Century vs TRUST AIR CONDITIONERS heat pumps

Measured against models of the same size and duct type, TRUST AIR CONDITIONERS scores higher on 4 of the 6 ratings. Century has 63 outdoor models, TRUST AIR CONDITIONERS has 42 outdoor models. Century and TRUST AIR CONDITIONERS have no QMID on file and are not ranked. They share hardware: 27 equipment families appear under both names.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Century and TRUST AIR CONDITIONERS on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, TRUST AIR CONDITIONERS scores higher on 4 of the 6 ratings.
  • Century
  • TRUST AIR CONDITIONERS
  • Other ranked manufacturers
CenturyTRUST AI…

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCenturyTRUST AIR CONDITIONERS
Efficiency index55%median —59%median —
COP at 5°F58% (higher)median 2.0053% (higher)median 1.98
Capacity retention at 5°F53%median 65%58%median 70%
HSPF244%median 8.072%median 9.5
SEER240%median 15.665%median 19.8
EER253% (higher)median 11.050% (higher)median 11.4
Heating capacity at 5°F52%median 19,800 Btu/h58%median 20,000 Btu/h
Outdoor models6342
AHRI certifications6,901103

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCenturyTRUST AIR CONDITIONERS
CEE 2025 Tier 1 (Split ASHP)44.4%28 models69%29 models
CEE 2026 Tier 1 (Split ASHP)42.9%27 models66.7%28 models
CEE Advanced Tier (Split ASHP)0%0 models2.4%1 models
Xcel Energy Colorado cold-climate ASHP (2025)27%17 models52.4%22 models
DOE Cold Climate Heat Pump Challenge0%0 models2.4%1 models
ENERGY STAR Cold Climate30.2%19 models57.1%24 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 9 groups where both have models
  • Century
  • TRUST AIR CONDITIONERS
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCenturyTRUST AIR CONDITIONERS
Ducted, up to 1.5 tons6 · index 48%10 · index 62%
Ducted, 2 tons6 · index 42%4 · index 65%
Ducted, 2.5 to 3 tons15 · index 60%10 · index 57%
Ducted, 3.5 to 4.5 tons18 · index 58%8 · index 58%
Ducted, 5 tons and up1 · index 20%1 · index 42%
Non-ducted, up to 1.5 tons10 · index 51%14 · index 60%
Non-ducted, 2 tons2 · index 49%3 · index 62%
Non-ducted, 2.5 to 3 tons8 · index 64%8 · index 61%
Non-ducted, 3.5 to 4.5 tons3 · index 65%5 · index 54%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCenturyCold-climate score, best modelTRUST AIR CONDITIONERSCold-climate score, best model
Ducted, up to 1.5 tons64.2(50 is the typical model of its size class)A-VCD18SA-1with ducted air handler MCD18/24B1A2 of 6 models qualify · AHRI 21294079975.2(50 is the typical model of its size class) (higher)OAH09H/O4S4Pwith ducted air handler IUMDL09H/I43P8 of 10 models qualify · AHRI 208816930
Ducted, 2 tons66.9(50 is the typical model of its size class)A-VCD24SA-1with ducted air handler B-VCD24SA-11 of 6 models qualify · AHRI 21294080280.6(50 is the typical model of its size class) (higher)OUS24H/O4S4Pwith ducted air handler IUMDL24H/I43P4 of 4 models qualify · AHRI 208816929
Ducted, 2.5 to 3 tons79.9(50 is the typical model of its size class)A-VMH36QV-1A5 of 15 models qualify · AHRI 21441510980.0(50 is the typical model of its size class) (higher)OAH36H/O4S41Pwith ducted air handler IUMDL36H/I43P5 of 10 models qualify · AHRI 208280125
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)A-VMH48PV-14 of 18 models qualify · AHRI 21444263886.5(50 is the typical model of its size class) (higher)OAH48H/O4S41Pwith ducted air handler IUMDL48H/I43P5 of 8 models qualify · AHRI 208280127
Ducted, 5 tons and upNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class)A-VMH06SV-1with ductless indoor unit B-VMH06SV-16 of 10 models qualify · AHRI 21294081389.8(50 is the typical model of its size class)OUS09H/O4S4Pwith ductless indoor unit IUMW106H/I41P8 of 14 models qualify · AHRI 208816913
Non-ducted, 2 tons85.5(50 is the typical model of its size class)A-VMH24SV-1with ductless indoor unit B-VMH24SV-11 of 2 models qualify · AHRI 21294081787.1(50 is the typical model of its size class) (higher)OAH24H/O4S4Pwith ductless indoor unit IUMC424H/I41P2 of 3 models qualify · AHRI 208816925
Non-ducted, 2.5 to 3 tons91.3(50 is the typical model of its size class) (higher)A-VMH36QV-1A4 of 8 models qualify · AHRI 21441510780.2(50 is the typical model of its size class)M4H36H/O4S4P3 of 8 models qualify · AHRI 208284491
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class)A-VMH48PV-12 of 3 models qualify · AHRI 21444263776.5(50 is the typical model of its size class)M5H48H/O4S4P4 of 5 models qualify · AHRI 208284494

