Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Carrier vs Friedrich heat pumps
Measured against models of the same size and duct type, Carrier scores higher on 3 of the 6 ratings. Carrier has 701 outdoor models, Friedrich has 117 outdoor models.
New to heat pump ratings? The Simple view explains them in plain words →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Carrier
- Friedrich
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Carrier | Friedrich |
|---|---|---|
| Efficiency index | 47% (higher)median — · 23rd ranked | 46% (higher)median — · 25th ranked |
| COP at 5°F | 58%median 2.00 · 8th ranked | 58%median 2.10 · 9th ranked |
| Capacity retention at 5°F | 32%median 53% · 27th ranked | 45%median 61% · 20th ranked |
| HSPF2 | 38% (higher)median 7.7 · 21st ranked | 31% (higher)median 7.5 · 26th ranked |
| SEER2 | 45% (higher)median 15.5 · 20th ranked | 36% (higher)median 15.2 · 26th ranked |
| EER2 | 59% (higher)median 11.5 · 6th ranked | 39% (higher)median 10.6 · 26th ranked |
| Heating capacity at 5°F | 35%median 18,300 Btu/h · 27th ranked | 39%median 15,600 Btu/h · 25th ranked |
| Outdoor models | 701 | 117 |
| AHRI certifications | 367,101 | 3,083 |
Share of models meeting each standard
| Standard | Carrier | Friedrich |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 28.5%200 models | 37.6%44 models |
| CEE 2026 Tier 1 (Split ASHP) | 25.5%179 models | 37.6%44 models |
| CEE Advanced Tier (Split ASHP) | 2%14 models | 1.7%2 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 17.1%120 models | 31.6%37 models |
| DOE Cold Climate Heat Pump Challenge | 2%14 models | 1.7%2 models |
| ENERGY STAR Cold Climate | 8.8%62 models | 28.2%33 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Carrier
- Friedrich
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Carrier | Friedrich |
|---|---|---|
| Ducted, up to 1.5 tons | 34 · index 48% | 21 · index 27% |
| Ducted, 2 tons | 100 · index 47% | 16 · index 45% |
| Ducted, 2.5–3 tons | 195 · index 47% | 22 · index 52% |
| Ducted, 3.5–4.5 tons | 256 · index 43% | 28 · index 47% |
| Ducted, 5 tons and up | 67 · index 60% | 7 · index — |
| Non-ducted, up to 1.5 tons | 42 · index 55% | 19 · index 55% |
| Non-ducted, 2 tons | 9 · index 53% | 6 · index 47% |
| Non-ducted, 2.5–3 tons | 31 · index 52% | 6 · index 61% |
| Non-ducted, 3.5–4.5 tons | 17 · index 48% | 1 · index 45% |
| Non-ducted, 5 tons and up | 1 · index 86% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CarrierCold-climate score, best model | FriedrichCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 81.3(50 is the typical model of its size class) (higher)38MARBQ18AA3with ducted air handler 40MBDAQ18XH3Also sold as Arcoaire DLCSRBH18AAK21 of 33 models qualify · AHRI 211132918 | 55.9(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A4 of 20 models qualify · AHRI 205048198 |
| Ducted, 2 tons | 95.9(50 is the typical model of its size class) (higher)38MURAQ24AB3*with indoor coil H,PG7J936 and furnace 927TA48060V1735 of 99 models qualify · AHRI 216761973 | 74.7(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU5 of 17 models qualify · AHRI 213829710 |
| Ducted, 2.5–3 tons | 96.4(50 is the typical model of its size class) (higher)38MURAQ36AB3*with indoor coil H,PG48936 and furnace 927TA60080V2143 of 197 models qualify · AHRI 216761988 | 80.6(50 is the typical model of its size class)FRP18AZ36AJVCwith indoor coil TCFZ3621MEAAM and furnace FR801V0504A17UHU5 of 22 models qualify · AHRI 213829722 |
| Ducted, 3.5–4.5 tons | 87.7(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*26 of 256 models qualify · AHRI 213350254 | 76.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR962V1005A21M47 of 28 models qualify · AHRI 214279028 |
| Ducted, 5 tons and up | 91.5(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 67 models qualify · AHRI 213350251 | None on this board (0 of 7 models qualify) |
| Non-ducted, up to 1.5 tons | 95.0(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAKAlso sold as Payne 38MPRBQ18AA324 of 42 models qualify · AHRI 207826644 | 78.4(50 is the typical model of its size class)FPHFR09A3Awith ductless indoor unit FPHFC09A3B18 of 19 models qualify · AHRI 205048197 |
| Non-ducted, 2 tons | 86.1(50 is the typical model of its size class) (higher)38MARBQ24AA3with ductless indoor unit 40MBCAQ24XA3Also sold as Arcoaire DLCSRBH24AAK5 of 9 models qualify · AHRI 207683292 | 72.0(50 is the typical model of its size class)FPHFR24A3Awith ductless indoor unit FPHFC24A3B5 of 6 models qualify · AHRI 205123805 |
| Non-ducted, 2.5–3 tons | 85.9(50 is the typical model of its size class) (higher)MCY-MAP0367HS-UL*7 of 31 models qualify · AHRI 213350255 | 77.2(50 is the typical model of its size class)FPHFR36A3Awith ductless indoor unit FPHSC36A3B2 of 6 models qualify · AHRI 205150421 |
