Two ways to read the same certified data. Switch any time; your choice is remembered on this device.
Daikin vs Friedrich: heat pump ratings compared
Against heat pumps of the same size and type, a typical Daikin model beats 50% and a typical Friedrich model 39%. Daikin rates higher overall.
Covers heat pumps sold new today (R-454B and R-32 refrigerant). See older R-410A models · Updated
Daikin
50%
of similar heat pumps beaten by its typical model
About average394 models listed
Friedrich
39%
of similar heat pumps beaten by its typical model
Well below average188 models listed
- Efficiency on a 5°F dayCOP at 5°FDaikin: Beats 46%Friedrich: Beats 46%
- Heating power kept at 5°FCapacity at 5°F vs 47°FDaikin: Beats 48%Friedrich: Beats 36%
- Winter-long heating efficiencyHSPF2Daikin: Beats 38%Friedrich: Beats 31%
- Summer-long cooling efficiencySEER2Daikin: Beats 45%Friedrich: Beats 34%
- Hot-day cooling efficiencyEER2Daikin: Beats 54%Friedrich: Beats 37%
Average (50%)Dashed outline: the other brand, for comparison
Want ranks, distributions per size class and cold-weather curves? Switch to Advanced
Rebate standards
CEE 2025
- Daikin
- 38%
- Friedrich
- 27%
Xcel CC
- Daikin
- 30%
- Friedrich
- 21%
CEE Advanced
- Daikin
- 2%
- Friedrich
- 1%
ENERGY STAR CC
- Daikin
- 17%
- Friedrich
- 22%
All-around best, ducted 2 tons
Balances heating (5°F output and efficiency, HSPF2) and cooling (SEER2, EER2), each rating against units their size.
Showing Ducted, 2 tons (21,000–26,999 Btu/h cooling). What size is my system?
Daikin
- 1DH9VSA241CA*with ducted air handler CAHEA3630C3A*+MBVK16CH*X00ADaikinAlso sold as Amana AZV9SA241CA, Goodman GZV9SA241CA2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 89.2Meets CEE 2025, CEE 2026, CEE Advanced, Xcel CC, DOE CCHP, ENERGY STAR CC
- Heat kept at 5°F
- 100% (Capacity at 5°F vs 47°F)
- Top 10%
- Efficiency at 5°F
- 2.40 (COP at 5°F)
- Great
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 12.2 (EER2)
- Great
- 2RZA24AAVJU*with ducted air handler FBA24A*VJUDaikin2 tons · 24,000 Btu/h · DuctedCold-climate pick, score 58.1Meets CEE 2025, CEE 2026, Xcel CC
- Heat kept at 5°F
- 78% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 9.3 (HSPF2)
- Good
- Cooling efficiency
- 16.2 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
- 3DH4SEA2410A*with ducted air handler L(E,G)M36BDDaikinAlso sold as Goodman GLZS4BA2410A, Amana ALZS4BA2410A2 tons · 22,200 Btu/h · DuctedNot a cold-climate pick: keeps 53% of its heat at 5°FMeets none of the standards tracked here
- Heat kept at 5°F
- 53% (Capacity at 5°F vs 47°F)
- Below the middle
- Efficiency at 5°F
- 2.39 (COP at 5°F)
- Great
- Winter efficiency
- 7.5 (HSPF2)
- Below the middle
- Cooling efficiency
- 15.2 (SEER2)
- Below the middle
- Hot-day cooling
- 12.5 (EER2)
- Great
Friedrich
- 1FRP19AY24AJVCwith indoor coil RCFY2421HEAAM and furnace FR951V0603A17M4Friedrich2 tons · 22,800 Btu/h · DuctedCold-climate pick, score 56.2Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 1.80 (COP at 5°F)
- Below the middle
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 21.0 (SEER2)
- Top 10%
- Hot-day cooling
- 13.0 (EER2)
- Top 10%
- 2RD18AY24AJVCwith ducted air handler RHMVY2417SEACNFriedrich2 tons · 21,400 Btu/h · DuctedCold-climate pick, score 70.3Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 84% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.00 (COP at 5°F)
- Good
- Winter efficiency
- 10.0 (HSPF2)
- Great
- Cooling efficiency
- 19.0 (SEER2)
- Great
- Hot-day cooling
- 12.0 (EER2)
- Good
- 3FRP17AY24AJVCwith indoor coil RCFY2417STANM and furnace FR962V0603A17M4SFriedrich2 tons · 22,400 Btu/h · DuctedCold-climate pick, score 67.4Meets CEE 2025, CEE 2026, Xcel CC, ENERGY STAR CC
- Heat kept at 5°F
- 82% (Capacity at 5°F vs 47°F)
- Good
- Efficiency at 5°F
- 2.10 (COP at 5°F)
- Good
- Winter efficiency
- 9.5 (HSPF2)
- Good
- Cooling efficiency
- 17.0 (SEER2)
- Below the middle
- Hot-day cooling
- 11.7 (EER2)
- Below the middle
These are certified test ratings, not a recommendation for your home. The right size comes from a load calculation by a contractor.