Skip to content

Coast Air vs hykolity heat pumps

Measured against models of the same size and duct type, Coast Air scores higher on 4 of the 6 ratings. Coast Air has 6 outdoor models, hykolity has 6 outdoor models. Coast Air and hykolity have no QMID on file and are not ranked.

New to heat pump ratings? The Simple view explains them in plain words →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Coast Air and hykolity on every ratingPeer scores, 0–100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Coast Air scores higher on 4 of the 6 ratings.
  • Coast Air
  • hykolity
  • Other ranked manufacturers
Coast Airhykolity

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCoast Airhykolity
Efficiency index50% (higher)median —23% (higher)median —
COP at 5°F52% (higher)median 1.9519% (higher)median 1.80
Capacity retention at 5°F16%median 63%25%median 63%
HSPF246% (higher)median 9.119% (higher)median 8.5
SEER254% (higher)median 21.530% (higher)median 19.0
EER248% (higher)median 12.522% (higher)median 10.0
Heating capacity at 5°F26%median 11,700 Btu/h36%median 12,300 Btu/h
Outdoor models66
AHRI certifications66

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCoast Airhykolity
CEE 2025 Tier 1 (Split ASHP)66.7%4 models66.7%4 models
CEE 2026 Tier 1 (Split ASHP)66.7%4 models50%3 models
CEE Advanced Tier (Split ASHP)0%0 models0%0 models
Xcel Energy Colorado cold-climate ASHP (2025)0%0 models33.3%2 models
DOE Cold Climate Heat Pump Challenge0%0 models0%0 models
ENERGY STAR Cold Climate0%0 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th–90th line · 3 groups where both have models
  • Coast Air
  • hykolity
  • All models of the group
Non-ducted, up to 1.5 tons1.902,417 modelsNon-ducted, 2 tons1.87611 modelsNon-ducted, 2.5–3 tons1.85975 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCoast Airhykolity
Non-ducted, up to 1.5 tons3 · index 60%4 · index 22%
Non-ducted, 2 tons1 · index 51%1 · index 25%
Non-ducted, 2.5–3 tons2 · index 21%1 · index 28%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0–100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0–100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCoast AirCold-climate score, best modelhykolityCold-climate score, best model
Non-ducted, up to 1.5 tonsNone on this board (0 of 3 models qualify)28.4(50 is the typical model of its size class)ACA-2504with ductless indoor unit ACA-25032 of 4 models qualify · AHRI 214584768
Non-ducted, 2 tonsNone on this board (0 of 1 models qualify)None on this board (0 of 1 models qualify)
Non-ducted, 2.5–3 tonsNone on this board (0 of 2 models qualify)None on this board (0 of 1 models qualify)

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0–100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCoast AirAll-around score, best modelhykolityAll-around score, best model
Non-ducted, up to 1.5 tons72.3(50 is the typical model of its size class) (higher)A-CAD09-0Awith ductless indoor unit B-CAD09-0A3 of 3 models have all five ratings · AHRI 21431252627.2(50 is the typical model of its size class)ACA-25314 of 4 models have all five ratings · AHRI 217497281
Non-ducted, 2 tons51.4(50 is the typical model of its size class) (higher)A-CAD24-1Awith ductless indoor unit B-CAD24-1A1 of 1 models have all five ratings · AHRI 21112648924.8(50 is the typical model of its size class)ACA-2512with ductless indoor unit ACA-25111 of 1 models have all five ratings · AHRI 217497283
Non-ducted, 2.5–3 tons20.9(50 is the typical model of its size class)A-CAD36-1Awith ductless indoor unit B-CAD36-1A1 of 2 models have all five ratings · AHRI 21112648828.1(50 is the typical model of its size class) (higher)ACA-25331 of 1 models have all five ratings · AHRI 217497282

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCoast Airhykolity
COP at 5°Fbeats 70% · 2.05A-CAD18-1ANon-ducted, up to 1.5 tonsbeats 26% · 1.80ACA-2512Non-ducted, 2 tons
Capacity retention at 5°Fbeats 23% · 63%A-CAD24-1ANon-ducted, 2 tonsbeats 46% · 70%ACA-2504Non-ducted, up to 1.5 tons
HSPF2beats 85% · 10.8A-CAD09-0ANon-ducted, up to 1.5 tonsbeats 25% · 8.5ACA-2533Non-ducted, 2.5–3 tons
SEER2beats 87% · 25.0A-CAD09-0ANon-ducted, up to 1.5 tonsbeats 35% · 19.0ACA-2533Non-ducted, 2.5–3 tons
EER2beats 89% · 14.5A-CAD09-0ANon-ducted, up to 1.5 tonsbeats 39% · 10.0ACA-2533Non-ducted, 2.5–3 tons
Heating capacity at 5°Fbeats 63% · 11,700 Btu/hA-CAD18-1ANon-ducted, up to 1.5 tonsbeats 78% · 13,000 Btu/hACA-2531Non-ducted, up to 1.5 tons

More comparisons