Dettson vs TUTTO KOOL heat pumps
Measured against models of the same size and duct type, Dettson scores higher on 6 of the 6 ratings. Dettson has 10 outdoor models, TUTTO KOOL has 9 outdoor models. Dettson and TUTTO KOOL have no QMID on file and are not ranked.
Simple view, for homeowners: top picks by size and what each rating measures →
CompareData as of updated · sources
Against comparable models
Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
- Dettson
- TUTTO KOOL
- Other ranked manufacturers
Source: AHRI Directory, NEEP · as of
| Rating | Dettson | TUTTO KOOL |
|---|---|---|
| Efficiency index | 52% (higher)median — | 23% (higher)median — |
| COP at 5°F | 55% (higher)median 2.00 | 26% (higher)median 1.80 |
| Capacity retention at 5°F | 71% (higher)median 82% | 28% (higher)median 61% |
| HSPF2 | 78% (higher)median 9.6 | 11% (higher)median 7.8 |
| SEER2 | 42% (higher)median 15.4 | 24% (higher)median 19.0 |
| EER2 | 30% (higher)median 10.6 | 13% (higher)median 9.0 |
| Heating capacity at 5°F | 81% (higher)median 25,000 Btu/h | 40% (higher)median 11,600 Btu/h |
| Outdoor models | 10 | 9 |
| AHRI certifications | 36 | 9 |
Share of models meeting each standard
| Standard | Dettson | TUTTO KOOL |
|---|---|---|
| CEE 2025 Tier 1 (Split ASHP) | 60%6 models | 33.3%3 models |
| CEE 2026 Tier 1 (Split ASHP) | 60%6 models | 22.2%2 models |
| CEE Advanced Tier (Split ASHP) | 0%0 models | 0%0 models |
| Xcel Energy Colorado cold-climate ASHP (2025) | 80%8 models | 22.2%2 models |
| DOE Cold Climate Heat Pump Challenge | 0%0 models | 0%0 models |
| ENERGY STAR Cold Climate | 100%10 models | 0%0 models |
Sizes and duct types offered
Models in each peer group, with the efficiency index of those models against the rest of the group.
- Dettson
- TUTTO KOOL
- All models of the group
Raw ratings are only placed side by side within one size and duct type, where they are comparable.
Source: AHRI Directory · as of
| Size and duct type | Dettson | TUTTO KOOL |
|---|---|---|
| Ducted, up to 1.5 tons | 3 · index 51% | None |
| Ducted, 2 tons | 2 · index 57% | None |
| Ducted, 2.5 to 3 tons | 3 · index 49% | None |
| Ducted, 3.5 to 4.5 tons | 2 · index 53% | None |
| Non-ducted, up to 1.5 tons | None | 5 · index 22% |
| Non-ducted, 2 tons | None | 2 · index 26% |
| Non-ducted, 2.5 to 3 tons | None | 2 · index 25% |
Cold-climate and all-around picks, size class by size class
Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.
Cold-climate picks
| Size and duct type | DettsonCold-climate score, best model | TUTTO KOOLCold-climate score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 65.9(50 is the typical model of its size class)EVD-24-O*with ducted air handler MAC24H1418E3 of 3 models qualify · AHRI 213386698 | No models in this size class |
| Ducted, 2 tons | 75.7(50 is the typical model of its size class)MHD-24with ducted air handler MHD-CC2.0-17.5-M2 of 2 models qualify · AHRI 210365428 | No models in this size class |
| Ducted, 2.5 to 3 tons | 78.7(50 is the typical model of its size class)EVD-36-Owith ducted air handler MAC36H2124E3 of 3 models qualify · AHRI 213160483 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 74.0(50 is the typical model of its size class)EVD-48-Owith ducted air handler EVD-48-I2 of 2 models qualify · AHRI 210365435 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 30.5(50 is the typical model of its size class)TK1912E5CA-Owith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O2 of 5 models qualify · AHRI 213244555 |
| Non-ducted, 2 tons | No models in this size class | None on this board (0 of 2 models qualify) |
| Non-ducted, 2.5 to 3 tons | No models in this size class | None on this board (0 of 2 models qualify) |
All-around best
| Size and duct type | DettsonAll-around score, best model | TUTTO KOOLAll-around score, best model |
|---|---|---|
| Ducted, up to 1.5 tons | 63.8(50 is the typical model of its size class)EVD-18-Owith ducted air handler EVD-18-I3 of 3 models have all five ratings · AHRI 210365431 | No models in this size class |
| Ducted, 2 tons | 66.0(50 is the typical model of its size class)EVD-24-Owith ducted air handler EVD-24-I2 of 2 models have all five ratings · AHRI 210365432 | No models in this size class |
| Ducted, 2.5 to 3 tons | 68.5(50 is the typical model of its size class)EVD-36-O-Swith ducted air handler EVD-36-I3 of 3 models have all five ratings · AHRI 213488871 | No models in this size class |
| Ducted, 3.5 to 4.5 tons | 53.4(50 is the typical model of its size class)EVD-48-Owith ducted air handler EVD-48-I2 of 2 models have all five ratings · AHRI 210365435 | No models in this size class |
| Non-ducted, up to 1.5 tons | No models in this size class | 24.8(50 is the typical model of its size class)TK1912E5CA-Owith ductless indoor unit TK1912E5CA-IAlso listed as TK1912E5CD-O3 of 5 models have all five ratings · AHRI 213244555 |
| Non-ducted, 2 tons | No models in this size class | 26.1(50 is the typical model of its size class)TK1924E5CD-Owith ductless indoor unit TK1924E5CD-I1 of 2 models have all five ratings · AHRI 213244557 |
| Non-ducted, 2.5 to 3 tons | No models in this size class | 24.9(50 is the typical model of its size class)TK1936E5CD-Owith ductless indoor unit TK1936E5CD-I1 of 2 models have all five ratings · AHRI 213244558 |
Standout model on each rating
Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
| Rating | Dettson | TUTTO KOOL |
|---|---|---|
| COP at 5°F | beats 78% · 2.21MHD-18Ducted, up to 1.5 tons | beats 31% · 1.80TK1924E5CD-ONon-ducted, 2 tons |
| Capacity retention at 5°F | beats 92% · 92%EVD-48-ODucted, 3.5 to 4.5 tons | beats 48% · 70%TK1912E5CA-OAlso listed as TK1912E5CD-ONon-ducted, up to 1.5 tons |
| HSPF2 | beats 93% · 10.0EVD-36-ODucted, 2.5 to 3 tons | beats 26% · 8.5TK1936E5CD-ONon-ducted, 2.5 to 3 tons |
| SEER2 | beats 66% · 17.4EVD-24-ODucted, 2 tons | beats 36% · 19.0TK1924E5CD-ONon-ducted, 2 tons |
| EER2 | beats 72% · 12.4EVD-18-ODucted, up to 1.5 tons | beats 24% · 10.0TK1924E5CD-ONon-ducted, 2 tons |
| Heating capacity at 5°F | beats 96% · 38,000 Btu/hEVD-36-O-SDucted, 2.5 to 3 tons | beats 62% · 11,600 Btu/hTK1918W5CD-ONon-ducted, up to 1.5 tons |