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCenturyAll-around score, best modelTRUST AIR CONDITIONERSAll-around score, best model
Ducted, up to 1.5 tons63.8(50 is the typical model of its size class)A-VCD18SA-1with ducted air handler B-VCD18SA-15 of 6 models have all five ratings · AHRI 21294080085.4(50 is the typical model of its size class) (higher)OAH09H/O4S4Pwith ducted air handler IUMDL09H/I43P10 of 10 models have all five ratings · AHRI 208816930
Ducted, 2 tons72.2(50 is the typical model of its size class)HRG1836S1Pwith indoor coil EAH1P30B+TDR+TXV and furnace GUH97M070B3M5 of 7 models have all five ratings · AHRI 21260431084.0(50 is the typical model of its size class) (higher)OUS24H/O4S4Pwith ducted air handler IUMDL24H/I43P4 of 4 models have all five ratings · AHRI 208816929
Ducted, 2.5 to 3 tons83.7(50 is the typical model of its size class) (higher)A-VMH36QV-1A9 of 13 models have all five ratings · AHRI 21441510975.4(50 is the typical model of its size class)M3S27H/O4S4P10 of 10 models have all five ratings · AHRI 208284477
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)A-VMH48PV-112 of 19 models have all five ratings · AHRI 21444263882.1(50 is the typical model of its size class)M5H48H/O4S4P8 of 8 models have all five ratings · AHRI 208284495
Ducted, 5 tons and up19.8(50 is the typical model of its size class)RHP6000S1A1 of 1 models have all five ratings · AHRI 21407631941.9(50 is the typical model of its size class) (higher)AH60H/O44Pwith ducted air handler AH60H/I44P1 of 1 models have all five ratings · AHRI 208284013
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class)A-VMH06SV-1with ductless indoor unit B-VMH06SV-110 of 10 models have all five ratings · AHRI 21294081392.3(50 is the typical model of its size class)OUS09H/O4S4Pwith ductless indoor unit IUMW106H/I41P14 of 14 models have all five ratings · AHRI 208816913
Non-ducted, 2 tons84.9(50 is the typical model of its size class)A-VMH24SV-1with ductless indoor unit B-VMH24SV-12 of 2 models have all five ratings · AHRI 21294081784.9(50 is the typical model of its size class)OAH24H/O4S4Pwith ductless indoor unit IUMW124H/I41P3 of 3 models have all five ratings · AHRI 208816917
Non-ducted, 2.5 to 3 tons86.7(50 is the typical model of its size class) (higher)A-VMH36QV-1A6 of 8 models have all five ratings · AHRI 21441510783.4(50 is the typical model of its size class)M4H36H/O4S4P8 of 8 models have all five ratings · AHRI 208284491
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class)A-VMH48PV-12 of 3 models have all five ratings · AHRI 21444263778.0(50 is the typical model of its size class)M5H48H/O4S4P5 of 5 models have all five ratings · AHRI 208284494

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCenturyTRUST AIR CONDITIONERS
COP at 5°Fbeats 98% · 2.88HRG1548S1R-**ADucted, 3.5 to 4.5 tonsbeats 97% · 2.39OUS12H/O4S4PNon-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 97% · 103%A-VMH36QV-1ANon-ducted, 2.5 to 3 tonsbeats 95% · 103%OAH36H/O4S41PNon-ducted, 2.5 to 3 tons
HSPF2beats 99% · 13.6A-VMH06SV-1Non-ducted, up to 1.5 tonsbeats 99% · 10.3OAH48H/O4S41PDucted, 3.5 to 4.5 tons
SEER2beats 99% · 20.9A-VMH48PV-1Ducted, 3.5 to 4.5 tonsbeats 99% · 20.9M5H48H/O4S4PDucted, 3.5 to 4.5 tons
EER2beats 100% · 13.5HRG1548S1R-**ADucted, 3.5 to 4.5 tonsbeats 98% · 16.2OAH09H/O4S4PNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hA-VMH18DV-1Non-ducted, up to 1.5 tonsbeats 98% · 41,000 Btu/hOAH36H/O4S41PNon-ducted, 2.5 to 3 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Century vs TRUST AIR CONDITIONERS: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Century (median, middle 50%)
  • TRUST AIR CONDITIONERS (median, middle 50%)
Heating capacity, % of its 47°F maximum75%64%COP at maximum capacity1.911.98

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
Century: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Century, 47°F20100%100%100%100%100%
Century, 17°F2070%76%79%82%84%
Century, 5°F2062%69%75%81%83%
Century: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Century, 47°F202.772.8333.153.38
Century, 17°F201.972.052.212.32.42
Century, 5°F201.81.821.9122.2
TRUST AIR CONDITIONERS: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
TRUST AIR CONDITIONERS, 47°F40100%100%100%100%100%
TRUST AIR CONDITIONERS, 17°F4065%68%72%78%81%
TRUST AIR CONDITIONERS, 5°F4055%57%64%72%81%
TRUST AIR CONDITIONERS: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
TRUST AIR CONDITIONERS, 47°F402.72.873.063.253.52
TRUST AIR CONDITIONERS, 17°F401.92.052.192.282.41
TRUST AIR CONDITIONERS, 5°F401.81.861.982.032.2

Source: NEEP ccASHP list · as of