Skip to content

DIRECT AIR vs Mitsutomo heat pumps

Measured against models of the same size and duct type, Mitsutomo scores higher on 4 of the 6 ratings. DIRECT AIR has 68 outdoor models, Mitsutomo has 31 outdoor models. DIRECT AIR and Mitsutomo have no QMID on file and are not ranked.

Simple view, for homeowners: top picks by size and what each rating measures →

CompareData as of updated · sources

Against comparable models

Each cell is the share of same-size, same-type models that the manufacturer’s typical model beats (50% is typical); the higher score is in bold. Raw medians are underneath for context: they depend on which sizes each one makes, so they are not compared.
DIRECT AIR and Mitsutomo on every ratingPeer scores, 0 to 100 · grey ticks: every ranked manufacturer · shaded: the middle half of each one’s modelsMeasured against models of the same size and duct type, Mitsutomo scores higher on 4 of the 6 ratings.
  • DIRECT AIR
  • Mitsutomo
  • Other ranked manufacturers
DIRECT A…Mitsutomo

Source: AHRI Directory, NEEP · as of

Average peer percentile, raw median and rank among ranked manufacturers
RatingDIRECT AIRMitsutomo
Efficiency index58%median —60%median —
COP at 5°F50% (higher)median 1.9149% (higher)median 1.95
Capacity retention at 5°F59%median 79%73%median 88%
HSPF260%median 9.272%median 9.5
SEER256%median 19.060%median 20.0
EER253% (higher)median 11.750% (higher)median 11.7
Heating capacity at 5°F55%median 16,800 Btu/h69%median 22,600 Btu/h
Outdoor models6831
AHRI certifications16271

Share of models meeting each standard

Percent of each manufacturer’s models with a qualifying certification
StandardDIRECT AIRMitsutomo
CEE 2025 Tier 1 (Split ASHP)61.8%42 models71%22 models
CEE 2026 Tier 1 (Split ASHP)60.3%41 models71%22 models
CEE Advanced Tier (Split ASHP)1.5%1 models3.2%1 models
Xcel Energy Colorado cold-climate ASHP (2025)54.4%37 models67.7%21 models
DOE Cold Climate Heat Pump Challenge1.5%1 models3.2%1 models
ENERGY STAR Cold Climate50%34 models77.4%24 models

Sizes and duct types offered

Models in each peer group, with the efficiency index of those models against the rest of the group.
Side by side, inside each size and duct typeShape: every model of the group · bars: each manufacturer’s middle half, median dot, 10th to 90th line · 8 groups where both have models
  • DIRECT AIR
  • Mitsutomo
  • All models of the group
Ducted, up to 1.5 tons2.00915 modelsDucted, 2 tons2.00832 modelsDucted, 2.5 to 3 tons1.901,646 modelsDucted, 3.5 to 4.5 tons1.911,552 modelsDucted, 5 tons and up1.90251 modelsNon-ducted, up to 1.5 tons1.902,584 modelsNon-ducted, 2 tons1.83664 modelsNon-ducted, 2.5 to 3 tons1.841,049 modelsNon-ducted, 3.5 to 4.5 tons1.97445 modelsmedian

Raw ratings are only placed side by side within one size and duct type, where they are comparable.

Source: AHRI Directory · as of

Models per peer group · efficiency index within the group
Size and duct typeDIRECT AIRMitsutomo
Ducted, up to 1.5 tons12 · index 61%5 · index 65%
Ducted, 2 tons5 · index 67%2 · index 73%
Ducted, 2.5 to 3 tons13 · index 55%8 · index 66%
Ducted, 3.5 to 4.5 tons11 · index 58%6 · index 61%
Ducted, 5 tons and up2 · index 48%None
Non-ducted, up to 1.5 tons27 · index 56%10 · index 56%
Non-ducted, 2 tons6 · index 58%2 · index 48%
Non-ducted, 2.5 to 3 tons9 · index 60%9 · index 59%
Non-ducted, 3.5 to 4.5 tons4 · index 58%4 · index 51%

Cold-climate and all-around picks, size class by size class

Each manufacturer’s best model on each board in every size and duct type, side by side; the higher score is in bold. Both scores are 0 to 100 against every model of that size class (the line on each bar is 50, the typical model there), so the two compare fairly even when they make different sizes.

