Skip to content

Custom Comfort vs KLIMAIRE heat pumps

Measured against models of the same size and duct type, Custom Comfort scores higher on 6 of the 6 ratings. Custom Comfort has 20 outdoor models, KLIMAIRE has 63 outdoor models. Custom Comfort and KLIMAIRE have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Custom Comfort and KLIMAIRE on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Custom Comfort scores higher on 6 of the 6 ratings.
  • Custom Comfort
  • KLIMAIRE
  • Other ranked manufacturers
Custom C…KLIMAIRE

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingCustom ComfortKLIMAIRE
Efficiency index65% (higher)median —53% (higher)median —
COP at 5°F51% (higher)median 1.9848% (higher)median 1.90
Capacity retention at 5°F83% (higher)median 89%45% (higher)median 66%
HSPF284% (higher)median 9.953% (higher)median 9.0
SEER265% (higher)median 18.654% (higher)median 19.0
EER251% (higher)median 11.740% (higher)median 10.0
Heating capacity at 5°F80% (higher)median 29,900 Btu/h45% (higher)median 15,500 Btu/h
Outdoor models2063
AHRI certifications69107

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardCustom ComfortKLIMAIRE
CEE 2025 Tier 1 (Split ASHP)75%15 models52.4%33 models
CEE 2026 Tier 1 (Split ASHP)75%15 models46%29 models
CEE Advanced Tier (Split ASHP)5%1 models1.6%1 models
Xcel Energy Colorado cold-climate ASHP (2025)85%17 models33.3%21 models
DOE Cold Climate Heat Pump Challenge5%1 models1.6%1 models
ENERGY STAR Cold Climate100%20 models0%0 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • Custom Comfort
  • KLIMAIRE
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeCustom ComfortKLIMAIRE
Ducted, up to 1.5 tons5 · index 63%7 · index 68%
Ducted, 2 tons2 · index 67%4 · index 76%
Ducted, 2.5 to 3 tons5 · index 63%7 · index 57%
Ducted, 3.5 to 4.5 tons6 · index 61%5 · index 54%
Ducted, 5 tons and upNone3 · index 56%
Non-ducted, up to 1.5 tons5 · index 76%29 · index 50%
Non-ducted, 2 tons1 · index 85%8 · index 50%
Non-ducted, 2.5 to 3 tons4 · index 70%15 · index 41%
Non-ducted, 3.5 to 4.5 tons4 · index 54%6 · index 41%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeCustom ComfortCold-climate score, best modelKLIMAIRECold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class)CCOXHASZ09HPwith ducted air handler CCOXHASD095 of 5 models qualify · AHRI 21236541575.2(50 is the typical model of its size class)KSIH009-H225-O-2with ducted air handler KDIP09-H26 of 7 models qualify · AHRI 209862170
Ducted, 2 tons79.6(50 is the typical model of its size class)CCOXHASZ24HPwith ducted air handler CCOXHASD242 of 2 models qualify · AHRI 21236541880.6(50 is the typical model of its size class) (higher)KSIE024-H220-O-2with ducted air handler KDIP24-H24 of 4 models qualify · AHRI 209862163
Ducted, 2.5 to 3 tons80.4(50 is the typical model of its size class) (higher)CCOXHAMZ327HP5 of 5 models qualify · AHRI 21263169174.8(50 is the typical model of its size class)KOIF36H2-1Swith ducted air handler KIDF36H2-1S3 of 7 models qualify · AHRI 212316042
Ducted, 3.5 to 4.5 tons86.5(50 is the typical model of its size class) (higher)CCOXHASZ48CHPwith ducted air handler CCOXHASD486 of 6 models qualify · AHRI 21236542074.0(50 is the typical model of its size class)KOIF48H2-1Swith ducted air handler KIDF48H2-1S2 of 5 models qualify · AHRI 212316043
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 3 models qualify)
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)CCOXHASZ06HPwith ductless indoor unit CCOXHAWM065 of 5 models qualify · AHRI 21236540381.1(50 is the typical model of its size class)KSIE009-H221-O-2with ductless indoor unit KSIE009-H221-IW-212 of 29 models qualify · AHRI 209862149
Non-ducted, 2 tons87.1(50 is the typical model of its size class)CCOXHASZ24HPwith ductless indoor unit CCOXHA4C241 of 1 models qualify · AHRI 21236541287.1(50 is the typical model of its size class)KSIH024-H220-O-2with ductless indoor unit KTIS24-H23 of 8 models qualify · AHRI 212316044
Non-ducted, 2.5 to 3 tons83.6(50 is the typical model of its size class) (higher)CCOXHAMZ327HP4 of 4 models qualify · AHRI 21263169051.5(50 is the typical model of its size class)KMIR327-H217-22 of 15 models qualify · AHRI 209862187
Non-ducted, 3.5 to 4.5 tons76.8(50 is the typical model of its size class) (higher)CCOXHASZ60CHPwith ductless indoor unit CCOXHAFC604 of 4 models qualify · AHRI 21236542856.2(50 is the typical model of its size class)KSIR048-H218-2with ductless indoor unit KFUF048-H2G11 of 6 models qualify · AHRI 209862179

