Skip to content

Della vs RUSSELL heat pumps

Measured against models of the same size and duct type, RUSSELL scores higher on 5 of the 6 ratings. Della has 22 outdoor models, RUSSELL has 60 outdoor models. RUSSELL has no QMID on file and is not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
Della and RUSSELL on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, RUSSELL scores higher on 5 of the 6 ratings.
  • Della
  • RUSSELL
  • Other ranked manufacturers
DellaRUSSELL

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDellaRUSSELL
Efficiency index40%median — · 27th ranked49%median —
COP at 5°F44%median 1.80 · 24th ranked80%median 2.20
Capacity retention at 5°F39%median 70% · 26th ranked45%median 58%
HSPF223%median 8.5 · 27th ranked25%median 7.2
SEER235% (higher)median 19.0 · 27th ranked31% (higher)median 14.3
EER229%median 10.0 · 27th ranked42%median 10.6
Heating capacity at 5°F38%median 11,600 Btu/h · 26th ranked43%median 24,200 Btu/h
Outdoor models2260
AHRI certifications221,231

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDellaRUSSELL
CEE 2025 Tier 1 (Split ASHP)54.5%12 models16.7%10 models
CEE 2026 Tier 1 (Split ASHP)45.5%10 models16.7%10 models
CEE Advanced Tier (Split ASHP)0%0 models3.3%2 models
Xcel Energy Colorado cold-climate ASHP (2025)36.4%8 models13.3%8 models
DOE Cold Climate Heat Pump Challenge0%0 models3.3%2 models
ENERGY STAR Cold Climate18.2%4 models21.7%13 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 0 groups where both have models
  • Della
  • RUSSELL
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,647 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDellaRUSSELL
Ducted, up to 1.5 tonsNone2 · index 27%
Ducted, 2 tonsNone7 · index 50%
Ducted, 2.5 to 3 tonsNone17 · index 52%
Ducted, 3.5 to 4.5 tonsNone26 · index 50%
Ducted, 5 tons and upNone8 · index 70%
Non-ducted, up to 1.5 tons16 · index 44%None
Non-ducted, 2 tons3 · index 40%None
Non-ducted, 2.5 to 3 tons3 · index 29%None

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDellaCold-climate score, best modelRUSSELLCold-climate score, best model
Ducted, up to 1.5 tonsNo models in this size classNone on this board (0 of 2 models qualify)
Ducted, 2 tonsNo models in this size class74.8(50 is the typical model of its size class)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU2 of 7 models qualify · AHRI 213372369
Ducted, 2.5 to 3 tonsNo models in this size class80.5(50 is the typical model of its size class)SP18AZ36AJVCwith ducted air handler SHMVZ6021SEACA2 of 17 models qualify · AHRI 210106900
Ducted, 3.5 to 4.5 tonsNo models in this size class76.4(50 is the typical model of its size class)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S962V1005A21M4S4 of 26 models qualify · AHRI 210106968
Ducted, 5 tons and upNo models in this size classNone on this board (0 of 8 models qualify)
Non-ducted, up to 1.5 tons69.8(50 is the typical model of its size class)048-TP-12K2V-23S-OUTwith ductless indoor unit 048-TP-12K2V-23S-IN8 of 16 models qualify · AHRI 213927343No models in this size class
Non-ducted, 2 tonsNone on this board (0 of 3 models qualify)No models in this size class
Non-ducted, 2.5 to 3 tonsNone on this board (0 of 3 models qualify)No models in this size class

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDellaAll-around score, best modelRUSSELLAll-around score, best model
Ducted, up to 1.5 tonsNo models in this size class34.6(50 is the typical model of its size class)SP15AZ18AJ2Nwith ducted air handler SH2CZ2417STANN2 of 2 models have all five ratings · AHRI 211627516
Ducted, 2 tonsNo models in this size class83.6(50 is the typical model of its size class)SP18AZ24AJVCwith indoor coil TCFZ2421HEAAM and furnace S951V0403A17UHU4 of 7 models have all five ratings · AHRI 213372369
Ducted, 2.5 to 3 tonsNo models in this size class87.1(50 is the typical model of its size class)SP18AZ36AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z6 of 17 models have all five ratings · AHRI 210589394
Ducted, 3.5 to 4.5 tonsNo models in this size class80.4(50 is the typical model of its size class)SP18AZ48AJVCwith indoor coil TCFZ6021SEAAM and furnace S802VA100521Z9 of 26 models have all five ratings · AHRI 210589350
Ducted, 5 tons and upNo models in this size class70.0(50 is the typical model of its size class)SP15AZ60AJ2Nwith indoor coil TCFZ6024STANM and furnace S97MV1005A21DHS1 of 8 models have all five ratings · AHRI 212387320
Non-ducted, up to 1.5 tons71.5(50 is the typical model of its size class)048-TP-12K2V-23S-OUTwith ductless indoor unit 048-TP-12K2V-23S-IN10 of 16 models have all five ratings · AHRI 213927343No models in this size class
Non-ducted, 2 tons54.2(50 is the typical model of its size class)048-TP-24K2V-20S-OUTwith ductless indoor unit 048-TP-24K2V-20S-IN2 of 3 models have all five ratings · AHRI 213927345No models in this size class
Non-ducted, 2.5 to 3 tons31.1(50 is the typical model of its size class)048-TL-36K-MODU3 of 3 models have all five ratings · AHRI 211042067No models in this size class

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDellaRUSSELL
COP at 5°Fbeats 89% · 2.21048-TP-18K2V-22S-OUTNon-ducted, up to 1.5 tonsbeats 98% · 2.60SP15AZ60AJ2NDucted, 5 tons and up
Capacity retention at 5°Fbeats 66% · 77%048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tonsbeats 100% · 105%SP18AZ48AJVCDucted, 3.5 to 4.5 tons
HSPF2beats 58% · 9.5048-TP-12K2V-23S-OUTNon-ducted, up to 1.5 tonsbeats 75% · 9.5RD17AZ24AJ3NDucted, 2 tons
SEER2beats 79% · 23.5048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tonsbeats 92% · 20.0SP18AZ36AJVCDucted, 2.5 to 3 tons
EER2beats 68% · 13.0048-TP-9K2V-23S-OUTNon-ducted, up to 1.5 tonsbeats 91% · 12.5SP18AZ36AJVCDucted, 2.5 to 3 tons
Heating capacity at 5°Fbeats 79% · 13,000 Btu/h048-TL-18K-MODUNon-ducted, up to 1.5 tonsbeats 100% · 43,500 Btu/hSP18AZ36AJVCDucted, 2.5 to 3 tons

More comparisons

    Send feedback

    Attached to every report

    A screenshot of this page, its address, your device and browser, recent errors and failed requests on this page, and your last clicks. Passwords and card numbers are never included. Privacy

    Ctrl or ⌘ + Enter