Cold-climate picks

Best cold-climate pick per size and duct type (keeps at least 70% of its heat at 5°F). Qualifies when its capacity retention at 5°F (capacity at 5°F as a share of capacity at 47°F) is at least 70% and Capacity retention at 5°F, COP at 5°F, HSPF2 are all rated. Score = the equal-weight mean of its peer percentiles on Capacity retention at 5°F, COP at 5°F, HSPF2 (share of the other models in its peer group it beats, 0 to 100), all from one certified pairing: in each duct type a model is sold in, its qualifying pairing of that type with the best score; equal scores (one decimal) go to the higher heating capacity at 5°F.
Size and duct typeDIRECT AIRCold-climate score, best modelMitsutomoCold-climate score, best model
Ducted, up to 1.5 tons75.2(50 is the typical model of its size class)DIRM-09HXPRO28-1Zwith ducted air handler DIRM-09HP-DUH9 of 12 models qualify · AHRI 20774374975.2(50 is the typical model of its size class)HO-SZ09-AB-Qwith ducted air handler HD-UZ09-AB-Q5 of 5 models qualify · AHRI 214056566
Ducted, 2 tons80.6(50 is the typical model of its size class) (higher)DIRM-24DA25-1Zwith ducted air handler DIRM-24HP-DU4 of 5 models qualify · AHRI 20774375979.6(50 is the typical model of its size class)HO-SZ24-AB-Qwith ducted air handler HD-UZ24-AB-Q2 of 2 models qualify · AHRI 214056569
Ducted, 2.5 to 3 tons79.8(50 is the typical model of its size class)DIRM-36MAGICPRO20-OUwith ducted air handler HG8J936+TD5 of 13 models qualify · AHRI 21289748480.4(50 is the typical model of its size class) (higher)HO-MT28-AC-Q7 of 8 models qualify · AHRI 213785766
Ducted, 3.5 to 4.5 tons75.1(50 is the typical model of its size class)DIRM-48HXPRO28-5Z3 of 11 models qualify · AHRI 20774379586.5(50 is the typical model of its size class) (higher)HO-SZ48-BB-Qwith ducted air handler HD-UZ48-BB-Q6 of 6 models qualify · AHRI 214056577
Ducted, 5 tons and upNone on this board (0 of 2 models qualify)No models in this size class
Non-ducted, up to 1.5 tons89.8(50 is the typical model of its size class) (higher)DIRM-06HXPRO28-1Zwith ductless indoor unit DIRM-06HP-WM20 of 27 models qualify · AHRI 20774372383.1(50 is the typical model of its size class)HO-SZ06-AB-Qwith ductless indoor unit HJ-UZ06-AB-Q7 of 10 models qualify · AHRI 211306397
Non-ducted, 2 tons87.1(50 is the typical model of its size class)DIRM-24HXPRO28-1Zwith ductless indoor unit DIRM-24HP-CA5 of 6 models qualify · AHRI 20774374487.1(50 is the typical model of its size class)HO-SZ24-AB-Qwith ductless indoor unit HC-UZ24-AB-Q1 of 2 models qualify · AHRI 214056565
Non-ducted, 2.5 to 3 tons80.2(50 is the typical model of its size class)DIRM-36HXPRO28-4Z2 of 9 models qualify · AHRI 20774379187.5(50 is the typical model of its size class) (higher)HO-MQ36-AC-Q6 of 9 models qualify · AHRI 213785768
Non-ducted, 3.5 to 4.5 tons76.5(50 is the typical model of its size class)DIRM-48HXPRO28-5Z2 of 4 models qualify · AHRI 20774379480.7(50 is the typical model of its size class) (higher)HO-MP48-AB-Q4 of 4 models qualify · AHRI 211306410