| Non-ducted, 3.5–4.5 tons | 82.0(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*11 of 17 models qualify · AHRI 213350250 | 41.9(50 is the typical model of its size class)FPHMR42A3A1 of 1 models qualify · AHRI 205141513 |
| Non-ducted, 5 tons and up | 89.2(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models qualify · AHRI 213350252 | No models in this size class |
All-around best
| Size and duct type | CarrierAll-around score, best model | FriedrichAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 85.2(50 is the typical model of its size class) (higher)38MARBQ09AA3with ducted air handler 40MBDQ09---3Also sold as Arcoaire DLCSRBH09AAK32 of 33 models have all five ratings · AHRI 206350328 | 57.7(50 is the typical model of its size class)FPHFR09A3Awith ducted air handler FPHFD09A3A14 of 20 models have all five ratings · AHRI 205048198 |
| Ducted, 2 tons | 88.8(50 is the typical model of its size class) (higher)25VNA424A*031*with indoor coil CAP**3721AL*+UI and furnace 58TN*A090C17**16Also sold as Bryant Heating and Cooling Systems 284ANV024*0**B90 of 92 models have all five ratings · AHRI 210533008 | 83.5(50 is the typical model of its size class)FRP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace FR801V0504A17UHU12 of 17 models have all five ratings · AHRI 213829710 |
| Ducted, 2.5–3 tons | 91.0(50 is the typical model of its size class) (higher)MCY-MAP0367HS-UL162 of 203 models have all five ratings · AHRI 10049878 | 86.1(50 is the typical model of its size class)FRP18AZ36AJVCwith ducted air handler FRHMVZ6021SEACA12 of 22 models have all five ratings · AHRI 213087287 |
| Ducted, 3.5–4.5 tons | 92.1(50 is the typical model of its size class) (higher)25VNA448A*031*with ducted air handler FE4BNBD60L*+UIAlso sold as Bryant Heating and Cooling Systems 284ANV048*0**B201 of 253 models have all five ratings · AHRI 213361591 | 80.3(50 is the typical model of its size class)FRP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace FR802V1005A21UH17 of 27 models have all five ratings · AHRI 214610153 |
| Ducted, 5 tons and up | 91.6(50 is the typical model of its size class) (higher)25VNA460A*031*with ducted air handler FE4BNBD60L*+UI40 of 71 models have all five ratings · AHRI 213361593 | 70.1(50 is the typical model of its size class)FWP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace FR97MV1005A21DH1 of 8 models have all five ratings · AHRI 213841738 |
| Non-ducted, up to 1.5 tons | 93.6(50 is the typical model of its size class) (higher)DLCPRBH18AAKwith ductless indoor unit DLFPHBH18XAKAlso sold as Payne 38MPRBQ18AA342 of 42 models have all five ratings · AHRI 207826644 | 85.1(50 is the typical model of its size class)MRH09Y3JAwith ductless indoor unit MWH09Y3JA19 of 19 models have all five ratings · AHRI 201763897 |
| Non-ducted, 2 tons | 84.3(50 is the typical model of its size class) (higher)38MARBQ24AA3with ductless indoor unit 40MAHBQ24XA3Also sold as Arcoaire DLCSRBH24AAK9 of 9 models have all five ratings · AHRI 206348138 | 67.5(50 is the typical model of its size class)FPHMR24A3A6 of 6 models have all five ratings · AHRI 204101246 |
| Non-ducted, 2.5–3 tons | 90.0(50 is the typical model of its size class) (higher)RAV-SP302AT2P-ULwith ductless indoor unit RAV-SM302UTP-UL27 of 31 models have all five ratings · AHRI 208447324 | 69.4(50 is the typical model of its size class)FPHMR36A3A2 of 6 models have all five ratings · AHRI 204101247 |
| Non-ducted, 3.5–4.5 tons | 87.5(50 is the typical model of its size class) (higher)MCY-MAP0487HS-UL*17 of 17 models have all five ratings · AHRI 213350250 | 44.5(50 is the typical model of its size class)FPHMR42A3A1 of 1 models have all five ratings · AHRI 205141512 |
| Non-ducted, 5 tons and up | 85.8(50 is the typical model of its size class)MCY-MAP0607HS-UL*1 of 1 models have all five ratings · AHRI 213350252 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Carrier | Friedrich |
|---|---|---|
| COP at 5°F | beats 100% · 2.70MCY-MAP0367HS-UL*Non-ducted, 2.5–3 tons | beats 97% · 2.80WFPU17Z243CDucted, up to 1.5 tons |
| Capacity retention at 5°F | beats 100% · 160%WDLCURAH18ABKDucted, up to 1.5 tons | beats 100% · 105%FRP18AZ48AJVCDucted, 3.5–4.5 tons |
| HSPF2 | beats 100% · 15.038MPRBQ09AA3Also sold as Arcoaire DLCPRBH09AAKNon-ducted, up to 1.5 tons | beats 83% · 9.5FPHFR36A3ADucted, 2.5–3 tons |
| SEER2 | beats 100% · 23.1MCY-MAP0607HS-UL*Non-ducted, 5 tons and up | beats 96% · 27.5MRH09Y3JANon-ducted, up to 1.5 tons |
| EER2 | beats 100% · 13.5T4H5S42*K*AAA*Ducted, 3.5–4.5 tons | beats 93% · 15.5MRH09Y3JANon-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 100% · 96,220 Btu/h38MURAQ60AB3*Also sold as Grandaire WDLCURAH60ABKDucted, 3.5–4.5 tons | beats 100% · 43,500 Btu/hFRP18AZ36AJVCDucted, 2.5–3 tons |