arcoaire DLCSRBH18AAK21 of 33 models qualify · AHRI 21113291855.9(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 205048198
Ducted, 2 tons95.9(50 is the typical model of its size class) (higher)38MURAQ24AB3*with indoor coil H,PG7J936 and furnace 927TA48060V1735 of 99 models qualify · AHRI 21676197374.7(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 213829710
Ducted, 2.5–3 tons96.4(50 is the typical model of its size class) (higher)38MURAQ36AB3*with indoor coil H,PG48936 and furnace 927TA60080V2143 of 197 models qualify · AHRI 21676198880.6(50 is the typical model of its size class)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 213829722
Ducted, 3.5–4.5 tons87.7(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*26 of 256 models qualify · AHRI 21335025476.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 214279028
Ducted, 5 tons and up91.5(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 67 models qualify · AHRI 213350251None on this board (0 of 7 models qualify)
Non-ducted, up to 1.5 tons95.0(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAKAlso sold as Payne 38MPRBQ18AA324 of 42 models qualify · AHRI 20782664478.4(50 is the typical model of its size class)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 205048197
Non-ducted, 2 tons86.1(50 is the typical model of its size class) (higher)38MARBQ24AA3with ductless indoor unit 40MBCAQ24XA3Also sold as Arcoaire DLCSRBH24AAK5 of 9 models qualify · AHRI 20768329272.0(50 is the typical model of its size class)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 205123805
Non-ducted, 2.5–3 tons85.9(50 is the typical model of its size class) (higher)MCY-MAP0367HS-UL*7 of 31 models qualify · AHRI 21335025577.2(50 is the typical model of its size class)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 205150421
Non-ducted, 3.5–4.5 tons82.0(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*11 of 17 models qualify · AHRI 21335025041.9(50 is the typical model of its size class)FPHMR42A3A1 of 1 models qualify · AHRI 205141513
Non-ducted, 5 tons and up89.2(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models qualify · AHRI 213350252No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCarrierAll-around score, best modelFriedrichAll-around score, best model
Ducted, up to 1.5 tons85.2(50 is the typical model of its size class) (higher)38MARBQ09AA3with ducted air handler 40MBDQ09---3Also sold as Arcoaire DLCSRBH09AAK32 of 33 models have all five ratings · AHRI 20635032857.7(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A14 of 20 models have all five ratings · AHRI 205048198
Ducted, 2 tons88.8(50 is the typical model of its size class) (higher)25VNA424A*031*with indoor coil CAP**3721AL*+UI and furnace 58TN*A090C17**16Also sold as Bryant Heating and Cooling Systems 284ANV024*0**B90 of 92 models have all five ratings · AHRI 21053300883.5(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 213829710
Ducted, 2.5–3 tons91.0(50 is the typical model of its size class) (higher)MCY-MAP0367HS-UL162 of 203 models have all five ratings · AHRI 1004987886.1(50 is the typical model of its size class)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 213087287
Ducted, 3.5–4.5 tons92.1(50 is the typical model of its size class) (higher)25VNA448A*031*with ducted air handler FE4BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 284ANV048*0**B201 of 253 models have all five ratings · AHRI 21336159180.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 214610153
Ducted, 5 tons and up91.6(50 is the typical model of its size class) (higher)25VNA460A*031*with ducted air handler FE4BNBD60L*+UI40 of 71 models have all five ratings · AHRI 21336159370.1(50 is the typical model of its size class)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 213841738
Non-ducted, up to 1.5 tons93.6(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAKAlso sold as Payne 38MPRBQ18AA342 of 42 models have all five ratings · AHRI 20782664485.1(50 is the typical model of its size class)MRH09Y3JAwith ductless indoor unit MWH09Y3JA19 of 19 models have all five ratings · AHRI 201763897
Non-ducted, 2 tons84.3(50 is the typical model of its size class) (higher)38MARBQ24AA3with ductless indoor unit 40MAHBQ24XA3Also sold as Arcoaire DLCSRBH24AAK9 of 9 models have all five ratings · AHRI 20634813867.5(50 is the typical model of its size class)FPHMR24A3A6 of 6 models have all five ratings · AHRI 204101246
Non-ducted, 2.5–3 tons90.0(50 is the typical model of its size class) (higher)RAV-SP302AT2P-ULwith ductless indoor unit RAV-SM302UTP-UL27 of 31 models have all five ratings · AHRI 20844732469.4(50 is the typical model of its size class)FPHMR36A3A2 of 6 models have all five ratings · AHRI 204101247
Non-ducted, 3.5–4.5 tons87.5(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*17 of 17 models have all five ratings · AHRI 21335025044.5(50 is the typical model of its size class)FPHMR42A3A1 of 1 models have all five ratings · AHRI 205141512
Non-ducted, 5 tons and up85.8(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models have all five ratings · AHRI 213350252No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCarrierFriedrich
COP at 5°Fbeats 100% · 2.70MCY-MAP0367HS-UL*Non-ducted, 2.5–3 tonsbeats 97% · 2.80WFPU17Z243CDucted, up to 1.5 tons
Capacity retention at 5°Fbeats 100% · 160%WDLCURAH18ABKDucted, up to 1.5 tonsbeats 100% · 105%FRP18AZ48AJVCDucted, 3.5–4.5 tons
HSPF2beats 100% · 15.038MPRBQ09AA3Also sold as Arcoaire DLCPRBH09AAKNon-ducted, up to 1.5 tonsbeats 83% · 9.5FPHFR36A3ADucted, 2.5–3 tons
SEER2beats 100% · 23.1MCY-MAP0607HS-UL*Non-ducted, 5 tons and upbeats 96% · 27.5MRH09Y3JANon-ducted, up to 1.5 tons
EER2beats 100% · 13.5T4H5S42*K*AAA*Ducted, 3.5–4.5 tonsbeats 93% · 15.5MRH09Y3JANon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 96,220 Btu/h38MURAQ60AB3*Also sold as Grandaire WDLCURAH60ABKDucted, 3.5–4.5 tonsbeats 100% · 43,500 Btu/hFRP18AZ36AJVCDucted, 2.5–3 tons

More comparisons