All-around best

Best all-around model per size and duct type. Score = 50% heating, the mean of its peer percentiles on COP at 5°F, Capacity retention at 5°F, HSPF2, plus 50% cooling, the mean of its peer percentiles on SEER2 and EER2 (share of the other models in its peer group it beats, 0 to 100). All five ratings are required; there is no minimum heat kept at 5°F. In each duct type a model is sold in, it is scored on its pairing of that type with the best score; equal scores (one decimal) go to the higher cold-climate score, then the higher heating capacity at 5°F.
Size and duct typeDIRECT AIRAll-around score, best modelMitsutomoAll-around score, best model
Ducted, up to 1.5 tons85.4(50 is the typical model of its size class)DIRM-09HXPRO28-1Zwith ducted air handler DIRM-09HP-DUH11 of 12 models have all five ratings · AHRI 20774374985.4(50 is the typical model of its size class)HO-SZ09-AB-Qwith ducted air handler HD-UZ09-AB-Q5 of 5 models have all five ratings · AHRI 214056566
Ducted, 2 tons84.0(50 is the typical model of its size class) (higher)DIRM-24DA25-1Zwith ducted air handler DIRM-24HP-DU4 of 5 models have all five ratings · AHRI 20774375980.2(50 is the typical model of its size class)HO-SZ24-AB-Qwith ducted air handler HD-UZ24-AB-Q2 of 2 models have all five ratings · AHRI 214056569
Ducted, 2.5 to 3 tons75.4(50 is the typical model of its size class)DIRM-27DA25-3Z10 of 13 models have all five ratings · AHRI 20774377783.7(50 is the typical model of its size class) (higher)HO-MQ36-AC-Q8 of 8 models have all five ratings · AHRI 213785769
Ducted, 3.5 to 4.5 tons82.1(50 is the typical model of its size class)DIRM-48HXPRO28-5Z6 of 11 models have all five ratings · AHRI 20774379582.1(50 is the typical model of its size class)HO-MP48-AB-Q6 of 6 models have all five ratings · AHRI 211306411
Ducted, 5 tons and up54.3(50 is the typical model of its size class)MOE30U-60HFN1-Mwith ducted air handler MHG-60HWFN1-MW2 of 2 models have all five ratings · AHRI 203269797No models in this size class
Non-ducted, up to 1.5 tons92.3(50 is the typical model of its size class) (higher)DIRM-06HXPRO28-1Zwith ductless indoor unit DIRM-06HP-WM27 of 27 models have all five ratings · AHRI 20774372385.0(50 is the typical model of its size class)HO-SZ09-AB-Qwith ductless indoor unit HW-SZ09-AB-Q10 of 10 models have all five ratings · AHRI 211306393
Non-ducted, 2 tons84.9(50 is the typical model of its size class) (higher)DIRM-24HXPRO28-1Zwith ductless indoor unit DIRM-24HP-WM6 of 6 models have all five ratings · AHRI 20774372771.9(50 is the typical model of its size class)HO-SZ24-AB-Qwith ductless indoor unit HW-SZ24-AB-Q2 of 2 models have all five ratings · AHRI 211306396
Non-ducted, 2.5 to 3 tons83.4(50 is the typical model of its size class) (higher)DIRM-36HXPRO28-4Z7 of 9 models have all five ratings · AHRI 20774379177.3(50 is the typical model of its size class)HO-MQ36-AC-Q9 of 9 models have all five ratings · AHRI 213785768
Non-ducted, 3.5 to 4.5 tons78.0(50 is the typical model of its size class) (higher)DIRM-48HXPRO28-5Z3 of 4 models have all five ratings · AHRI 20774379473.9(50 is the typical model of its size class)HO-MP48-AB-Q4 of 4 models have all five ratings · AHRI 211306410