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeCustom ComfortAll-around score, best modelKLIMAIREAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)CCOXHASZ09HPwith ducted air handler CCOXHASD095 of 5 models have all five ratings · AHRI 21236541585.4(50 is the typical model of its size class)KSIH009-H225-O-2with ducted air handler KDIP09-H27 of 7 models have all five ratings · AHRI 209862170
Ducted, 2 tons80.2(50 is the typical model of its size class)CCOXHASZ24HPwith ducted air handler CCOXHASD242 of 2 models have all five ratings · AHRI 21236541884.0(50 is the typical model of its size class) (higher)KSIE024-H220-O-2with ducted air handler KDIP24-H24 of 4 models have all five ratings · AHRI 209862163
Ducted, 2.5 to 3 tons81.9(50 is the typical model of its size class) (higher)CCOXHAMZ327HP5 of 5 models have all five ratings · AHRI 21263169172.1(50 is the typical model of its size class)KMIR430-H217-26 of 7 models have all five ratings · AHRI 209862191
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class) (higher)CCOXHAMZ548HP6 of 6 models have all five ratings · AHRI 21236544063.5(50 is the typical model of its size class)KMIR545-H219-24 of 5 models have all five ratings · AHRI 209862197
Ducted, 5 tons and upNo models in this size class57.2(50 is the typical model of its size class)KSIR060-H218-2with ducted air handler KDIS060-H2G1Also listed as KSIR060-H218-2(3)3 of 3 models have all five ratings · AHRI 209862177
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)CCOXHASZ06HPwith ductless indoor unit CCOXHAWM065 of 5 models have all five ratings · AHRI 21236540385.0(50 is the typical model of its size class)KSIH009-H225-O-2with ductless indoor unit KSIH009-H225-IW-224 of 29 models have all five ratings · AHRI 209862153
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)CCOXHASZ24HPwith ductless indoor unit CCOXHAWM241 of 1 models have all five ratings · AHRI 21236540772.9(50 is the typical model of its size class)KSIE024-H220-O-2with ductless indoor unit KUIR24-H26 of 8 models have all five ratings · AHRI 209862165
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)CCOXHAMZ436HP4 of 4 models have all five ratings · AHRI 21236543668.0(50 is the typical model of its size class)KMIR327-H217-210 of 15 models have all five ratings · AHRI 209862187
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)CCOXHAMZ548HP4 of 4 models have all five ratings · AHRI 21236543948.3(50 is the typical model of its size class)KMIR545-H219-24 of 6 models have all five ratings · AHRI 209862196

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingCustom ComfortKLIMAIRE
COP at 5°Fbeats 92% · 2.21CCOXHASZ24HPNon-ducted, 2 tonsbeats 96% · 2.38KSIE018-H220-O-2Non-ducted, up to 1.5 tons
Capacity retention at 5°Fbeats 98% · 103%CCOXHAMZ327HPNon-ducted, 2.5 to 3 tonsbeats 93% · 108%KSIH009-H225-O-2Ducted, up to 1.5 tons
HSPF2beats 99% · 10.3CCOXHASZ48CHPDucted, 3.5 to 4.5 tonsbeats 98% · 12.0KSIH009-H225-O-2Ducted, up to 1.5 tons
SEER2beats 99% · 20.9CCOXHAMZ548HPDucted, 3.5 to 4.5 tonsbeats 98% · 21.0KMIR327-H217-2Ducted, 2.5 to 3 tons
EER2beats 98% · 16.2CCOXHASZ09HPNon-ducted, up to 1.5 tonsbeats 95% · 15.8KSIH009-H225-O-2Non-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 100% · 57,600 Btu/hCCOXHASZ60CHPDucted, 3.5 to 4.5 tonsbeats 95% · 48,500 Btu/hKOIF60H2-1SDucted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
Custom Comfort vs KLIMAIRE: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,710 models (37.8% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • Custom Comfort (median, middle 50%)
  • KLIMAIRE (median, middle 50%)
Heating capacity, % of its 47°F maximum75%62%COP at maximum capacity1.981.97

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,710100%100%100%100%100%
All rated models, 17°F3,71065%68%76%83%92%
All rated models, 5°F3,71055%58%66%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7102.642.873.13.323.53
All rated models, 17°F3,7101.982.052.22.342.49
All rated models, 5°F3,7101.81.831.922.032.21
Custom Comfort: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Custom Comfort, 47°F20100%100%100%100%100%
Custom Comfort, 17°F2074%77%80%84%86%
Custom Comfort, 5°F2063%70%75%81%83%
Custom Comfort: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Custom Comfort, 47°F202.832.983.123.313.49
Custom Comfort, 17°F201.972.062.232.312.39
Custom Comfort, 5°F201.831.91.9822.1
KLIMAIRE: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
KLIMAIRE, 47°F28100%100%100%100%100%
KLIMAIRE, 17°F2862%67%70%79%92%
KLIMAIRE, 5°F2852%57%62%70%77%
KLIMAIRE: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
KLIMAIRE, 47°F282.562.833.123.193.54
KLIMAIRE, 17°F281.981.982.112.272.4
KLIMAIRE, 5°F281.821.91.972.072.21

Source: NEEP ccASHP list · as of