Both views use the same certified data. This device remembers your choice.
CONTINENTAL vs Hessaire heat pumps
Measured against models of the same size and duct type, CONTINENTAL scores higher on 6 of the 6 ratings. CONTINENTAL has 12 outdoor models, Hessaire has 11 outdoor models. CONTINENTAL and Hessaire have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- CONTINENTAL
- Hessaire
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | CONTINENTAL | Hessaire |
|---|---|---|
| Efficiency index | 68% (higher)median — | 37% (higher)median — |
| COP at 5°F | 48% (higher)median 1.83 | 26% (higher)median 1.75 |
| Capacity retention at 5°F | 75% (higher)median 88% | 44% (higher)median 69% |
| HSPF2 | 73% (higher)median 9.8 | 39% (higher)median 8.5 |
| SEER2 | 72% (higher)median 21.3 | 46% (higher)median 17.5 |
| EER2 | 68% (higher)median 12.5 | 31% (higher)median 10.2 |
| Heating capacity at 5°F | 73% (higher)median 22,000 Btu/h | 47% (higher)median 14,500 Btu/h |
| Outdoor models | 12 | 11 |
| AHRI certifications | 65 | 11 |
Share of models meeting each standard
| Standard | CONTINENTAL | Hessaire |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 100%12 models | 54.5%6 models |
| CEE 2026 Tier 1 (Split ASHP) | 100%12 models | 54.5%6 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 100%12 models | 45.5%5 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 83.3%10 models | 36.4%4 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- CONTINENTAL
- Hessaire
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | CONTINENTAL | Hessaire |
|---|---|---|
| Ducted, 2 tons | 2 · index 50% | 1 · index 48% |
| Ducted, 2.5 to 3 tons | 1 · index 74% | 1 · index 63% |
| Ducted, 3.5 to 4.5 tons | 2 · index 63% | 2 · index 51% |
| Non-ducted, up to 1.5 tons | 4 · index 73% | 5 · index 28% |
| Non-ducted, 2 tons | 2 · index 76% | 2 · index 28% |
| Non-ducted, 2.5 to 3 tons | 2 · index 68% | None |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | CONTINENTALCold-climate score, best model | HessaireCold-climate score, best model |
|---|---|---|
| Ducted, 2 tons | No models in this size class | 62.1(50 is the typical model of its size class)HOC24with ducted air handler HAH241 of 1 models qualify · AHRI 212524529 |
| Ducted, 2.5 to 3 tons | 65.0(50 is the typical model of its size class)CDHAM-28-O3 of 3 models qualify · AHRI 213386542 | 75.2(50 is the typical model of its size class) (higher)HOC36with ducted air handler HAH361 of 1 models qualify · AHRI 212524530 |
| Ducted, 3.5 to 4.5 tons | 58.3(50 is the typical model of its size class)CS18HV48A60with ducted air handler CPFX48AAlso listed as WSEHV4860RA1-C2 of 2 models qualify · AHRI 207335558 | None on this board (0 of 2 models qualify) |
| Non-ducted, up to 1.5 tons | 78.7(50 is the typical model of its size class) (higher)CDHAS22-12-Owith ductless indoor unit CDHAS22-12-I4 of 4 models qualify · AHRI 213386538 | 36.3(50 is the typical model of its size class)H12E1with ductless indoor unit H12E12 of 5 models qualify · AHRI 206913622 |
| Non-ducted, 2 tons | 85.5(50 is the typical model of its size class) (higher)CDHAS26-24-Owith ductless indoor unit CDHAS26-24-I2 of 2 models qualify · AHRI 213386537 | 34.2(50 is the typical model of its size class)H24E2with ductless indoor unit H24E21 of 2 models qualify · AHRI 213286799 |
| Non-ducted, 2.5 to 3 tons | 74.4(50 is the typical model of its size class)CDHAM-36-O2 of 2 models qualify · AHRI 213386544 | No models in this size class |
All-around best
| Size and duct type | CONTINENTALAll-around score, best model | HessaireAll-around score, best model |
|---|---|---|
| Ducted, 2 tons | 60.8(50 is the typical model of its size class) (higher)CS18HV24A36with ducted air handler CPFX24AAlso listed as WSEHV2436RA1-C2 of 2 models have all five ratings · AHRI 207335556 | 48.4(50 is the typical model of its size class)HOC24with ducted air handler HAH241 of 1 models have all five ratings · AHRI 212524529 |
| Ducted, 2.5 to 3 tons | 73.9(50 is the typical model of its size class) (higher)CDHAM-28-O1 of 1 models have all five ratings · AHRI 213386542 | 63.1(50 is the typical model of its size class)HOC36with ducted air handler HAH361 of 1 models have all five ratings · AHRI 212524530 |
| Ducted, 3.5 to 4.5 tons | 63.3(50 is the typical model of its size class) (higher)CS18HV48A60with ducted air handler CPFX48AAlso listed as WSEHV4860RA1-C2 of 2 models have all five ratings · AHRI 207335558 | 57.1(50 is the typical model of its size class)HOC48with ducted air handler HAH482 of 2 models have all five ratings · AHRI 212524531 |
| Non-ducted, up to 1.5 tons | 79.3(50 is the typical model of its size class) (higher)CDHAS22-18-Owith ductless indoor unit CDHAS22-18-I4 of 4 models have all five ratings · AHRI 213386540 | 51.7(50 is the typical model of its size class)H18E2with ductless indoor unit H18E25 of 5 models have all five ratings · AHRI 206913623 |
| Non-ducted, 2 tons | 84.9(50 is the typical model of its size class) (higher)CDHAS26-24-Owith ductless indoor unit CDHAS26-24-I2 of 2 models have all five ratings · AHRI 213386537 | 43.7(50 is the typical model of its size class)H24E2with ductless indoor unit H24E22 of 2 models have all five ratings · AHRI 213286799 |
| Non-ducted, 2.5 to 3 tons | 71.5(50 is the typical model of its size class)CDHAM-36-O2 of 2 models have all five ratings · AHRI 213386544 | No models in this size class |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | CONTINENTAL | Hessaire |
|---|---|---|
| COP at 5°F | beats 97% · 2.22CDHAS22-24-ONon-ducted, 2 tons | beats 75% · 2.05HOC36Ducted, 2.5 to 3 tons |
| Capacity retention at 5°F | beats 90% · 99%CDHAM-36-ONon-ducted, 2.5 to 3 tons | beats 64% · 76%HOC36Ducted, 2.5 to 3 tons |
| HSPF2 | beats 93% · 11.4CDHAS26-24-ONon-ducted, 2 tons | beats 83% · 9.5HOC36Ducted, 2.5 to 3 tons |
| SEER2 | beats 92% · 20.0CDHAM-28-ODucted, 2.5 to 3 tons | beats 82% · 17.5HOC48Ducted, 3.5 to 4.5 tons |
| EER2 | beats 85% · 14.0CDHAS26-12-ONon-ducted, up to 1.5 tons | beats 68% · 13.0H18E2Non-ducted, up to 1.5 tons |
| Heating capacity at 5°F | beats 94% · 36,600 Btu/hCDHAM-36-ONon-ducted, 2.5 to 3 tons | beats 74% · 12,700 Btu/hH18E2Non-ducted, up to 1.5 tons |