All-around board, every manufacturer

Standout model on each rating

Each manufacturer’s model that beats the largest share of comparable models on the rating; the higher share is in bold.
Top model per rating by peer percentile, with its AHRI-certified value and peer group
RatingDIRECT AIRMitsutomo
COP at 5°Fbeats 97% · 2.39DIRM-12DA25-1ZNon-ducted, up to 1.5 tonsbeats 87% · 2.01RO-SZ36-AB-QAlso listed as RO-SZ36-AC-QNon-ducted, 2.5 to 3 tons
Capacity retention at 5°Fbeats 93% · 107%DIRM-06HXPRO28-1ZNon-ducted, up to 1.5 tonsbeats 97% · 101%HO-MT28-AC-QDucted, 2.5 to 3 tons
HSPF2beats 99% · 13.6DIRM-06HXPRO28-1ZNon-ducted, up to 1.5 tonsbeats 99% · 10.3HO-SZ48-BB-QDucted, 3.5 to 4.5 tons
SEER2beats 99% · 20.9DIRM-48HXPRO28-5ZDucted, 3.5 to 4.5 tonsbeats 99% · 20.9HO-MP48-AB-QDucted, 3.5 to 4.5 tons
EER2beats 98% · 16.2DIRM-09HXPRO28-1ZNon-ducted, up to 1.5 tonsbeats 95% · 15.8HO-SZ09-AB-QNon-ducted, up to 1.5 tons
Heating capacity at 5°Fbeats 96% · 20,000 Btu/hDIRM-18HXPRO28-2ZNon-ducted, up to 1.5 tonsbeats 99% · 56,500 Btu/hHW-SZ60-BB-QNon-ducted, 3.5 to 4.5 tons

In the cold

NEEP cold-climate listings of both manufacturers against all listed models.
DIRECT AIR vs Mitsutomo: capacity and COP from 47°F downNEEP cold-climate listings at maximum capacity · 3,707 models (37.7% of the catalog) have ratings at 47, 17 and 5°F
  • All listed models (median, middle 50% and 80%)
  • DIRECT AIR (median, middle 50%)
  • Mitsutomo (median, middle 50%)
Heating capacity, % of its 47°F maximum69%72%COP at maximum capacity1.981.91

One curve per model: its NEEP-rated certification with the best 5°F COP. Every point of a curve is over the same models. 1 implausible NEEP points are left out. NEEP lists only models submitted to it, so this is a cold-climate-leaning subset, not the whole catalog.
Show the data as a table
All listed models: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,707100%100%100%100%100%
All rated models, 17°F3,70765%68%76%83%92%
All rated models, 5°F3,70755%58%67%75%83%
All listed models: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
All rated models, 47°F3,7072.642.873.13.323.53
All rated models, 17°F3,7071.982.052.22.342.49
All rated models, 5°F3,7071.81.831.922.032.21
DIRECT AIR: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
DIRECT AIR, 47°F43100%100%100%100%100%
DIRECT AIR, 17°F4367%70%74%80%85%
DIRECT AIR, 5°F4357%62%69%78%81%
DIRECT AIR: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
DIRECT AIR, 47°F432.762.873.043.253.52
DIRECT AIR, 17°F431.952.042.132.282.41
DIRECT AIR, 5°F431.831.871.982.082.2
Mitsutomo: capacity, % of its 47°F maximum
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsutomo, 47°F30100%100%100%100%100%
Mitsutomo, 17°F3070%75%80%85%93%
Mitsutomo, 5°F3057%65%72%81%83%
Mitsutomo: COP at maximum capacity
Scope, temperatureModels10th pct.25thMedian75th90th
Mitsutomo, 47°F302.642.792.993.213.45
Mitsutomo, 17°F301.92.052.152.232.34
Mitsutomo, 5°F301.81.841.9122.04

Source: NEEP ccASHP list · as of

More comparisons