Measured against models of the same size and duct type, CLASSIC scores higher on 5 of the 6 ratings. CLASSIC has 32 outdoor models, TUTTOKOOL has 31 outdoor models. CLASSIC and TUTTOKOOL have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- CLASSIC
- TUTTOKOOL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | CLASSIC | TUTTOKOOL |
|---|---|---|
| Efficiency index | 49% (higher)median — | 29% (higher)median — |
| COP at 5°F | 38% (higher)median 1.80 | 12% (higher)median 1.65 |
| Capacity retention at 5°F | 41% (higher)median 70% | 20% (higher)median 41% |
| HSPF2 | 51% (higher)median 9.0 | 30% (higher)median 7.5 |
| SEER2 | 52% (higher)median 20.0 | 25% (higher)median 14.3 |
| EER2 | 49%median 11.5 | 51%median 11.5 |
| Heating capacity at 5°F | 42% (higher)median 16,000 Btu/h | 27% (higher)median 17,300 Btu/h |
| Outdoor models | 32 | 31 |
| AHRI certifications | 48 | 126 |
Share of models meeting each standard
| Standard | CLASSIC | TUTTOKOOL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 65.6%21 models | 6.5%2 models |
| CEE 2026 Tier 1 (Split ASHP) | 59.4%19 models | 6.5%2 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 43.8%14 models | 6.5%2 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 12.5%4 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- CLASSIC
- TUTTOKOOL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | CLASSIC | TUTTOKOOL |
|---|---|---|
| Ducted, up to 1.5 tons | 3 · index 66% | 3 · index 24% |
| Ducted, 2 tons | 1 · index 85% | 5 · index 23% |
| Ducted, 2.5 to 3 tons | 3 · index 57% | 9 · index 30% |
| Ducted, 3.5 to 4.5 tons | 2 · index 54% | 11 · index 31% |
| Ducted, 5 tons and up | None | 3 · index 33% |
| Non-ducted, up to 1.5 tons | 14 · index 47% | 1 · index 25% |
| Non-ducted, 2 tons | 3 · index 53% | 1 · index 28% |
| Non-ducted, 2.5 to 3 tons | 12 · index 38% | 2 · index 37% |
| Non-ducted, 3.5 to 4.5 tons | 3 · index 46% | 1 · index 32% |
| Non-ducted, 5 tons and up | None | 1 · index 7% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CLASSICCold-climate score, best model | TUTTOKOOLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 68.2(50 is the typical model of its size class)MRSVHC12ASwith ducted air handler MFCHC12S2 of 3 models qualify · AHRI 209843001 | None on this board (0 of 3 models qualify) |
| Ducted, 2 tons | 82.7(50 is the typical model of its size class)MRSVHC24ASwith ducted air handler MFCHC24S1 of 1 models qualify · AHRI 209843003 | None on this board (0 of 5 models qualify) |
| Ducted, 2.5 to 3 tons | None on this board (0 of 3 models qualify) | 53.3(50 is the typical model of its size class)TDV-V36WMN1TE1 of 9 models qualify · AHRI 215427955 |
| Ducted, 3.5 to 4.5 tons | None on this board (0 of 2 models qualify) | 54.7(50 is the typical model of its size class)TDV-V48WMN1T1 of 11 models qualify · AHRI 215427957 |
| Ducted, 5 tons and up | No models in this size class | None on this board (0 of 3 models qualify) |
| Non-ducted, up to 1.5 tons | 58.8(50 is the typical model of its size class)MMRSHC18AS210 of 14 models qualify · AHRI 209843033 | None on this board (0 of 1 models qualify) |
| Non-ducted, 2 tons | 75.6(50 is the typical model of its size class)MRSVHC24ASwith ductless indoor unit MUVHC24S2 of 3 models qualify · AHRI 209843008 | None on this board (0 of 1 models qualify) |
| Non-ducted, 2.5 to 3 tons | 51.5(50 is the typical model of its size class) (higher)MMRSHC27AS32 of 12 models qualify · AHRI 209843036 | 44.2(50 is the typical model of its size class)TDV-V36WMN1TE1 of 2 models qualify · AHRI 215427956 |
| Non-ducted, 3.5 to 4.5 tons | 56.2(50 is the typical model of its size class) (higher)MRSVHC48ASwith ductless indoor unit MUVHC48S2 of 3 models qualify · AHRI 209843010 | 32.7(50 is the typical model of its size class)TDV-V48WMN1T1 of 1 models qualify · AHRI 215427958 |
| Non-ducted, 5 tons and up | No models in this size class | None on this board (0 of 1 models qualify) |
All-around best
| Size and duct type | CLASSICAll-around score, best model | TUTTOKOOLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 78.8(50 is the typical model of its size class) (higher)MRSVHC18ASwith ducted air handler MFCHC18S3 of 3 models have all five ratings · AHRI 209843002 | 33.1(50 is the typical model of its size class)TDV-V18WMN1T2 of 3 models have all five ratings · AHRI 215427964 |
| Ducted, 2 tons | 85.0(50 is the typical model of its size class) (higher)MRSVHC24ASwith ducted air handler MFCHC24S1 of 1 models have all five ratings · AHRI 209843003 | 42.7(50 is the typical model of its size class)TDV-V24WMN1T4 of 5 models have all five ratings · AHRI 215427962 |
| Ducted, 2.5 to 3 tons | 75.4(50 is the typical model of its size class) (higher)MMRSHC27AS33 of 3 models have all five ratings · AHRI 209843037 | 63.9(50 is the typical model of its size class)TDV-V36WMN1TE7 of 9 models have all five ratings · AHRI 215427955 |
| Ducted, 3.5 to 4.5 tons | 63.5(50 is the typical model of its size class) (higher)MMRSHC48AS52 of 2 models have all five ratings · AHRI 209843043 | 53.7(50 is the typical model of its size class)TDV-V48WMN1T7 of 11 models have all five ratings · AHRI 215427957 |
| Ducted, 5 tons and up | No models in this size class | 58.3(50 is the typical model of its size class)TDV-V60WMN1T3 of 3 models have all five ratings · AHRI 215427966 |
| Non-ducted, up to 1.5 tons | 72.0(50 is the typical model of its size class) (higher)MRSVHC12ASwith ductless indoor unit MC4VHC12S14 of 14 models have all five ratings · AHRI 209842996 | 24.6(50 is the typical model of its size class)TDV-V18WMN1T1 of 1 models have all five ratings · AHRI 215427965 |
| Non-ducted, 2 tons | 72.9(50 is the typical model of its size class) (higher)MRSVHC24ASwith ductless indoor unit MUVHC24S3 of 3 models have all five ratings · AHRI 209843008 | 27.5(50 is the typical model of its size class)TDV-V24WMN1T1 of 1 models have all five ratings · AHRI 215427963 |
| Non-ducted, 2.5 to 3 tons | 68.0(50 is the typical model of its size class) (higher)MMRSHC27AS310 of 12 models have all five ratings · AHRI 209843036 | 45.6(50 is the typical model of its size class)TDV-V36WMN1TE2 of 2 models have all five ratings · AHRI 215427956 |
| Non-ducted, 3.5 to 4.5 tons | 51.7(50 is the typical model of its size class) (higher)MMRSHC48AS52 of 3 models have all five ratings · AHRI 209843042 | 31.9(50 is the typical model of its size class)TDV-V48WMN1T1 of 1 models have all five ratings · AHRI 215427958 |
| Non-ducted, 5 tons and up | No models in this size class | 6.9(50 is the typical model of its size class)TDV-V60WMN1T1 of 1 models have all five ratings · AHRI 215427959 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | CLASSIC | TUTTOKOOL |
|---|---|---|
| COP at 5°F | beats 92% · 2.27MRSVHC12ASNon-ducted, up to 1.5 tons | beats 29% · 1.80AHP5030E1000ABDucted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 60% · 74%GRHARC09ASA2Non-ducted, up to 1.5 tons | beats 82% · 65%TDV-V60WMN1TDucted, 5 tons and up |
| HSPF2 | beats 98% · 11.2MRSVHC24ASDucted, 2 tons | beats 93% · 8.7TDV-V60WMN1TDucted, 5 tons and up |
| SEER2 | beats 98% · 21.0MMRSHC27AS3Ducted, 2.5 to 3 tons | beats 92% · 17.2TDV-V60WMN1TDucted, 5 tons and up |
| EER2 | beats 85% · 12.5MRSVHC24ASDucted, 2 tons | beats 82% · 12.0AHP5042E1000ADucted, 3.5 to 4.5 tons |
| Heating capacity at 5°F | beats 86% · 14,000 Btu/hMMRSHC18AS2Non-ducted, up to 1.5 tons | beats 86% · 39,000 Btu/hTDV-V60WMN1TDucted, 5 tons and up |